L Rev. 01/06/00

Podobne dokumenty
L /2010 rev 0 CP.BULL8 OM UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2013 rev. 3 BRAINY UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2014 rev 1 HEADY 24 3B UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2011 rev 1 HEADY 24 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2011 rev. 0 CP.BISON OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2016 rev. 4 BRAINY UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

EN TABLE - TABLE 2-2: PHOTOCELL ADDRESSES

L /2016 rev 6 HEADY UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev. 2 CP.BISON OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2014 rev.1 CP.BISON 35 OTI L UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2013 rev.4 CP.BISON OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

CP.B24ESA CP.B1024ESA

L /2017 rev 0 BULL 624 TURBO EN UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Deklaracja zgodności

BULL 1524 BULL 1524.S

L /2016 rev 1 EVA.7 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2016 rev 2 EVA.5 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Deklaracja Zgodności WE

Deklaracja Zgodności WE

L /2016 rev 3 EVA.7 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Instrukcja Montażu. Zawór elektromagnetyczny. Zawór kontrolny. Zawór odcinający. Krańcówka. Wkład filtracyjny EB-PS300=A

DM-ML, DM-FL. Auxiliary Equipment and Accessories. Damper Drives. Dimensions. Descritpion

DA.24V CP.EVA. L Rev. 09/08/06 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE COMMANDE CENTRAL DE MANDO CENTRALKA STEROWANIA

Przeciwpożarowe sterowniki dla bram zwijanych, sekcyjnych i przesuwnych. Fire-proof controls for roller shutters, sectional doors and sliding gates

DA.24V. L Rev. 03/05/01 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE COMMANDE CENTRAL DE MANDO CENTRALKA STEROWANIA

Céliane TM Vac 50-60Hz. 1 x 2.5 mm 2 2 x 1.5 mm 2. Max. 400 W 400 W 400 VA 400 VA. 240 Vac. Min. 40 W 40 W 40 VA 40 VA

Kamera Yale Wi-Fi Full HD 4MP

L /2013 rev 4 KER UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Z E R T I F I K A T. H. Büteführ u. Sohn GmbH & Co. KG

START L Rev. 03/07/03 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE COMMANDE CENTRAL DE MANDO CENTRALKA STEROWANIA

Terraneo cm PART. T8879C_PL. ø 5 mm. Istruzioni d uso Instructions for use 07/07-01 PC. Pulsanti programmabili (O-1-2-3)

POPRAWKA do POLSKIEJ NORMY PN-EN : /AC

Wyroby medyczne Systemy zarządzania jakością Wymagania do celów przepisów prawnych

Montageanleitung Automatische Verriegelung Assembly Instructions - Automatic Locking Instrukcja Montażu - Zamknięcie Automatyczne

LED PAR 56 7*10W RGBW 4in1 SLIM

Rev Źródło:

RE11RMMU przekaźnik czasowy opóźniający 10-funkcyjny - 1 s..100 h V AC - 1 OC

Wymagania bezpieczeństwa dotyczące elektrycznych przyrządów pomiarowych, automatyki i urządzeń laboratoryjnych Część 1: Wymagania ogólne

Instrukcja Montażu. Zawór pilotowy. Zawór przełączający 3-drogowy. Zawór odcinający. Wkład filtrujący. Zawór iglicowy EB-FD300=A

B IURO B ADAWCZE DS. J AKOŚCI

1 O PART. U0557B_PL 06/ AP cm

Instrukcja obsługi User s manual

ORIGINAL USER MANUAL. Remote Control Z-Wave NC 896-GB IU/ZRH12/ /F

[ROBOKIDS MANUAL] ROBOROBO


/2004 RENAULT MEGAN SCENIC I R/011. Cat. No. e20. e20*94/20*0680*00 D = 7,72kN. 1400Kg 75Kg. D (kn) = x 0, MAX kg.

Camspot 4.4 Camspot 4.5

LCD (Liquid Crystal Display)

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

Installation of EuroCert software for qualified electronic signature

KWS. Instrukcja obsługi User's manual Manuel d utilisation Руководство по эксплуатации RMSI25, RMSI63

DEKLARACJA ZGODNOŚCI CE

PRZEKRÓJ A-A. The clearance specified in appendix VII, diagram 25a/b of Regulation No UN EU must be guaranteed at laden weight of the vehicle.

Aktualizacja Oprogramowania Firmowego (Fleszowanie) Microprocessor Firmware Upgrade (Firmware downloading)

DICHIARAZIONE DI CONFORMITA DECLARATION OF CONFORMITY

Pinze di presa per wafer SWGm

WYŁĄCZNIK CZASOWY OUTDOOR TIMER


TACHOGRAPH SIMULATOR DTCOSIM

Rev Źródło:

Wyroby medyczne Systemy zarządzania jakością Wymagania do celów przepisów prawnych

POPRAWKA do POLSKIEJ NORMY PN-EN 16005: /AC. Drzwi z napędem Bezpieczeństwo użytkowania Wymagania i metody badań

FOREST DIAMOND Pilot radiowy X460

Einbau von Rauchwarnmeldern nach DIN 14676

BLACKLIGHT SPOT 400W F

Realizacja systemów wbudowanych (embeded systems) w strukturach PSoC (Programmable System on Chip)

Steuerberaterin Ria Franke

Zmiany techniczne wprowadzone w wersji Comarch ERP Altum

RE7MA13BU przekaźnik symetryczny z opóźn. zał i wył - 0, s 24 V AC DC-2 styki przeł.

BN1520 BN1521 BN1522 FAMOR S.A. ROZDZIELNICA ŒWIATE NAWIGACYJNYCH I SYGNALIZACYJNYCH NAVIGATION AND SIGNAL LIGHT CONTROL PANELS EDITION 07/04

RE8RA11B przemysłowy przekaźnik czasowy s - typ C - 24 V AC/DC - 1 Z/O

POPRAWKA do POLSKIEJ NORMY PN-EN : /AC

VW3A7703 Akcesoria VW3A Rezystor hamowania IP20 28 Ohm 200W

Gruntowa Pompa Ciepła Bezpośredniego Odparowania DXW

DC UPS. User Manual. Page 1

Installation Guide Einbauanleitung Guide d'installation Guida all installazione Guía de instalación Instrukcja montażu

OSTC GLOBAL TRADING CHALLENGE MANUAL

Wysokonapięciowa aparatura rozdzielcza i sterownicza Część 100: Wyłączniki wysokiego napięcia prądu przemiennego

DEKLARACJA ZGODNOŚCI CE

Hippo Boombox MM209N CD. Instrukcja obsługi User s Manual

DEKLARACJA ZGODNOŚCI CE

deep learning for NLP (5 lectures)

Strona główna > Produkty > Systemy regulacji > System regulacji EASYLAB - LABCONTROL > Program konfiguracyjny > Typ EasyConnect.

MM210. Instrukcja obsługi User s Manual

OPBOX ver USB 2.0 Mini Ultrasonic Box with Integrated Pulser and Receiver

Helena Boguta, klasa 8W, rok szkolny 2018/2019

Moduł 4 przekaźników sterowanych RS485

LED PAR 56 7x10 4in1 RGBW F

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

Instrukcja konfiguracji usługi Wirtualnej Sieci Prywatnej w systemie Mac OSX

Zasady bezpieczeństwa

Installez un certificat ssl par l'intermédiaire du CLI sur un ESA


LED WASHER 30x3W WHITE IP65 F

DEKLARACJA ZGODNOŚCI CE

AJ-SYB007X AJ-SYB008X

Rev Źródło:

Kontrolery LC, CVS, AE-N, SS-N, SQ-N, SQP-N, SMC, AMC Controllers LC, CVS, AE-N,SS-N, SQ-N, SQP-N, SMC, AMC

250 W 250 W. 250 W min W min -1 (1.1 A) S A R 63 min -1. Podłączenie. \Connection\

OpenPoland.net API Documentation

Transkrypt:

L8542867 Rev. 01/06/00 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE COMMANDE CENTRAL DE MANDO CENTRALKA STEROWANIA Libro istruzioni Operating instructions Betriebsanleitung Livret d instructions Manual de instrucciones Książeczka z instrukcjami UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE, SERRANDE ED AFFINI

