Możliwości wykorzystania strumienia unipolarnego w diagnostyce maszyn prądu przemiennego



Podobne dokumenty
DIAGNOZOWANIE SILNIKÓW INDUKCYJNYCH W OPARCIU O POMIAR STRUMIENIA OSIOWEGO

METODA WSTĘPNEJ OCENY STANU WIRNIKA SILNIKA INDUKCYJNEGO PRZY POMOCY DEDYKOWANEGO PRZYRZĄDU OPARTEGO NA POMIARZE STRUMIENIA POOSIOWEGO

Maszyny Elektryczne - Zeszyty Problemowe Nr 2/2016 (110) 155

BADANIA SKUTKÓW CIEPLNYCH ZWARĆ ZWOJOWYCH W UZWOJENIACH STOJANA SILNIKA INDUKCYJNEGO

CHARAKTERYSTYKI EKSPLOATACYJNE SILNIKA INDUKCYJNEGO Z USZKODZONĄ KLATKĄ WIRNIKA

DIAGNOSTYKA SILNIKA INDUKCYJNEGO Z ZASTOSOWANIEM SYGNAŁU SKUTECZNEJ WARTOŚCI RUCHOMEJ PRĄDU CZĘŚĆ 2 ZASILANIE NIESYMETRYCZNE

ZASTOSOWANIE SYGNAŁU SKUTECZNEJ WARTOŚCI RUCHOMEJ PRĄDU STOJANA W DIAGNOSTYCE SILNIKA INDUKCYJNEGO PODCZAS ROZRUCHU

WYKRYWANIE ZWARĆ ZWOJOWYCH W MASZYNACH ELEKTRYCZNYCH NA STACJI PRÓB Z WYKORZYSTANIEM CEWKI DO POMIARU STRUMIENIA POOSIOWEGO

Diagnostyka silnika indukcyjnego z wykorzystaniem dostępnych napięć stojana

BADANIA USZKODZEŃ UZWOJENIA STOJANA KLATKOWEGO SILNIKA INDUKCYJNEGO

ZASTOSOWANIE STRUMIENIA POOSIOWEGO DO OCENY STANU TECHNICZNEGO SILNIKA KLATKOWEGO W TRAKCIE ROZRUCHU. CZĘŚĆ I: NIESYMETRIA WIRNIKA

ZASTOSOWANIE RUCHOMEJ WARTOŚCI SKUTECZNEJ PRĄDU DO DIAGNOSTYKI SILNIKÓW INDUKCYJNYCH KLATKOWYCH

ZWARCIA ZWOJOWE W UZWOJENIU STOJANA KLATKOWEGO SILNIKA INDUKCYJNEGO

SILNIK INDUKCYJNY KLATKOWY

Diagnostyka silników indukcyjnch dwuklatkowych z uszkodzonymi prętami

Ćwiczenie: "Silnik indukcyjny"