Dichiarazione CE di conformità EC declaration of confirmity EG-Konformitatserklarung Déclaration CE de conformité Declaracion CE de conformidad Deklaracja UE o zgodności Con la presente dichiariamo che il nostro prodotto We hereby declare that our product Hiermit erklaren wir, dass unser Produkt Nous déclarons par la présente que notre produit Por la presente declaramos que nuestro producto Niniejszym oświadczamy że nasz produkt BRAIN 24 è conforme alle seguenti disposizioni pertinenti: complies with the following relevant provisions: folgenden einschlagigen Bestimmungen entspricht: correspond aux dispositions pertinentes suivantes: satisface las disposiciones pertinentes siguientes: zgodny jest z poniżej wyszczególnionymi rozporządzeniami: Direttiva sulla compatibilità elettromagnetica (89/336/CCE, 93/68/CEE) EMC guidelines (89/336/EEC, 93/68/EEC) EMV-Richtlinie (89/336/EWG, 93/68/EWG) Directive EMV (89/336/CCE, 93/68/CEE) (Compatibilité électromagnétique) Reglamento de compatibilidad electromagnética (89/336/MCE, 93/68/MCE) Wytyczna odnośnie zdolności współdziałania elektromagnetycznego (89/336/EWG, 93/68/EWG) Direttiva sulla bassa tensione (73/23/CEE, 93/68/CEE) Low voltage guidelines (73/23/EEC, 93/68/EEC) Tiefe Spannung Richtlinie (73/23/EWG, 93/68/EWG) Directive bas voltage (73/23/CEE, 93/68/CEE) Reglamento de bajo Voltaje (73/23/MCE, 93/68/MCE) Wytyczna odnośnie niskiego napięcia (73/23/EWG, 93/68/EWG) Benincà Luigi, Responsabile legale. Sandrigo, 05/10/2005. Automatismi Benincà SpA Via Capitello, 45 36066 Sandrigo (VI) ITALIA

LAMP 24Vdc Lock 12Vac 10W (+) (-) 24Vdc 500mA max COM SWO1 SWC1 SWO2 SWC2 PHOT PHOTC STOP OPEN CLOSE PED P.P. COM M1 M2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DAS J1 DAS Open DAS N.C. 26 27 SCA 24Vdc 3W max Service Light 230V 2ϒ ch RADIO J1 DAS Close DAS 8K2 8 9 10 11 12 13 8 9 10 11 8 9 10 11 90s 2ch:Off 2ch:On SERL:On LED RADIO - + F1 T 2A 30 31 ANT SHIELD 24Vac/24Vdc ANT DAS 8k2 26 27 3

Collegamento scheda CB.24V (opzionale) Connection to the CB.24V Card (optional) Anschluss Karte CB.24V (Option) Branchement fiche CB.24V (optionnel) Conexión tarjeta CB.24V (opcional) Połączenie karty CB.24V (opcjonalna) 4

Centrale di comando BRAIN 24 La centrale elettronica BRAIN 24 può essere utilizzata per il controllo di 1 o 2 motori 24Vdc con potenza non superiore a 80W+80W. AVVERTENZE GENERALI a) L installazione elettrica e la logica di funzionamento devono essere in accordo con le normative vigenti. b) I conduttori alimentati con tensioni diverse, devono essere fisicamente separati, oppure devono essere adeguatamente isolati con isolamento supplementare di almeno 1 mm. c) I conduttori devono essere vincolati da un fissaggio supplementare in prossimità dei morsetti. d) Ricontrollare tutti i collegamenti fatti prima di dare tensione. e) Gli ingressi N.C. non utilizzati devono essere ponticellati. N Morsetti Funzione Descrizione FUNZIONI INGRESSI/USCITE Centrale BRAIN 24 1-2 Motore 1 Collegamento motore 1: 24Vdc 80W max 3-4 Motore 2 Collegamento motore 2: 24Vdc 80W max 5-6 Lampeggiante Collegamento lampeggiante 24Vdc 15W max. 7-8 Lock Uscita alimentazione 12Vac/10W per elettroserratura (7:0V, 8:+12V) 9-10 SCA/2 Ch radio Contatto pulito N.O. Controllato dalla logica 2Ch. Con logica 2ch Off: Contatto SCA spia cancello aperto. Con logica 2ch On: Contatto controllato dal 2 canale radio della ricevente. Nota: con logica SRL :On, svolge la funzione contatto per comando luce di cortesia, vedi tabella logiche. 11-12 24 Vdc Uscita alimentazione accessori 24Vdc/0,5A max. (11:+, 12:-) 13 COM Comune per finecorsa e tutti gli ingressi di comando. 14 SWO1 Ingresso finecorsa APRE motore 1 (contatto N.C.) 15 SWC1 Ingresso finecorsa CHIUDE motore 1 (contatto N.C.) 16 SWO2 Ingresso finecorsa APRE motore 2 (contatto N.C.) 17 SWC2 Ingresso finecorsa CHIUDE motore 2 (contatto N.C.) 18 PHOT Ingresso fotocellula attiva in apertura e chiusura 19 PHOT C Ingresso fotocellula attiva solo in chiusura 20 STOP Ingresso pulsante STOP (contatto N.C.) 21 OPEN Ingresso pulsante APRE (contatto N.O.). 22 CLOSE Ingresso pulsante CHIUDE (contatto N.O.) 23 PED Ingresso pulsante pedonale (contatto N.O.), comanda l apertura completa del motore 1 24 Passo-Passo Ingresso pulsante passo-passo (contatto N.O.) 25 COM Comune per tutti gli ingressi di comando. 26-27 BAR Ingresso contatto costa sensibile Costa resistiva: Jumper DAS chiuso Costa meccanica: Jumper DAS aperto L intervento della costa arresta il movimento dell anta e inverte per circa 3s. 30-31 Antenna Collegamento antenna scheda radioricevente ad innesto (30-segnale/31-schermo). JF1-JF2 24Vac/dc Ingresso alimentazione 24Vac/24Vdc dal secondario del trasformatore. Nel caso di utilizzo di batterie tampone collegare la scheda CB.24V (opzionale) come indicato nella schema. Programmazione La programmazione delle varie funzionalità della centrale viene effettuata utilizzando il display LCD presente a bordo della centrale ed impostando i valori desiderati nei menu di programmazione descritti di seguito. Il menu parametri consente di impostare un valore numerico ad una funzione, in modo analogo ad un trimmer di regolazione. Il menu logiche consente di attivare o disattivare una funzione, in modo analogo al settaggio di un dip-switch. Altre funzioni speciali seguono i menu parametri e logiche e possono variare a seconda del tipo di centrale o revisione software. 5

Per accedere alla programmazione: 1 - Premere il pulsante <PG>, il display si porta nel primo menu Parametri PAR. 2 - Scegliere con il pulsante <+> o <-> il menu che si intende selezionare (PAR>>LOG>>RADIO>>NMAN>>RES>>PAR>>...). 3- Premere il pulsante <PG>, il display mostra la prima funzione disponibile nel menu. 4 - Scegliere con il pulsante <+> o <-> la funzione che si intende modificare. 5 - Premere il pulsante <PG>, il display mostra il valore attualmente impostato per la funzione selezionata. 6 - Selezionare con il pulsante <+> o <-> il valore che si intende assegnare alla funzione. 7 - Premere il pulsante <PG>, il display mostra il segnale PRG che indica l avvenuta programmazione. Note: La pressione simultanea di <+> e <-> effettuata all interno di un menu funzione consente di tornare al menu superiore senza apportare modifiche. La pressione simultanea di <+> e <-> effettuata a display spento visualizza la versione software della scheda. Mantenere la pressione sul tasto <+> o sul tasto <-> per accelerare l incremento/decremento dei valori. Dopo un attesa di 60s la centrale esce dalla modalità programmazione e spegne il display. Parametri, Logiche e Funzioni Speciali Nelle tabelle di seguito vengono descritte le singole funzioni disponibili nella centrale. MENU FUNZIONE Valori impostabili MIN-MAX-(Default) MEMO TCA Tempo di chiusura automatica. Attivo solo con logica TCA =ON. Al termine del tempo impostato la centrale comanda una manovra di chiusura. 1-240-(40s) TM1 Tempo lavoro motore 1. Regola il tempo di funzionamento a velocità normale durante la fase di apertura e chiusura del motore 1. Vedi paragrafo Regolazione rallentamento. 5-180-(9s) TM2 Tempo lavoro motore 2. Regola il tempo di funzionamento a velocità normale durante la fase di apertura e chiusura del motore 2. Vedi paragrafo Regolazione rallentamento. 5-180-(9s) PMo1 Regola la coppia applicata al motore 1 durante la fase di apertura. * 1-99-(50%) PMC1 Regola la coppia applicata al motore 1 durante la fase di chiusura.* 1-99-(50%) PARAMETRI PMo2 Regola la coppia applicata al motore 2 durante la fase di apertura.* 1-99-(50%) PMc2 Regola la coppia applicata al motore 2 durante la fase di chiusura.* 1-99-(50%) TDMo TDMC TLOc Tempo ritardo apertura Mot.2 Regola il tempo di ritardo in apertura del motore 2 rispetto al motore 1 Tempo ritardo chiusura Mot.1 Regola il tempo di ritardo in chiusura del motore 1 rispetto al motore 2 Tempo attivazione elettroserratura. Se non si utilizza elettroserratura portare il parametro al valore 0. 0-15-(2s) 0-40-(3s) 0-5-(3s) SLDS Pso1 Psc1 Pso2 Psc2 Regola la velocità del motore durante le fasi di rallentamento. Valore espresso in percentuale rispetto alla velocità di normale funzionamento. Regola la coppia applicata al motore 1 durante la fase di rallentamento in chiusura* Regola la coppia applicata al motore 1 durante la fase di rallentamento in apertura* Regola la coppia applicata al motore 2 durante la fase di rallentamento in chiusura* Regola la coppia applicata al motore 2 durante la fase di rallentamento in apertura* 30-99 (30) 1-99-(50%) 1-99-(50%) 1-99-(50% 1-99-(50% * ATTENZIONE: Un errata impostazione di questi parametri può risultare pericolosa. Rispettare le normative vigenti! Regolazione rallentamento Con rallentamento abilitato (logica SLD:ON), al termine del tempo impostato con TM1 e TM2, inizia la fase di rallentamento. Il tempo impostato deve pertanto essere minore dell effettiva corsa dell automatismo. Ad es. con una corsa di 20s, impostare 17s per iniziare la fase di rallentamento con 3s di anticipo rispetto al termine della manovra. Nota: I parametri TM1 e TM2 sono inifluenti con rallentamento disabilitato (logica SLD:OFF), dato che il termine della manovra viene determinato esclusivamente dall intervento del finecorsa o del sensore amperometrico. La velocità del motore durante la fase di rallentamento è determinata dal valore del parametro SLDS 6

MENU FUNZIONE Valori impostabili ON-OFF-(Default) MEMO TCA Abilita o disabilita la chiusura automatica Off: chiusura automatica disabilitata On: chiusura automatica abilitata (ON) IbL Abilita o disabilita la funzione condominiale. Off: funzione condominiale disabilitata. On: funzione condominiale abilitata. L impulso P.P. o del trasmettitore non ha effetto durante la fase di apertura. SCL Abilita o disabilita la chiusura rapida On: chiusura rapida abilitata. Con cancello aperto o in fase di apertura l intervento della fotocellula provoca la chiusura automatica dopo 3 s. Attiva solo con TCA:ON Off: chiusura rapida disabilitata. Sld Abilita o disabilita il rallentamento. Off: Rallentamento escluso. On: Rallentamento attivo. PP Seleziona la modalità di funzionamento del Pulsante P.P. e del trasmettitore. Off: Funzionamento: APRE > STOP > CHIUDE > STOP > On: Funzionamento: APRE > CHIUDE > APRE > LOGICHE PRE BLC Abilita o disabilita il pre-lampeggio. Off: Pre-lampeggio disabilitato. On: Pre-lampeggio abilitato. Il lampeggiante si attiva 3s prima della partenza del motore. Abilita o disabilita la funzione di blocco. Off: Funzione blocco disabilitato. On: Funzione blocco abilitato. Dopo l intervento dei finecorsa di chiusura la centrale ritarda l arresto di circa 0,5s, in modo da consentire una migliore battuta dell anta sui fermi di arresto. (ON) CLOC Seleziona la modalità dell ingresso APRE Off: Ingresso APRE con funzionalità APRE On: Ingresso APRE con funzionalità OROLOGIO. Da utilizzare per collegamento a temporizzatore per apertura/chiusura a tempo. (Contatto CHIUSO- cancello aperto, Contatto aperto, funzionamento normale). htr Abilita o disabilita la funzione Uomo presente. Off: Funzionamento automatico. On: Funzionamento Uomo Presente. La pressione dei pulsanti APRE/CHIUDE deve essere mantenuta durante tutta la manovra. mloc Seleziona il tipo di elettroserratura utilizzato. Off: Elettroserratura a scatto, normalmente non alimentata. Prima di ogni manovra di apertura viene fornita alimentazione a 12Vac per il tempo impostato dal parametro TLOC. On: Elettroserratura magnetica, normalmente alimentata a 12Vac. Prima di ogni manovra di apertura viene tolta alimentazione per il tempo impostato dal parametro TLOC. 1mot Seleziona la modalità di funzionamento 1/2 motori: Off: Entrambi i motori attivi. On: Attivo solo il motore 1. 7

MENU FUNZIONE Valori impostabili ON-OFF-(Default) MEMO Cvar Abilita o disabilita i trasmettitori a codice programmabile. On: Ricevitore radio abilitato esclusivamente ai trasmettitori a codice variabile (rolling-code). Off: Ricevitore abilitato a trasmettitori codice variabile (rolling-code) e programmabile (autoapprendimento e dip/switch). LOGICHE NOlS 2Ch Seleziona la modalità di funzionamento del sensore amperometrico in presenza o assenza dei finecorsa. Off: Finecorsa presenti. L intervento del sensore amperometrico viene interpretato dalla centrale come presenza di ostacolo sul movimento dell anta. Viene quindi comandato l arresto e l inversione per circa 3s, in modo analogo all intervento della costa. On: Finecorsa assenti. L intervento del sensore amperometrico viene interpretato dalla centrale come finecorsa. Viene quindi comandato l arresto del movimento. Nota: Chiudere i contatti dei finecorsa con dei ponticelli se si desidera utilizzare questa funzione. Seleziona il comportamento dell uscita ai morsetti 9-10: On:.L uscita ha la funzione 2 canale radio: il contatto, normalmente aperto, commuta per 1s alla ricezione di un comando radio assegnato al 2 canale radio. Vedi menu radio. Off: L uscita ha la funzione SCA, spia cancello aperto: contatto aperto ad anta chiusa, intermittente durante il movimento dell anta, contatto chiuso ad anta aperta. Vedi schema di collegamento. serl Abilita o disabilita la funzione luce di servizio sull uscita 9-10. On: ad ogni manovra il contatto viene chiuso per circa 90s, indipendentemente dalla configurazione del parametro 2ch. Utilizzare un relè ausiliario per il comando della luce. Off: Il comportamento dell uscita è impostato dal parametro 2ch, vedi parametro precedente. MENU FUNZIONE PP Selezionando questa funzione la ricevente si pone in attesa (Push) di un codice trasmettitore da assegnare alla funzione passo-passo. Premere il tasto del trasmettitore che si intende assegnare a questa funzione. Se il codice è valido, viene memorizzato e viene visualizzato il messaggio OK Se il codice non è valido, viene visualizzato il messaggio Err. RADIO 2ch CLr Selezionando questa funzione la ricevente si pone in attesa (Push) di un codice trasmettitore da assegnare al secondo canale radio, sui morsetti 9-10. La logica 2ch deve essere ON, la logica SERL deve essere OFF. Premere il tasto del trasmettitore che si intende assegnare a questa funzione. Se il codice è valido, viene memorizzato e viene visualizzato il messaggio OK Se il codice non è valido, viene visualizzato il messaggio Err. Selezionando questa funzione la ricevente si pone in attesa (Push) di un codice trasmettitore da cancellare dalla memoria. Se il codice è valido, viene cancella to e viene visualizzato il messaggio OK Se il codice non è valido o non è presente in memoria, viene visualizzato il messaggio Err RTR Cancella completamente la memoria della ricevente. Viene richiesta conferma dell operazione. 8 MENU NMAN RES FUNZIONE Visualizza il numero di cicli completi (apre+chiude) effettuate dall automazione. La prima pressione del pulsante <PG>, visualizza le prime 4 cifre, la seconda pressione le ultime 4. Es. <PG> 0012 >>> <PG> 3456: effettuati 123.456 cicli. RESET della centrale. ATTENZIONE!: Riporta la centrale ai valori di default. La prima pressione del pulsante <PG> provoca il lampeggio della scritta RES, una ulteriore pressione del pulsante <PG> effettua il reset della centrale. Nota: Non vengono cancellati i trasmettitori dalla ricevente. Esempio programmazione Supponiamo sia necessario: - impostare un tempo di chiusura automatica (TCA) di 100s - attivare il prelampeggio eseguire passo a passo le operazioni descritte di seguito:

Passo Premere Display Note 1 PAR Primo menu 2 TCA Prima funzione del primo menu 3 040 Valore attualmente impostato per la funzione selezionata 4 100 Settare con i tasti <+> e <-> il valore desiderato 5 PRG Il valore viene programmato TCA Effettuata la programmazione, il display si riporta alla funzione appena settata 6 PAR Premere simultaneamente <+> e <-> per spostarsi al menu superiore 7 Log Secondo menu 8 TCA Prima funzione del secondo menu 9 Pre Premere più volte <-> fino a selezionare la logica PRE 10 OFF Valore attualmente impostato per la funzione selezionata 11 ON Settare con i tasti <+> e <-> il valore desiderato 12 PRG Il valore viene programmato Pre Effettuata la programmazione, il display si riporta alla funzione appena settata 13 PAR Premere simultaneamente <+> e <-> per tornare al menu superiore e uscire dalla programmazione o attendere 30s. Diagnostica Nel caso di anomalie di funzionamento è possibile visualizzare, premendo il tasto + o -, lo stato di tutti gli ingressi (finecorsa, comando e sicurezza). Ad ogni ingresso è associato un segmento del display che in caso di attivazione si accende, secondo il seguente schema. Gli ingressi N.C. sono rappresentati dai segmenti verticali. Gli ingressi N.O. sono rappresentati dai segmenti orizzontali. Ad esempio, con le ante in completa chiusura la visualizzazione è la seguente: nel momento in cui viene dato un impulso Open: durante la fase di apertura: con le ante in completa apertura: 9

BRAIN 24 control unit The BRAIN 24 electronic control unit may be used for the control of 1 or 2 motors 24Vdc with power not higher than 80W+80W. GENERAL WARNINGS a) The electrical installation and the operating logic must comply with the regulations in force. b) The leads fed with different voltages must be physically separate, or they must be suitably insulated with additional insulation of at least 1 mm. c) The leads must be secured with an additional fixture near the terminals. d) Check all the connections again before switching on the power. e) The unused N.C. inputs must be bridged. Terminal No. Function Description INPUT/OUTPUT FUNCTIONS BRAIN 24 Control unit 1-2 Motor 1 Connection, motor 1: 24VDC 80W max 3-4 Motor 2 Connection, motor 2: 24VDC 80W max 5-6 Flashing light Connection, flashing light 24VDC 15W max. 7-8 Lock Output, 12VAC/10W power supply for electric lock (7:0V, 8:+12V) 9-10 SCA/2 Ch radio Normally open clean contact. Controlled by 2Ch logic. With 2ch logic Off: SCA contact, open gate indicator. With 2ch logic On: Contact controlled by 2 nd radio channel of the receiver. Note: with SRL logic On, it performs the contact function of the courtesy light control, see table of logic. 11-12 24 VDC Output, accessory power supply, 24VDC/0.5A max. (11:+, 12:-) 13 COM Common for limit switches and all control inputs. 14 SWO1 Input, OPEN limit switch, motor 1 (Normally closed contact) 15 SWC1 Input, CLOSE limit switch, motor 1 (Normally closed contact) 16 SWO2 Input, OPEN limit switch, motor 2 (Normally closed contact) 17 SWC2 Input, CLOSE limit switch, motor 2 (Normally closed contact) 18 PHOT Input, photocell activated in both opening and closing phases 19 PHOT C Input, photocell activated in closing phase only 20 STOP Input, STOP push-button (Normally closed contact) 21 OPEN Input, OPEN push-button (Normally open contact). 22 CLOSE Input, CLOSE push-button (Normally open contact) 23 PED Input, push-button for pedestrian use (Normally open contact), it controls the complete opening of motor 1 24 Step-by-Step Input, step-by-step push button (Normally open contact) 25 COM Common for all control inputs. 26-27 BAR Input, sensitive edge contact Resistive edge: DAS Jumper closed Mechanical edge: DAS Jumper open When the edge is activated, the gate movement is stopped and reversed for about 3s. 30-31 Antenna Connection to the insertable radio receiver card (30-signal/31-screen). JF1-JF2 24VAC/dc Input, 24VAC/24VDC power supply from the secondary of the transformer. If buffer batteries are used, connect the CB.24V card (in option) as indicated in the table. Programming The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the desired values in the programming menus described below. The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer. The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch. Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software release. 10

To access programming: 1 Press the button <PG>, the display goes to the first menu, Parameters PAR. 2 With the <+> or <-> button, select the menu you want (PAR>>LOG>>RADIO>>NMAN>>RES>>PAR>>...). 3- Press the button <PG>, the display shows the first function available on the menu. 4 - With the <+> or <-> button, select the function you want. 5 - Press the button <PG>, the display shows the value currently set for the function selected. 6 - With the <+> or <-> button, select the value you intend to assign to the function. 7 - Press the button <PG>, the display shows the signal PRG which indicates that programming has been completed. Notes: Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any changes. Simultaneously pressing <+> and <-> when the display is switched off shows the card software release. Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values. After waiting 60s the control unit quits programming mode and switches off the display. Parameters, Logic and Special Functions The tables below describe the individual functions available in the control unit. MENU FUNCTION TCA Automatic closing time. Active only with logic TCA =ON. At the end of the set time the control unit orders a closing manoeuvre. Settable values MIN-MAX-(Default) 1-240-(40s) MEMO TM1 TM2 Operating time, motor 1. The operating time is adjusted at normal speed during motor 1 opening and closing phases. See section Adjustment of braking. Operating time, motor 2. The operating time is adjusted at normal speed during motor 2 opening and closing phases. See section Adjustment of braking. 5-180-(9s) 5-180-(9s) PMo1 The torque applied to motor 1 during the opening phase is adjusted. * 1-99-(50%) PMC1 The torque applied to motor 1 during the closing phase is adjusted.* 1-99-(50%) PARAMETERS PMo2 The torque applied to motor 2 during the opening phase is adjusted.* 1-99-(50%) PMc2 The torque applied to motor 2 during the closing phase is adjusted.* 1-99-(50%) TDMo TDMC TLOc Mot.2 opening delay time. Regulates the delay time of motor 2 on opening with respect to motor 1 Mot.1 closing delay time Regulates the delay time of motor 1 on closing with respect to motor 2 Electric lock activation time. If the electric lock is not used, set the parameter at 0. 0-15-(2s) 0-40-(3s) 0-5-(3s) SLDS Pso1 Psc1 Pso2 Psc2 The motor speed during braking is adjusted. The value is expressed in percentage with respect to speed during normal operation. The torque applied to motor 1 during braking in the closing phase is adjusted * The torque applied to motor 1 during braking in the opening phase is adjusted * The torque applied to motor 2 during braking in the closing phase is adjusted * The torque applied to motor 2 during braking in the opening phase is adjusted * 30-99-(30) 1-99-(50%) 1-99-(50%) 1-99-(50%) 1-99-(50%) * WARNING: An incorrect setting of these parameters may result in an hazard. Comply with regulations in force! Adjustment of braking With braking enabled (SLD logic: ON), braking will start at end of time preset with TM1 and TM2. The preset time should therefore be lower than the real stroke of the operator. For example, with a 20s stroke, preset 17s to start the braking phase, 3s in advance with respect to end of movement. Note: The TM1 and TM2 parameters do not work with braking disabled (SLD logic: OFF), as the end of operation is determined only by the triggering of the limit switch or by the amperometric sensor. The speed of the motor during braking is determined by the SLDS parameter value. 11