OBLICZENIOWE BADANIE ZJAWISK WYWOŁANYCH USZKODZENIEM KLATKI WIRNIKA

BADANIA EKSPERYMENTALNE SILNIKA INDUKCYJNEGO Z USZKODZONĄ KLATKĄ WIRNIKA

ZWARCIE POMIAROWE JAKO METODA WYKRYWANIA USZKODZEŃ KLATKI WIRNIKA SILNIKA INDUKCYJNEGO

ZWARTE PRĘTY ROZRUCHOWE W SILNIKU SYNCHRONICZNYM Z MAGNESAMI TRWAŁYMI O ROZRUCHU BEZPOŚREDNIM

CHARAKTERYSTYKI EKSPLOATACYJNE SILNIKA INDUKCYJNEGO DUŻEJ MOCY Z USZKODZONĄ KLATKĄ WIRNIKA

Rozwój sterowania prędkością silnika indukcyjnego trójfazowego

DIAGNOSTYKA SILNIKA INDUKCYJNEGO Z WYKORZYSTANIEM DOSTĘPNYCH NAPIĘĆ STOJANA

WYKRYWANIE USZKODZEŃ UZWOJENIA STOJANA W SILNIKU INDUKCYJNYM KLATKOWYM Z GAŁĘZIAMI RÓWNOLEGŁYMI

Wyznaczanie strat w uzwojeniu bezrdzeniowych maszyn elektrycznych

SYSTEM POMIAROWO-DIAGNOSTYCZNY DO BEZINWAZYJNEJ DIAGNOSTYKI STANU WIRNIKA SILNIKÓW INDUKCYJNYCH

SILNIK INDUKCYJNY KLATKOWY

Alternator. Elektrotechnika w środkach transportu 125

MODEL POLOWO-OBWODOWY SILNIKA INDUKCYJNEGO ZE ZWARCIAMI ZWOJOWYMI

SILNIK SYNCHRONICZNY ŚREDNIEJ MOCY Z MAGNESAMI TRWAŁYMI ZASILANY Z FALOWNIKA

WYZNACZANIE MOMENTU OBCIĄŻENIA SILNIKA INDUKCYJNEGO W OPARCIU O POMIAR STRUMIENIA POOSIOWEGO

PRĄDNICE I SILNIKI. Publikacja współfinansowana ze środków Unii Europejskiej w ramach Europejskiego Funduszu Społecznego

ZJAWISKA W OBWODACH TŁUMIĄCYCH PODCZAS ZAKŁÓCEŃ PRACY TURBOGENERATORA

ZASTOSOWANIE SKOSU STOJANA W JEDNOFAZOWYM SILNIKU SYNCHRONICZNYM Z MAGNESAMI TRWAŁYMI

WPŁYW EKSCENTRYCZNOŚCI STATYCZNEJ WIRNIKA I NIEJEDNAKOWEGO NAMAGNESOWANIA MAGNESÓW NA POSTAĆ DEFORMACJI STOJANA W SILNIKU BLDC

WPŁYW USZKODZENIA TRANZYSTORA IGBT PRZEKSZTAŁTNIKA CZĘSTOTLIWOŚCI NA PRACĘ NAPĘDU INDUKCYJNEGO

MASZYNY INDUKCYJNE SPECJALNE

System pomiarowo-diagnostyczny do bezinwazyjnej diagnostyki stanu wirnika i wyznaczania parametrów pracy silników indukcyjnych

Detekcja asymetrii szczeliny powietrznej w generatorze ze wzbudzeniem od magnesów trwałych, bazująca na analizie częstotliwościowej prądu

BADANIA PORÓWNAWCZE SILNIKA INDUKCYJNEGO KLATKOWEGO PODCZAS RÓŻNYCH SPOSOBÓW ROZRUCHU 1. WSTĘP

DIAGNOSTYKA SILNIKA INDUKCYJNEGO KLATKOWEGO WYKRYWANIE NIECENTRYCZNOŚCI

Temat: ŹRÓDŁA ENERGII ELEKTRYCZNEJ PRĄDU PRZEMIENNEGO

Pracownia Automatyki i Elektrotechniki Katedry Tworzyw Drzewnych Ćwiczenie 5. Analiza pracy oraz zasada działania silników asynchronicznych

WPŁYW ROZMIESZCZENIA MAGNESÓW NA WŁAŚCIWOŚCI EKSPOATACYJNE SILNIKA TYPU LSPMSM

Badanie skuteczności ochrony łożysk przed skutkami przepływu prądów łożyskowych z zastosowaniem pierścieni zwierających

DIAGNOSTYKA SILNIKÓW INDUKCYJNCH DWUKLATKOWYCH Z USZKODZONYMI PRĘTAMI

DEFEKTY WIRNIKÓW SILNIKÓW INDUKCYJNYCH DUŻYCH MOCY, TERMOGRAFICZNA OCENA STANU TECHNICZNEGO

LABORATORIUM PRZETWORNIKÓW ELEKTROMECHANICZNYCH

Badanie silnika indukcyjnego jednofazowego i transformatora

Silnik indukcyjny - historia

ZAGADNIENIA STANÓW DYNAMICZNYCH TRÓJFAZOWYCH SILNIKÓW INDUKCYJNYCH W WYBRANYCH NIESYMETRYCZNYCH UKŁADACH POŁĄCZEŃ

POLOWO-OBWODOWY MODEL DWUBIEGOWEGO SILNIKA INDUKCYJNEGO

GĘSTOŚĆ PRĄDU W PRĘTACH USZKODZONEJ KLATKI WIRNIKA SILNIKA INDUKCYJNEGO

Termograficzna ocena stanu technicznego wirników silników indukcyjnych

Maszyny elektryczne. Materiały dydaktyczne dla kierunku Technik Optyk (W12) Kwalifikacyjnego kursu zawodowego.