MENU FUNCTION Settable values ON-OFF-(Default) MEMO TCA Enables or disables automatic closing Off: automatic closing disabled On: automatic closing enabled (ON) IbL Enables or disables condominium function. Off: condominium function disabled. On: condominium function enabled. The step-by-step impulse or transmitter impulse has no effect during the opening phase. SCL Enables or disables rapid closing On: rapid closing enabled. With the gate open or in the opening phase the intervention of the photocell causes automatic closing after 3 s. Active only with TCA:ON. Off: rapid closing disabled. Sld Enables or disables slowing. Off: Slowing excluded. On: Slowing active. PP Selects the operating mode of the Step by step button and of the transmitter. Off: Operation: OPEN > STOP > CLOSE > STOP > On: Operation: OPEN > CLOSE > OPEN > LOGIC PRE Blc Enables or disables pre-blinking. Off: Pre-blinking disabled. On: Pre-blinking enabled. Blinking is activated 3s before the motor starts. The lock function is enabled or disabled. Off: Lock function disabled. On: Lock function enabled. After the activation of closure limit switches the control unit delays the stop by approx. 0.5s in order to allow a better resting of the gate against the stoppers. (ON) CLOC Selects the mode of the OPEN input Off: OPEN input with OPEN function On: OPEN input with CLOCK function. To be used for connection to a timer for timed opening/closing. (Contact CLOSED- gate open, Contact open, normal operation). htr Enables or disables Man present function. Off: Automatic operation. On: Man Present operation. The OPEN/CLOSE buttons must be held down during the whole manoeuvre. mloc Selects the type of electric lock used. Off: Electric lock with latch, normally not fed. Before each opening manoeuvre power is fed at 12Vac for the time set by the parameter TLOC. On: Magnetic electric lock, normally fed at 12Vac. Before each opening manoeuvre the power supply is interrupted for the time set by the parameter TLOC. 1mot Select the 1/2 motors operating mode: Off: Both motors operating. On: Only motor 1 operating. 12

MENU FUNCTION Settable values ON-OFF-(Default) MEMO Cvar The code programmable transmitters is enabled or disabled. On: Radio receiver enabled only for rolling-code transmitters. Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning and Dip Switch). OFF LOGIC NOlS 2Ch The operation mode of the amperometric sensor is selected either the limit switches are provided or not. Off: Limit switches provided. The amperometric sensor activation is interpreted by the control unit as obstacle present in the gate movement area. Similarly to the safety edge activation, the control signal is sent to stop and reverse movement for approx. 3s. On: Limit switches not provided. The amperometric sensor activation is interpreted by the control unit as limit switch. The control signal is sent to stop the movement. Note: To use this function, close the limit switch contacts with jumpers. The output performance at Terminals 9-10: On: The output has the function of 2 nd radio channel: the normally open contact switches for 1s at reception of a radio control assigned to the 2 nd radio channel. See radio menu. Off: The output has the SCA function, open gate LED: open contact with closed gate, flashing light during gate movement, closed contact with open gate. See wire diagram. serl Service light function is enabled or disabled on output 9-10. On: at each movement, the contact is closed for approx. 90s, regardless of the configuration of 2ch parameter. For the light control use the auxiliary relay. Off: The performance of the output is preset by 2ch parameter, see previous parameter. MENU FUNCTION PP By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the stepby-step function. Press the transmitter key to be assigned to this function. If the code is valid, it is stored in memory and OK appears. If the code is not valid, the wording Err is displayed. RADIO 2ch By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the second radio channel, on Terminals 9-10. The 2ch logic must be ON, the SERL logic must be OFF. Press the transmitter key to be assigned to this function. If the code is valid, it is stored in memory and OK appears. If the code is not valid, the wording Err is displayed. CLr RTR By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory. If the code is valid, it is erase and OK appears. If the code is not valid or is not in memory, the wording Err is displayed. Completely erase the receiver memory. Confirmation of operation is required. MENU NMAN RES FUNCTION Displays the number of complete cycles (open+close) carried out by the automation. When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>> <PG> 3456: made 123.456 cycles. RESET of the control unit. ATTENTION!: Returns the control unit to the default values. Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The transmitter codes are not erased from the receiver. Let us suppose it is necessary to: - set an automatic closing time (TCA) of 100s - activate pre-blinking Perform the operations described below step by step: Example of programming 13

Step Press Display Notes 1 PAR First menu 2 TCA First function of the first menu 3 040 Value currently set for the function selected 4 100 Set the desired value with the <+> and <-> keys 5 PRG The value is programmed TCA When programming has been made, the display goes to the function just set 6 PAR Press <+> and <-> simultaneously to go to the higher menu 7 Log Second menu 8 TCA First function of the second menu 9 Pre Press <-> several times to select PRE logic 10 OFF Value currently set for the function selected 11 ON Set the desired value with the <+> and <-> keys 12 PRG The value is programmed Pre When programming has been made, the display goes to the function just set 13 PAR Press <+> and <-> simultaneously to go to the higher menu and quit programming or wait 30s. Diagnostics In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be displayed. One segment of the display is linked to each input. In the event of failure it switches on according to the following scheme. N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the horizontal segments. For example, with the leaves completely closed the display is as follows: the moment an Open impulse is given: during the opening phase: with the leaves completely open: 14

Steuerzentrale BRAIN 24 Die elektronische Steuerzentrale BRAIN 24 kann 1 oder 2 Motoren mit einer Leistung bis max. 80W+80W steuern. ALLGEMEINE HINWEISE a) Die Elektroinstallation und die Funktionslogik müssen den einschlägigen Normen entsprechen. b) Verschiedene Spannungen führende Leiter müsse physisch getrennt oder mit einer zusätzlichen Isolierung von mindestens 1 mm versehen sein. c) In der Nähe der Klemmen müssen die Leiter zusätzlich fixiert werden. d) Vor dem Zuschalten der Spannung alle Anschlüsse nochmals prüfen. e) Die nicht verwendeten, normalerweise geschlossenen Eingänge müssen überbrückt werden. Klemme Nr. Funktion Beschreibung FUNKTIONEN DER EIN-/AUSGÄNGE Zentrale BRAIN 24 1-2 Motor 1 Anschluss Motor 1: 24Vdc 80W max. 3-4 Motor 2 Anschluss Motor 2: 24Vdc 80W max. 5-6 Blinkleuchte Anschluss Blinkleuchte 24Vdc 15W max. 7-8 Lock Ausgang Speisung 12Vac/10W für Elektroschloss (7:0V, 8:+12V) 9-10 SCA/2 Ch Funk Reiner Kontakt N.O. Durch die Logik 2Ch gesteuert. Mit Logik 2Ch Off: Kontakt SCA Meldeleute Tor offen. Mit Logik 2ch On: Kontakt durch den Funkkanal 2 des Empfängers gesteuert. Bemerkung: Logik SRL auf On hat die Kontaktfunktion zur Steuerung der Höflichkeitsleuchte, siehe Tabelle Logik. 11-12 24 Vdc Ausgang Speisung Zubehör 24Vdc/0,5A max. (11:+, 12:-) 13 COM Gemein für Endschalter und alle Steuerungseingänge. 14 SWO1 Eingang Endschalter ÖFFNEN Motor 1 (Kontakt N.C.) 15 SWC1 Eingang Endschalter SCHLIESSEN Motor 1 (Kontakt N.C.) 16 SWO2 Eingang Endschalter ÖFFNEN Motor 2 (Kontakt N.C.) 17 SWC2 Eingang Endschalter SCHLIESSEN Motor 2 (Kontakt N.C.) 18 PHOT Eingang Fotozelle aktiv beim Öffnen und Schließen; 19 PHOT C Eingang Fotozelle aktiv nur beim Schließen 20 STOP Eingang Taste STOP (Kontakt N.C.) 21 OPEN Eingang Taste ÖFFNEN (Kontakt N.O.) 22 CLOSE Eingang Taste SCHLIESSEN (Kontakt N.O.) 23 PED Eingang Taste Fußgänger (Kontakt N.O.), steuert das vollständige Öffnen des Motors 1 24 Schritt-Schritt Eingang Taste Schritt-Schritt (Kontakt N.O.) 25 COM Gemein für alle Steuerungseingänge. 26-27 BAR Eingang Kontakt Näherungsflanke Widerstandsfähige Flanke: Jumper DAS geschlossen Mechanische Flanke: Jumper DAS geöffnet Das Einschalten der Flanke hält die Bewegung des Flügels an und schaltet ca. 3 sec. lang um. 30-31 Antenne Anschluss Antenne der Karte des steckbaren Funkempfängers (30-Signal/31-Schirm). JF1-JF2 24Vac/dc Eingang Speisung 24Vac/24Vdc von der Sekundärwicklung des Trafos. Bei Gebrauch von Pufferbatterien, die Karte CB.24V (Option) laut Schaltplan anschließen. Programmierung Die Programmierung der verschiedenen Funktionen der Steuerzentrale erfolgt über das LCD-Display an der Zentrale selbst, indem die gewünschten Werte in den nachstehend beschriebenen Programmierungs-Menüs eingegeben werden. Das Parameter-Menü ermöglicht die Eingabe eines numerischen Werts mit einer Funktion, analog wie ein Regeltrimmer. Das Logik-Menü ermöglicht das Aktivieren oder Deaktivieren einer Funktion, analog zum Einstellen eines Dip-Switch. Andere Sonderfunktionen folgen dem Parameter- und Logik-Menü und können ja nach Typ der Steuerzentrale oder der Software-Version variieren. 15