BADANIE SKUTECZNOŚCI OCHRONY ŁOŻYSK PRZED SKUTKAMI PRZEPŁYWU PRĄDÓW ŁOŻYSKOWYCH Z ZASTOSOWANIEM PIERŚCIENI ZWIERAJĄCYCH

BADANIE SKUTECZNOŚCI OCHRONY ŁOŻYSK PRZED SKUTKAMI PRZEPŁYWU PRĄDÓW ŁOŻYSKOWYCH Z ZASTOSOWANIEM PIERŚCIENI ZWIERAJĄCYCH

Silniki prądu przemiennego

Maszyny elektryczne. Materiały dydaktyczne dla kierunku Technik Optyk (W10) Szkoły Policealnej Zawodowej.

ROZRUCH SILNIKÓW SYNCHRONICZNYCH DUŻEJ MOCY PRZY CZĘŚCIOWYM ZASILANIU UZWOJENIA STOJANA

OKREŚLENIE WPŁYWU WYŁĄCZANIA CYLINDRÓW SILNIKA ZI NA ZMIANY SYGNAŁU WIBROAKUSTYCZNEGO SILNIKA

Silniki indukcyjne. Ze względu na budowę wirnika maszyny indukcyjne dzieli się na: -Maszyny indukcyjne pierścieniowe. -Maszyny indukcyjne klatkowe.

MOMENT ORAZ SIŁY POCHODZENIA ELEKTROMAGNETYCZNEGO W DWUBIEGOWYM SILNIKU SYNCHRONICZNYM

WIELOETAPOWY PROCES DIAGNOSTYKI UKŁADÓW NAPĘDOWYCH

WYKRYWANIE USZKODZEŃ W LITYCH ELEMENTACH ŁĄCZĄCYCH WAŁY

UKŁADY NAPĘDOWE Z SILNIKAMI INDUKCYJNYMI STEROWANE METODAMI WEKTOROWYMI DFOC ORAZ DTC-SVM ODPORNE NA USZKODZENIA PRZEMIENNIKA CZĘSTOTLIWOŚCI

PORÓWNANIE SILNIKA INDUKCYJNEGO ORAZ SYNCHRONICZNEGO Z MAGNESAMI TRWAŁYMI I ROZRUCHEM BEZPOŚREDNIM - BADANIA EKSPERYMENTALNE

WPŁYW KSZTAŁTU SZCZELINY POWIETRZNEJ NA WŁAŚCIWOŚCI SILNIKA SYNCHRONICZNEGO WZBUDZANEGO MAGNESAMI TRWAŁYMI

WŁAŚCIWOŚCI EKSPLOATACYJNE SILNIKÓW RELUKTANCYJNYCH Z ROZRUCHEM ASYNCHRONICZNYM PRZY STEROWANIU CZĘSTOTLIWOŚCIOWYM

POLOWO OBWODOWY MODEL DWUBIEGOWEGO SILNIKA SYNCHRONICZNEGO WERYFIKACJA POMIAROWA

ANALIZA WPŁYWU NIESYMETRII NAPIĘCIA SIECI NA OBCIĄŻALNOŚĆ TRÓJFAZOWYCH SILNIKÓW INDUKCYJNYCH

Diagnostyka uszkodzeń elektrycznych silnika indukcyjnego zasilanego z przemiennika częstotliwości w zamkniętej strukturze sterowania

Sposób analizy zjawisk i właściwości ruchowych maszyn synchronicznych zależą od dwóch czynników:

FALKOWA ANALIZA STRUMIENIA OSIOWEGO SILNIKA INDUKCYJNEGO PRACUJĄCEGO NA BIEGU JAŁOWYM

Diagnostyka ukladów napedowych

ANALIZA PRACY SILNIKA SYNCHRONICZNEGO Z MAGNESAMI TRWAŁYMI W WARUNKACH ZAPADU NAPIĘCIA

!!!!!!!!!! WNIOSEK O PORTFOLIO: Automatyczna bezinwazyjna diagnostyka symetrii wirnika maszyn indukcyjnych. Autorzy: dr inż.