Für den Zugriff auf die Programmierung: 1 Die Taste <PG> drücken, das Display stellt sich auf das erste Parameter-Menü PAR. 2 Mit der Taste <+> oder <-> das gewünschte Menü selektieren. (PAR>>LOG>>RADIO>>NMAN>>RES>>PAR>>...). 3- Die Taste <PG> drücken, am Display wird die erste Funktion des Menüs sichtbar. 4 Mit der Taste <+> oder <-> die gewünschte Funktion selektieren. 5 - Die Taste <PG> drücken, am Display wird der derzeitig für die selektierte Funktion eingestellte Wert sichtbar. 6 Mit der Taste <+> oder <-> den für die Funktion gewünschten Wert selektieren. 7 - Die Taste <PG> drücken, am Display wird das Signal PRG sichtbar, welches die erfolgte Programmierung anzeigt. Anmerkungen: Durch gleichzeitiges Drücken von <+> und <->, innerhalb eines Funktionen-Menüs, wird zum vorherigen Menü zurückgekehrt, ohne Änderungen durchzuführen. Durch gleichzeitiges Drücken von <+> und <->, bei ausgeschaltetem Display, wird die Software-Version der Platine angezeigt. Durch gedrückt halten der Taste <+> oder der Taste <-> wird das zunehmende oder abnehmende Ablaufen der Werte beschleunigt. Nach einer Wartezeit von 60s verlässt die Steuerzentrale den Programmiermodus und das Display schaltet sich aus. Parameter, Logiken und Sonderfunktionen In den folgenden Tabellen werden die einzelnen Funktionen der Steuerzentrale beschrieben. MENÜ FUNKTION Einstellbare Werte MIN-MAX-(Default) MEMO TCA Automatikverschlusszeit. Aktiv nur mit Logik TCA =ON. Nach Ablauf der eingegebenen Zeit steuert die Steuerzentrale ein Verschlussmanöver. 1-240-(40s) TM1 Anschluss an den Motor 1. Regelt die Betriebszeit mit normaler Geschwindigkeit während des Öffnens und Schließens des Motors 1. Siehe Paragraph Regelung der Geschwindigkeitsabnahme. 5-180-(24s) TM2 Anschluss an den Motor 2. Regelt die Betriebszeit mit normaler Geschwindigkeit während des Öffnens und Schließens des Motors 2. Siehe Paragraph Regelung der Geschwindigkeitsabnahme. 5-180-(24s) PMo1 Regelt das für den Motor 1 angelegte Drehmoment beim Öffnen. * 1-99-(50%) PMC1 Regelt das für den Motor 1 angelegte Drehmoment beim Schließen.* 1-99-(50%) PARAMETER PMo2 Regelt das für den Motor 2 angelegte Drehmoment beim Öffnen. 1-99-(50%) PMc2 Regelt das für den Motor 2 angelegte Drehmoment beim Schließen.* 1-99-(50%) TDMo TDMC TLOc Verzögerungszeit Öffnen Mot.2 Regelt die Verzögerungszeit beim Öffnen des Motors 2 im Vergleich zum Motor 1 Verzögerungszeit Schließen Mot.1 Regelt die Verzögerungszeit beim Schließen des Motors 1 im Vergleich zum Motor 2 Aktivierungszeit Elektroverriegelung. Wird die Elektroverriegelung nicht verwendet, den Parameter auf 0 stellen. 0-15-(2s) 0-40-(3s) 0-5-(3s) SLDS Pso1 Psc1 Pso2 Psc2 Regelt die Geschwindigkeit des Motors während der Phase der Geschwindigkeitsabnahme. Der Wert wird in Prozent im Verhältnis zur normalen Betriebsgeschwindigkeit ausgedrückt. Regelt das für den Motor 1 angelegte Drehmoment während der Geschwindigkeitsabnahme beim Schließen.* Regelt das für den Motor 1 angelegte Drehmoment während der Geschwindigkeitsabnahme beim Öffnen.* Regelt das für den Motor 2 angelegte Drehmoment während der Geschwindigkeitsabnahme beim Schließen.* Regelt das für den Motor 2 angelegte Drehmoment während der Geschwindigkeitsabnahme beim Öffnen.* 30-99-(30) 1-99-(50%) 1-99-(50%) 1-99-(50%) 1-99-(50%) * ACHTUNG: Eine falsche Einstellung dieser Parameter kann gefährlich sein. Die geltenden Vorschriften beachten! Regelung der Geschwindigkeitsabnahme. Bei freigegebener Geschwindigkeitsabnahme (Logik SLD: ON) beginnt diese wenn die durch TM1 und TM2 eingestellte Zeit abgelaufen ist. Die eingestellte Zeit muss daher kürzer als der tatsächliche Hub der Automatik sein. Bsp.: bei einem Hub von 20 sec., 17 sec. 16

einstellen um die Geschwindigkeitsabnahme 3 sec. vor beendeter Steuerung einzuschalten. Bemerkung: Die Parameter TM1 und TM2 haben keinen Einfluss wenn die Geschwindigkeitsabnahme deaktiviert ist (Logik SLD: OFF), weil das Ende der Steuerung ausschließlich durch das Einschalten des Endschalters oder des Stromsensors bestimmt wird. Die Geschwindigkeit des Motors während der Phase der Geschwindigkeitsabnahme wird durch den Wert des Parameters SLDS bestimmt. MENÜ FUNKTION Einstellbare Werte ON-OFF-(Default) MEMO TCA Aktiviert oder deaktiviert das automatische Schließen Off: Automatisches Schließen deaktiviert On: Automatisches Schließen aktiviert (ON) IbL Aktiviert oder deaktiviert die Mehrbenutzerfunktion. Off: Mehrbenutzerfunktion aktiviert. On: Mehrbenutzerfunktion deaktiviert. Der Impuls Schrittschaltung oder des Senders hat während des Öffnens keine Auswirkung. SCL Aktiviert oder deaktiviert das schnelle Schließen On: Schnelles Schließen aktiviert. Bei offenem Tor oder während des Öffnens verursacht das Auslösen der Photozelle nach 3 s ein automatisches Schließen. Aktiv nur bei TCA:ON Off: Schnelles Schließen deaktiviert Sld Aktiviert oder deaktiviert die Verlangsamung. Off: Verlangsamung ausgeschlossen. On: Verlangsamung aktiv. PP Selektiert den Funktionsmodus Taste Schrittschaltung und des Senders. Off: Funktion: ÖFFNEN > STOPP > SCHLIESSEN > STOPP > On: Funktion: ÖFFNEN > SCHLIESSEN > ÖFFNEN > LOGIKEN PRE Blc Aktiviert oder deaktiviert das Vorwarnblinken. Off: Vorwarnblinken deaktiviert. On: Vorwarnblinken aktiviert. Die Blinkleuchte schaltet sich 3s vor Anlaufen des Motors ein. Aktiviert oder deaktiviert die Funktion Verriegelung. Off: Funktion Verriegelung deaktiviert. On: Funktion Verriegelung aktiviert. Nach dem Einschalten der Endschalter der Schließfunktion, verzögert die Zentrale das Anhalten um circa 0,5 sec., um einen einwandfreien Anschlag des Flügels gegen die Endanschläge zu gewährleisten. (ON) CLOC Selektiert den Modus des Eingangs ÖFFNEN Off: Eingang ÖFFNEN mit Funktion ÖFFNEN On: Eingang ÖFFNEN mit Funktion UHR. Zu verwenden bei Anschluss mit Timer für zeitgeregeltes Öffnen/ Schließen. (Kontakt GESCHLOSSEN - Tor geöffnet, Kontakt offen, normale Funktion). htr Aktiviert oder deaktiviert den Bedienbetrieb. Off: Automatikbetrieb. On: Bedienbetrieb. Die Tasten ÖFFNEN/SCHLIESSEN müssen während des gesamten Manövers gedrückt gehalten werden. mloc Selektiert den Typ der verwendeten Elektroverriegelung. Off: Elektroverriegelung mit Auslösung, normalerweise nicht gespeist. Vor jedem Manöver zum Öffnen wird für die mit dem Parameter TLOC eingestellte Zeit eine 12Vac Speisung geliefert. On: Magnetische Elektroverriegelung, normalerweise mit 12Vac gespeist. Vor jedem Manöver zum Öffnen wird für die mit dem Parameter TLOC eingestellte Zeit die Speisung unterbrochen. 1mot Wählt die Betriebsweise des Ausgangs 1-2 Motoren: Off: Beide Motoren aktiv. On: Nur 1 Motor aktiv. 17

MENÜ FUNKTION Einstellbare Werte ON-OFF-(Default) MEMO Cvar Aktiviert oder deaktiviert die Sendegeräte mit programmierbarem Code. On: Funkempfänger ist nur für Sendegeräte mit variablem Code aktiviert (Rolling-Code). Off: Funkempfänger ist für Sendegeräte mit variablem Code (Rolling-Code) und programmierbare (Selbstlernfunktion und Dip-Schalter) Sendegeräte aktiviert. LOGIKEN NOlS 2Ch Wählt die Betriebsweise des Stromsensors in Gegenwart oder Abwesenheit der Endschalter. Off: Endschalter vorhanden. Das Einschalten des Stromsensors wird von der Zentrale als Gegenwart eines Hindernisses auf dem Weg des Flügels interpretiert. Daher wird die Bewegung durch die Steuerung gestoppt und circa 3 sec. umgekehrt, wie es beim Einschalten der Flanke der Fall ist. On: Endschalter nicht vorhanden. Das Einschalten des Stromsensors wird von der Zentrale als Endschalter interpretiert. Daher wird die Bewegung durch die Steuerung gestoppt. Bemerkung: Die Kontakte der Endschalter mit Brücken schließen, falls diese Funktion verwendet werden soll. Wählt die Betriebsweise des Ausgangs an den Klemmen 9-10: On: Der Ausgang hat die Funktion 2. Funkkanal: der Kontakt ein Arbeitskontakt schaltet 1 sec. lang auf den Empfang einer Funksteuerung um, die dem 2. Funkkanal zugeteilt ist. Siehe Menü Funk. Off: Der Ausgang hat die Funktion SCA, Meldeleuchte Tor offen: offener Kontakt bei geschlossenem Flügel, aussetzend während der Flügelbewegung, bei offenem Flügel geschlossener Kontakt. Siehe Schaltplan. serl Aktiviert oder deaktiviert die Funktion Dienstlicht am Ausgang 9-10. On: bei jeder Schaltung wird der Kontakt circa 90 sec. lang geschlossen, unabhängig von der Konfiguration des Parameters 2ch. Ein Hilfsrelais für die Lichtsteuerung verwenden. Off: Das Verhalten des Ausgangs wird durch den Parameter 2ch bestimmt, siehe vorhergehenden Parameter. MENÜ FUNKTION PP Wird diese Funktion gewählt, wartet (Push) der Empfänger auf einen Sendercode der der Schritt-Schritt-Funktion zugeteilt werden muss. Taste des Sendegeräts drücken, dem diese Funktion zugeteilt werden soll. Ist der Code gültig, wird dieser gespeichert und die Meldung OK angezeigt. Ist der Code ungültig, wird die Meldung Err angezeigt. FUNK 2ch Wird diese Funktion gewählt, wartet (Push) der Empfänger auf einen Sendercode der dem zweiten Funkkanal, an den Klemmen 9-10 zugeteilt werden muss. Die Logik 2ch muss auf ON, die Logik SERL muss auf OFF geschaltet sein. Taste des Sendegeräts drücken, dem diese Funktion zugeteilt werden soll. Ist der Code gültig, wird dieser gespeichert und die Meldung OK angezeigt. Ist der Code ungültig, wird die Meldung Err angezeigt. CLr RTR MENÜ NMAN Wird diese Funktion gewählt, wartet (Push) der Empfänger auf einen Sendercode der gelöscht werden muss. Ist der Code gültig, wird dieser gelöscht und die Meldung OK angezeigt. Ist der Code ungültig oder nicht gespeichert, wird die Meldung Err angezeigt. Löscht den gesamten Speicher des Empfängers. Der Vorgang muss bestätigt werden. FUNKTION Zeigt die Zahl der von der Automatisierung ausgeführten kompletten Zyklen (Öffnen+Schließen) an. Beim erstmaligen Drücken der Taste <PG> erscheinen die ersten 4 Ziffern, beim zweiten Drücken die letzten 4. Beispiel <PG> 0012 >>> <PG> 3456: es wurden 123.456 Zyklen ausgeführt. 18 RES RESET der Steuerzentrale. ACHTUNG!: Bringt die Zentrale auf die Default-Werte zurück. Beim erstmaligen Drücken der Taste <PG> blinkt die Schrift RES, beim weiteren Drücken der Taste <PG> erfolgt das Reset der Steuerzentrale. Bemerkung: Die Sendegeräte werden nicht aus dem Empfänger gelöscht. Programmierbeispiel Wir nehmen an, es soll: - Eine automatische Zeit für Schließen (TCA) von 100s eingegeben werden - Das Vorwarnblinken aktiviert werden dazu Schritt für Schritt die nachstehend beschriebenen Operationen durchführen:

Schritt Drücken Display Anmerkung 1 PAR Erstes Menü 2 TCA Erste Funktion des ersten Menüs 3 040 Derzeit für die selektierte Funktion eingestellter Wert 4 100 Mit den Tasten <+> und <-> den gewünschten Wert eingeben 5 PRG Der Wert wird programmiert TCA Nach erfolgter Programmierung stellt sich das Display auf die soeben eingestellte Funktion zurück 6 PAR Gleichzeitig <+> und <-> drücken, um zum höheren Menü zu gehen 7 Log Zweites Menü 8 TCA Erste Funktion des zweiten Menüs 9 Pre Solange <-> drücken, bis die Logik PRE selektiert ist 10 OFF Derzeit für die selektierte Funktion eingestellter Wert 11 ON Mit den Tasten <+> und <-> den gewünschten Wert eingeben 12 PRG Der Wert wird programmiert Pre Nach erfolgter Programmierung stellt sich das Display auf die soeben eingestellte Funktion zurück 13 PAR Gleichzeitig <+> und <-> drücken, um zum höheren Menü zurückzugehen und die Programmierung zu verlassen, oder 30s abwarten. Diagnose Bei Betriebsstörungen kann man durch Drücken der Taste + oder -, den Zustand aller Eingänge anzeigen lassen (Endschalter, Steuerung und Sicherheit). Jedem Eingang ist ein Displaysegment zugeteilt, das bei der Aktivierung laut nachstehendem Schema aufleuchtet Den normalerweise geschlossenen Eingängen entsprechen die vertikalen Segmente. Den normalerweise offenen Eingänge entsprechen die horizontalen Segmente. Das Display sieht beispielsweise so aus, bei vollständig geschlossenen Torflügeln: Wenn ein Impuls Open gegeben wird: Während des Öffnens: Bei vollständig geöffneten Torflügeln : 19