PROBLEMY PRAKTYCZNEJ DIAGNOSTYKI MASZYN INDUKCYJNYCH W PRZEMYŚLE

Badanie prądnicy synchronicznej

BADANIA GENERATORA INDUKCYJNEGO WZBUDZANEGO KONDENSATORAMI OBCIĄŻENIE NIESYMETRYCZNE

WSPÓŁCZYNNIK MOCY I SPRAWNOŚĆ INDUKCYJNYCH SILNIKÓW JEDNOFAZOWYCH W WARUNKACH PRACY OPTYMALNEJ

PRACA RÓWNOLEGŁA PRĄDNIC SYNCHRONICZNYCH WZBUDZANYCH MAGNESAMI TRWAŁYMI

DROGI PRZEPŁYWU PRĄDÓW ŁOŻYSKOWYCH W UKŁADACH NAPĘDOWYCH DUŻEJ MOCY ZASILANYCH NAPIĘCIEM SIECIOWYM

Silniki prądu stałego z komutacją bezstykową (elektroniczną)

15. UKŁADY POŁĄCZEŃ PRZEKŁADNIKÓW PRĄDOWYCH I NAPIĘCIOWYCH

Maszyna indukcyjna jest prądnicą, jeżeli prędkość wirnika jest większa od prędkości synchronicznej, czyli n > n 1 (s < 0).

Napięcia wałowe i prądy łożyskowe w silnikach indukcyjnych

Diagnozowanie i weryfikacja termowizyjna silników indukcyjnych z asymetrią elektromagnetyczną

DETEKCJA I LOKALIZACJA ZWARĆ ZWOJOWYCH SILNIKA INDUKCYJNEGO ZASILANEGO Z PRZEKSZTAŁTNIKA CZĘSTOTLIWOŚCI

STANY AWARYJNE MASZYNY RELUKTANCYJNEJ PRZEŁĄCZALNEJ W ZAKRESIE PRACY GENERATOROWEJ

ANALIZA WPŁYWU USZKODZENIA UZWOJENIA STOJANA SILNIKA INDUKCYJNEGO NA KĄT PRZESUNIĘCIA FAZOWEGO POMIĘDZY PRĄDEM I NAPIĘCIEM

METODA DIAGNOSTYKI USZKODZEŃ ELEKTRYCZNYCH SILNIKA RELUKTANCYJNEGO PRZEŁĄCZALNEGO

ANALIZA WŁASNOŚCI SILNIKA INDUKCYJNEGO SYNCHRONIZOWANEGO (LSPMSM) METODĄ OBLICZEŃ POLOWYCH.

Opracował: mgr inż. Marcin Wieczorek

KOMPUTEROWY SYSTEM DO MONITOROWANIA STANU UZWO- JEŃ STOJANA SILNIKA INDUKCYJNEGO

Diagnostyka drganiowa trakcyjnych maszyn elektrycznych - przykład asymetrii geometrii promieniowej między stojanem a wirnikiem

DIAGNOSTYKA DRGANIOWA SILNIKA INDUKCYJNEGO KLATKOWEGO W WYBRANYCH STANACH PRZEJŚCIOWYCH

POLOWO - OBWODOWY MODEL BEZSZCZOTKOWEJ WZBUDNICY GENERATORA SYNCHRONICZNEGO

BADANIE WYŁĄCZNIKA RÓŻNICOWOPRĄDOWEGO

Nr programu : nauczyciel : Jan Żarów

Transkrypt:

Możliwości wykorzystania strumienia unipolarnego w diagnostyce maszyn prądu przemiennego Janusz Petryna, Maciej Sułowicz, Arkadiusz Duda, Krzysztof Guziec 1. Wstęp Dla potrzeb skutecznego i bezinwazyjnego diagnozowania stanu maszyn elektrycznych poszukuje się coraz bardziej dokładnych i wyrafinowanych metod. Jedną z metod skutecznego diagnozowania stanu maszyn indukcyjnych klatkowych jest metoda pomiaru i analizy strumienia unipolarnego, czyli poosiowego. Próby zastosowania strumienia poosiowego do wykrywania uszkodzeń maszyn indukcyjnych zostały podjęte przez wielu badaczy już dawno. W pracach [1, 2] przedstawiono również badania autorów w tym zakresie. Nieprzerwanie prowadzone są badania skuteczności tej metody [1 8]. Najczęściej metoda pomiaru strumienia poosiowego jest wykorzystywana do wykrywania zwarć zwojowych. Przy pomocy tej metody można również wykryć uszkodzenie klatki wirnika. Artykuł zawiera wyniki badań w ramach projektu wykorzystania cewki do pomiaru strumienia unipolarnego dla uzyskania sygnału diagnostycznego niosącego informacje o niesymetriach elektrycznych maszyny (zwarcia zwojowe, defekty klatki) i prędkości obrotowej wirnika. 2. Metoda analizy strumienia poosiowego W idealnej maszynie indukcyjnej strumień poosiowy nie powinien występować. W praktyce zarówno w obwodach stojana, jak i wirnika występują różnego rodzaju asymetrie, wynikające z niedokładności geometrycznych w rozmieszczeniu uzwojeń lub niejednorodności materiałów. Na skutek tego typu niedokładności w maszynie powstaje niewielki, ale zauważalny strumień poosiowy. Właśnie ten sygnał strumienia poosiowego może być wykorzystany w diagnozowaniu uszkodzeń zarówno stojana, jak i wirnika maszyny indukcyjnej. Zaburzenia wynikające ze zwarć zwojowych stojana mają swoje odzwierciedlenie w prądzie wirnika. Uzwojenie wirnika w tej metodzie analizy pełni rolę pewnego rodzaju cewki pomiarowej, bo właśnie za sprawą zmian w jego prądzie powstaje strumień poosiowy. Na rys. 1 przedstawiono rozpływ strumienia w silniku indukcyjnym z uwzględnieniem strumienia poosiowego zamykającego się wzdłuż wału silnika [3, 4, 8]. Zwarcia zwojowe powodują zmianę rozkładu harmonicznych przestrzennych indukcji w szczelinie powietrznej. W strumieniu poosiowym można wykryć harmoniczne czasowe, które występują z harmonicznymi przestrzennymi pola. W zwartych zwojach indukuje się napięcie, które jest powodem przepływu prądu ograniczanego jedynie impedancją Streszczenie: Artykuł zawiera wyniki badań w ramach projektu wykorzystania cewki do pomiaru strumienia unipolarnego dla uzyskania sygnału diagnostycznego niosącego informacje: o niesymetriach elektrycznych maszyny (zwarcia zwojowe, defekty klatki); o prędkości obrotowej wirnika. Zwarcia zwojowe mogą być wykrywane zarówno w czasie rozruchu (kiedy to ujawniają się najczęściej), jak i w stanie ustalonym. Wykrywanie defektów klatki w stanie ustalonym ma charakter badania porównawczego, które powinno być ponawiane co jakiś czas w celu monitorowania ewentualnego rozwoju uszkodzenia. Dla napędów standardowych, które są zasilane z sieci i pracują w układach otwartych, można poprzez pomiar napięcia odwzorowującego strumień unipolarny dokonywać w razie potrzeby pomiaru i rejestracji prędkości obrotowej, co przeważnie prawie nigdy nie jest zapewniane w warunkach przemysłowych, również dla potrzeb pomiaru stanów dynamicznych i zmienności obrotów. W pracy pokazano, że prosta w swej konstrukcji, tania cewka może być bardzo przydatnym narzędziem diagnostycznym. Diagnozowanie maszyn tą metodą stanowić może cenne uzupełnienie, jak również potwierdzenie wyników badań zrealizowanych przy użyciu innych środków. Słowa kluczowe: strumień unipolarny, zwarcia zwojowe, uszkodzenie klatki POSSIBILITIES OF THE UNIPOLAR FLUX APPLICATON IN A.C. MACHINES DIAGNOSING Abstract: The article contains the results of research within the project to use unipolar (axial) flux coil to obtain diagnostic signal carrying the information of: electrical asymmetries of machinery (inter-turn stator short-circuits, cage damages); rotational speed of the rotor. Inter-turn stator short-circuits can be detected both at starting process time (when they appear most often), as well as in steady states. Detection of rotor cage defects in steady states is a comparative survey, which should be repeated from time to time in order to monitor the possible development of damage For standard drives that are powered from the network and work in open systems, by measuring the voltage following a unipolar flux, it is possible as necessary to make measurement and recording of motor speed, which usually is almost never provided under industrial conditions, also for the purpose of measurement of dynamic states and variability of rotation. The study shows that a simple in its construction, cheap coil can be a very useful diagnostic tool. Diagnosing machines using this method can be a valuable supplement, as well as confirmation of the results of studies carried out by other means. Keywords: unipolar flux, inter-turn short circuits, cage damage 100 Nr 5 Maj 2014 r.