Logique de commande BRAIN 24 La logique de commande électronique BRAIN 24 peut être utilisée pour le contrôle d 1 ou de 2 moteurs 24Vdc s une puissance ne dépassant pas 80W + 80W. RECOMMANDATIONS GÉNÉRALES a) L installation électrique et la logique de fonctionnement doivent être conformes aux normes en vigueur. b) Les conducteurs alimentés à des tensions différentes doivent être séparés physiquement ou bien, ils doivent être isolés de manière appropriée avec une gaine supplémentaire d au moins 1 mm. c) Les conducteurs doivent être assurés par une fixation supplémentaire à proximité des bornes. d) Recontrôler toutes les connexions faites avant d alimenter la logique de commande. e) Les entrées N.F. non utilisées doivent être shuntées. N Bornes Fonction Description FONCTIONS ENTRÉES/SORTIES Logique de commande BRAIN 24 1-2 Moteur 1 Branchement Moteur 1: 24Vdc 80W max 3-4 Moteur 2 Branchement Moteur 2: 24Vdc 80W max 5-6 Clignotant Branchement Clignotant 24Vdc 15W max. 7-8 Lock Sortie alimentation 12Vac/10W pour serrure électrique (7:0V, 8:+12V) 9-10 SCA/2 Ch radio Contact propre N.O. Contrôlé par la logique 2Ch. Avec logique 2ch Off: Contact SCA lampe témoin portail ouvert. Avec logique 2ch On: Contact contrôlé par le canal 2 du récepteur radio. Note: voir tableau logique SRL :On, joue la fonction de contact pour commande de lumière de courtoisie, voir tableau logiques. 11-12 24 Vdc Sortie alimentation accessoires 24Vdc/0,5A max. (11:+, 12:-) 13 COM Commun pour fin de corse et toutes les entrées de commande. 14 SWO1 Entrée fin de course OUVRE Moteur 1 (contact N.C.) 15 SWC1 Entrée fin de course FERME Moteur 1 (contact N.C.) 16 SWO2 Entrée fin de course OUVRE Moteur 2 (contact N.C.) 17 SWC2 Entrée fin de course FERME Moteur 2 (contact N.C.) 18 PHOT Entrée photocellule active soit en phase d ouverture que de fermeture 19 PHOT C Entrée photocellule active uniquement en phase de fermeture 20 STOP Entrée touche STOP (contact N.C.) 21 OPEN Entrée touche OUVRE (contact N.O.). 22 CLOSE Entrée touche FERME (contact N.O.) 23 PED Entrée touche piétonne (contact N.O.), commande l ouverture totale du Moteur 1 24 Pas à pas Entrée touche pas à pas (contact N.O.) 25 COM Commun pour toutes les entrées de commande. 26-27 BAR Entrée contact barre à palpeurs Barre résistive: Jumper DAS fermé Barre mécanique: Jumper DAS ouvert L intervention de la barre arrête le mouvement du vantail et invertit pour 3sec. environ. 30-31 Antenne Branchement antenne fiche récepteur radio embrochable (30-signal/31-écran). JF1-JF2 24Vac/dc Entrée alimentation 24Vac/24Vdc du secondaire du transformateur. En cas d utilisation de batteries de secours brancher la fiche CB.24V (optionnel) comme l indique le schéma. Programmation La programmation des différentes fonctions de la logique de commande est effectuée en utilisant l afficheur à cristaux liquides présent sur le tableau de la logique et en programmant les valeurs désirées dans les menus de programmation décrits ci-après. Le menu paramètres permet d associer une valeur numérique à une fonction, comme pour un trimmer de réglage. Le menu des logiques permet d activer ou de désactiver une fonction, comme pour le réglage d un dip-switch. D autres fonctions spéciales suivent les menus paramètres et logiques et peuvent varier suivant le type de logique de commande ou de version de logiciel. 20

Pour accéder à la programmation : 1 - Presser la touche <PG>, l afficheur présente le premier menu Paramètres PAR. 2 - Choisir avec la touche <+> ou <-> le menu que l on souhaite sélectionner (PAR>>LOG>>RADIO>>NMAN>>RES>>PAR>>...). 3 - Presser la touche <PG>, l afficheur présente la première fonction disponible dans le menu. 4 - Choisir avec la touche <+> ou <-> la fonction que l on souhaite sélectionner. 5 - Presser la touche <PG>, l afficheur montre la valeur actuellement programmée pour la fonction sélectionnée. 6 - Choisir avec la touche <+> ou <-> la valeur que l on souhaite attribuer à la fonction. 7 - Presser la touche <PG>, l afficheur montre le signal PRG qui indique que la programmation a eu lieu. Notes : La pression simultanée de <+> et <-> effectuée à l intérieur d un menu fonction permet de revenir au menu supérieur sans apporter de modification. La pression simultanée de <+> et <-> effectuée avec l afficheur éteint affiche la version logicielle de la carte. Maintenir la pression sur la touche <+> ou sur la touche <-> pour accélérer l incrémentation/décrémentation des valeurs. Après une attente de 60 s, la logique de commande sort du mode programmation et éteint l afficheur. Paramètres, Logiques et Fonctions spéciales Les tableaux ci de suit décrivent singulièrement les fonctions disponibles dans la centrale. MENU FONCTION Valeurs programmables MIN-MAX-(Default) MÉMO TCA Temps de fermeture automatique. Actif seulement avec logique TCA =ON. À la fin du temps programmé, la logique commande une manœuvre de fermeture. 1-240-(40s) TM1 Temps travail Moteur 1. Règle le temps de fonctionnement à vitesse normale durant la phase d ouverture et fermeture du Moteur 1. Voir paragraphe Réglage ralentissement. 5-180-(24s) TM2 Temps travail Moteur 2. Règle le temps de fonctionnement à vitesse normale durant la phase d ouverture et fermeture du Moteur 2. Voir paragraphe Réglage ralentissement. 5-180-(24s) PMo1 Règle le couple appliqué au Moteur 1 durant la phase d ouverture. * 1-99-(50%) PMC1 Règle le couple appliqué al Moteur 1 durant la phase de fermeture.* 1-99-(50%) PARAMETRES PMo2 Règle le couple appliqué al Moteur 2 durant la phase d ouverture.* 1-99-(50%) PMc2 Règle le couple appliqué al Moteur 2 durant la phase de fermeture.* 1-99-(50%) TDMo TDMC TLOc Temps de retard ouverture Mot. 2. Règle le temps de retard en ouverture du moteur 2 par rapport au moteur 1 Temps de retard fermeture Mot. 1. Règle le temps de retard en fermeture du moteur 1 par rapport au moteur 2 Temps d activation serrure électrique. Si on n utilise pas de serrure électrique, programmer la valeur 0 pour ce paramètre. 0-15-(2s) 0-40-(3s) 0-5-(3s) SLDS Pso1 Psc1 Pso2 Psc2 Règle la vitesse du Moteur durant les phases de ralentissement. Valeur exprimée en pourcentage vis-à-vis de la vitesse normale de fonctionnement. Règle le couple appliqué au Moteur 1 durant le ralentissement en phase de fermeture* Règle le couple appliqué au Moteur 1 durant le ralentissement en phase d ouverture* Règle le couple appliqué au Moteur 2 durant le ralentissement en phase de fermeture * Règle le couple appliqué au Moteur 2 durant le ralentissement en phase d ouverture * 30-99-(30) 1-99-(50%) 1-99-(50%) 1-99-(50%) 1-99-(50%) * ATTENTION: Un réglage erroné de ces paramètres peut s avérer dangereux. Respectez les normes en vigueur! Réglage ralentissement Avec ralentissement habilité (logique SLD:ON), à la fin du temps réglé avec TM1 et TM2, la phase de ralentissement commence. Donc le temps réglé doit être inférieur à la course effective de l automatisme. Par ex. avec une course de 20sec, affichez 17sec pour commencer la phase de ralentissement avec 3 sec d avance par rapport à la fin de la manœuvre. Note: Les paramètres TM1 et TM2 sont ininfluents avec le ralentissement hors service (logique SLD:OFF), étant donné que la fin 21