Rys. 1. Rozpływ strumienia w silniku indukcyjnym [8] Rys. 3. Cewka zamontowana na badanym silniku Rys. 2. Rozpływ strumienia w silniku indukcyjnym [3, 8] Rys. 4. Uzwojenie silnika przygotowanego do realizacji zwarcia zwojowego własną zwartych zwojów. Prąd płynący przez zwarte uzwojenia jest źródłem pulsacji sił magnetomotorycznych, które wpływają na harmoniczne przestrzenne pola [8]. Zwarcia zwojowe powodują zmiany harmonicznych o częstotliwościach [4, 5, 8]: f ax sc = k fs + n(1 s)f s /p b (1) lub: f ax sc = k fs + n fr (2) gdzie: f s częstotliwość napięcia zasilającego; f r częstotliwość obrotowa wirnika w Hz; k rząd harmonicznej czasowej źródła zasilania; n = 1, 2, 3,, 2p b 1; n 2p b m; m = 1, 2,. W przypadku uszkodzenia klatki wirnika w widmie sygnału występują charakterystyczne częstotliwości [4, 5]: f ax bar = sf s (3) Można też spotkać się ze wzorami z prawą stroną w postaci [4]: f ax bar = (3 2s)f s (4) f ax bar = (5 4s)f s (5) Do badania strumienia poosiowego wykorzystujemy cewkę pomiarową umieszczoną na wale silnika jak najbliżej uzwojenia stojana. Jeśli pozwala na to budowa silnika, cewkę mocujemy do dekla silnika w jego wnętrzu, jeśli nie pozwala na to ilość miejsca umieszczamy ją na zewnątrz. Na rys. 2 przedstawiono miejsce zamontowania cewki pomiarowej. Cewka może być montowana na zewnątrz silnika zarówno od strony wentylatora, jak i od strony wału. W artykule oba te przypadki będą zilustrowane i zostaną przedstawione wyniki badań na silnikach, w których stwierdzono uszkodzenie stojana i klatki wirnika. 3. Badanie uszkodzeń stojana Do prób przeznaczono silnik indukcyjny 4 kw, 380 V(Y), w którym umożliwiono kontrolowane zwarcie 2 zwojów w fazie stojana. Do wychwytywania i pomiaru strumienia poosiowego użyto cewki bezrdzeniowej o około 500 zwojach nawiniętych cienkim drutem, którą przykładano na przemian w 2 miejscach silnika: wokół wału (od strony napędnej) i od strony wentylatora (przeciwnapędnej). Nr 5 Maj 2014 r. 101

Rys. 5. Przebieg napięcia w cewce pomiarowej wychwytującej strumień poosiowy podczas zwierania i rozwierania 2 zwojów fazy stojana Rys. 7. Przebieg napięcia w cewce pomiarowej podczas realizacji zwarć Rys. 6. Przebieg prądu w fazie, w której realizowano zwarcia 2 zwojów fazy stojana Po uruchomieniu silnika w ustalonym stanie pracy silnika przy pomocy wyłącznika na przemian zwierano i rozwierano pętlę zwarciową obejmującą 2 sąsiednie zwoje. Prąd fazy zwieranej oraz sygnał z cewki w postaci napięciowej zostały zarejestrowane przy pomocy karty pomiarowej DAQ. 3.1. Cewka przyłożona od strony wału Na rys. 5 widać znaczne, średnio 3-krotne skoki amplitudy strumienia w chwilach zwierania zwojów. Zmiany te w niewielkim stopniu przenosiły się na prąd fazowy (rys. 6), którego amplituda wzrastała ok. 1,22 razy, czyli o 22%. Należy dodać, że silnik pracował na biegu jałowym. W warunkach obciążenia silnika zmiany w prądzie byłyby niezauważalne. Zamontowanie cewki od strony napędnej przy zesprzęglonym silniku jest kłopotliwe i zabieg taki wymaga chwilowego od- Rys. 8. Przebieg prądu fazowego podczas realizacji zwarć sprzęglenia, chyba że cewka ma być umocowana na stałe i wówczas jest uzasadniony. Jeśli jednak pomiar ma być dokonany szybko, bez demontażu, podczas pracy silnika można cewkę przyłożyć do obudowy wentylatora rezultaty na rys. 7 i rys. 8. 3.2. Cewka przyłożona od strony wentylatora Rys. 7 pokazuje także bardzo wyraźne skokowe zmiany amplitudy strumienia: również 3-krotne w stosunku do poziomu przed zwarciem. Amplituda prądu wzrosła, podobnie jak poprzednio o 20%. Wnioski z obu pomiarów są takie, że cewka pomiarowa zapewnia silny sygnał dobrej jakości, który świadczy o zwarciu małej liczby zwojów, praktycznie niewykrywalnym przez zabezpieczenia prądowe, oraz że pomiar od strony wentylatora (na pierwszy rzut oka trudniejszy, bo rzekomo zakłócany przez wirujące łopatki) równie dobrze spełnia swe zadanie. 102 Nr 5 Maj 2014 r.

4. Badanie uszkodzeń klatki wirnika Badaniom poddano dwa trójfazowe silniki klatkowe 0,2 kw, 380 V, z których jeden był sprawny, a drugi miał kilka pękniętych prętów w wirniku. Cewkę pomiarową przykładano od strony wentylatora oraz od strony napędnej. 4.1. Cewka przyłożona od strony wentylatora Rys. 11 i rys. 12 pokazują różnice w poziomie strumienia poosiowego obu silników w stanie ustalonym: sprawnego i z defektem klatki przy usytuowaniu cewki od strony wentylatora. Tu silnik z uszkodzoną klatką wykazuje poziom sygnału 4,5 razy większy od silnika sprawnego. Rys. 9. Przebieg napięcia z cewki pomiarowej po odfiltrowaniu częstotliwości stojana 4.2. Cewka przyłożona od strony wału I w tym przypadku widać znaczną różnicę w poziomach strumieni. W tym przypadku poziom sygnału silnika uszkodzonego jest prawie 4-krotnie większy od sygnału silnika sprawnego. 4.3. Różna liczba uszkodzonych prętów klatki W laboratorium Politechniki Krakowskiej przeprowadzono badania na silnikach 0,8 kw. Badano cztery identyczne silniki SZJKe14a: jeden silnik zdrowy, trzy z uszkodzeniami prętów klatki odpowiednio 1, 2 i 3 pęknięte pręty. Widok cewki zamontowanej na obudowie badanych silników przedstawiono na rys. 15. Zarejestrowany sygnał bezpośrednio z cewki odfiltrowano filtrem dolnopasmowym o częstotliwości odcięcia 10 Hz. W tabeli 1 zestawiono wartości skuteczne sygnału z cewki oraz sygnału odfiltrowanego. Dla sygnału odfiltrowanego widać wyraźną zależność poziomu sygnału od liczby uszkodzonych prętów. Tabela 1. Zestawienie wartości skutecznych sygnału diagnostycznego Silnik/Sygnał Całkowity [mv] Odfiltrowany [mv] Rys. 10. Przebieg napięcia z cewki pomiarowej po odfiltrowaniu składowych od wirnika Interesujące będzie stwierdzenie, która ze składowych strumienia: pochodząca od stojana czy od wirnika, podlega zmianom wywołanym zwarciami. W tym celu dokonano filtracji, uzyskując przebiegi: pozbawione składowej 50 Hz pochodzącej od stojana (rys. 9); pozbawione składowych pochodzących od wirnika, w tym f r = s fs (rys. 10). Wnioski są następujące: największym relatywnie zmianom wywołanym zwarciami podlega składowa strumienia pochodząca od wirnika (rys. 9), choć amplitudy pików wywołanych zwarciami są rzędu miliwoltów; na podstawie rys. 10 można stwierdzić, że również sygnał pochodzący od stojana jest dobrym i stosunkowo pewnym sygnałem do wyzwolenia zabezpieczenia reagującego na zwarcie zwojowe, bowiem piki wywołane zwarciami są rzędu woltów. Symetryczny 42,7 1,3 Defekt 1 pręta 299,5 8,4 Defekt 2 prętów 301,5 9,7 Defekt 3 prętów 262,1 13,6 5. Możliwości zastosowania metody w diagnostyce napędów przemysłowych W warunkach przemysłowych prawie nigdy nie rejestruje się prędkości obrotowej maszyn elektrycznych zasilanych z sieci. Jednak dla celów diagnostycznych pomiar prędkości nieraz jest niezbędny. Podobnie dla potrzeb rejestracji zmian momentu na wale silnika, na przykład podczas zabiegów gwarancyjnych, reklama Nr 5 Maj 2014 r. 103

Rys. 11. Strumień poosiowy silnika sprawnego mierzony od strony wentylatora Rys. 13. Strumień poosiowy silnika sprawnego mierzony od strony napędnej Rys. 12. Strumień poosiowy silnika uszkodzonego mierzony od strony wentylatora konieczna jest rejestracja lub ewaluacja prędkości. Jeśli maszyna nie posiada prądnicy tachometrycznej czy obrotomierza impulsowego, zadanie to spełni analiza sygnału z cewki pomiarowej, przyłożonej od strony przeciwnapędnej lub uprzednio zamontowanej wewnątrz maszyny wokół wału lub czół. Poniżej przedstawiono odfiltrowany przebieg napięcia z cewki umieszczonej pod deklem wokół łożyska od strony przeciwnapędnej silnika 630 kw, 6 kv. Częstotliwość przebiegu równa jest zmieniającej się częstotliwości prądu wirnika: Rys. 14. Strumień poosiowy silnika uszkodzonego mierzony od strony napędnej T 1 = 1 / f 1 f 1 częstotliwość prądu stojana; T 2 = 1 / f 2 f 2 częstotliwość prądu wirnika. Zatem obroty silnika można wyrazić wzorem: n(t)=(60f 1 /p)[1 s(t)]= (60/p)[f 1 1/T 2 (t)] (8) Dla napędów standardowych (zasilanych z sieci, pracujących w układach otwartych, bez nagłych zmian obrotów) pomiar prędkości na podstawie strumienia unipolarnego wydaje się być wystarczająco dokładny. stąd f 2 = sf 1 (6) s = f 2 / f 1 = T 1 / T 2 (t) (7) 6. Podsumowanie W artykule przedstawiono zastosowania sygnału strumienia unipolarnego w diagnostyce maszyn prądu przemiennego. Pokazano, że prosta w swej konstrukcji, tania cewka może być 104 Nr 5 Maj 2014 r.

Rys. 15. Badany silnik z uszkodzonymi prętami klatki wirnika i przyłożoną cewką pomiarową Rys. 17. Odfiltrowany przebieg napięcia z cewki odpowiadającego strumieniowi wirnika Rys. 16. Silnik, w którym zabudowano cewkę bardzo przydatnym narzędziem diagnostycznym. Może służyć jako czujnik wykrywający bez zwłoki zwarcia zwojowe lub też jako urządzenie do pomiaru i porównywania poziomów degradacji klatki w czasie, wreszcie jako element układu do pomiaru bądź rejestracji prędkości obrotowej oraz momentu dynamicznego na wale silnika. 7. Literatura [1] Petryna J.: Zjawiska drganiowe w maszynach indukcyjnych ze zwarciami zwojowymi stojana. Kwartalnik Elektrotechnika ZN AGH, t. 5, z. 2, Kraków 1986. [2] Noga M., Petryna J.: Dynamic states in induction machines with internal asymmetries. TH Ilmenau Wiss. Zeitschr. 4/90. [3] Assaf T., Henao H., Capolino G.-A.: Simplified axial flux spectrum method to detect in-cipient stator inter-turn short-circuits in induction machine. 2004 IEEE International Symposium on Industrial Electronics, Volume 2, 4 7 May 2004, pp. 815 819. [4] Kowalski Cz.: Monitorowanie i diagnostyka uszkodzeń silników indukcyjnych z wykorzystaniem sieci neuronowych. Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław 2005. [5] Keysan O., Ertan H.B.: Higher Order Rotor Slot Harmonics for Rotor Speed & Position Estimation. 12th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM 2010, pp. 416 421. [6] Sinervo A., Laiho A., Arkkio A.: Low-Frequency Oscillation in Rotor Vibration of a Two-Pole Induction Machine With Extra Four-Pole Stator Winding. IEEE Transactions on Magnetics, Vol. 47, No. 9, September 2011, pp. 2292 2302. [7] Frosini L., Borin A., Girometta L., Venchi G.: Development of a leakage flux measurement system for condition monitoring of electrical drives. 2011 IEEE International Symposium on SDEM- PED, 5 8 Sept. 2011, pp. 356 363. [8] Nowak P.: Diagnostyka zwarć w uzwojeniach stojana trójfazowych silników indukcyjnych. Praca dyplomowa, Politechnika Krakowska, Kraków 2012. Praca została wykonana w ramach badań własnych autorów dzięki uprzejmości firmy EKO-ENERGIA z Krakowa, która udostępniła silniki do badań na swojej Stacji Prób. dr inż. J. Petryna, e-mail: jpetryna@pk.edu.pl; dr inż. M. Sułowicz, e-mail: pesulowi@cyf-kr.edu.pl; mgr inż. A. Duda, e-mail: aduda@pk.edu.pl; Politechnika Krakowska, Wydział Inżynierii Elektrycznej i Komputerowej, Instytut Elektromechanicznych Przemian Energii; mgr inż. K. Guziec, e-mail: office@senco.krakow.pl, SENCO Sp. z o.o. artykuł recenzowany reklama Nr 5 Maj 2014 r. 105