FE-MODELLING OF A BOLTED LAP CONNECTION USING A SIMPLIFIED BOLT MODEL

Podobne dokumenty
EXAMPLES OF CABRI GEOMETRE II APPLICATION IN GEOMETRIC SCIENTIFIC RESEARCH

TO ADVANCED MODELLING OF END PLATE JOINTS

Proposal of thesis topic for mgr in. (MSE) programme in Telecommunications and Computer Science

Lecture 18 Review for Exam 1

ANALIZA WYTĘŻENIA ZWOI GWINTU W POŁĄCZENIU ŚRUBA- NAKRĘTKA ANALYSIS OF THREAD COIL EFFORT IN THE SCREW NUT JOINT

WSTĘPNE BADANIA NOŚNOŚCI NA DOCISK ZAKŁADKOWYCH POŁĄCZEŃ NA SWORZNIE JEDNOSTRONNE

Optymalizacja konstrukcji wymiennika ciepła

IDENTYFIKACJA I ANALIZA PARAMETRÓW GEOMETRYCZNYCH I MECHANICZNYCH KOŚCI MIEDNICZNEJ CZŁOWIEKA

SHEAR LAG EFFECT IN THE NUMERICAL EXPERIMENT

Rozpoznawanie twarzy metodą PCA Michał Bereta 1. Testowanie statystycznej istotności różnic między jakością klasyfikatorów

ISSUES OF ALTERNATING LOAD IN DESIGN OF COLD-FORMED STEEL FRAMES WITH LAP JOINTS

POLITECHNIKA WARSZAWSKA. Wydział Zarządzania ROZPRAWA DOKTORSKA. mgr Marcin Chrząścik

DUAL SIMILARITY OF VOLTAGE TO CURRENT AND CURRENT TO VOLTAGE TRANSFER FUNCTION OF HYBRID ACTIVE TWO- PORTS WITH CONVERSION

ASPEKTY PROJEKTOWANIA PASOWAŃ W POŁĄCZENIACH OSIOWOSYMETRYCZNYCH

Knovel Math: Jakość produktu

DM-ML, DM-FL. Auxiliary Equipment and Accessories. Damper Drives. Dimensions. Descritpion

Fig 5 Spectrograms of the original signal (top) extracted shaft-related GAD components (middle) and

INSPECTION METHODS FOR QUALITY CONTROL OF FIBRE METAL LAMINATES IN AEROSPACE COMPONENTS

ROZPRAWY NR 128. Stanis³aw Mroziñski

MOMENT RESISTANCE OF I-SECTION END-PLATE ROOF GIRDER SPLICES; A CASE STUDY

Nieliniowość warstwy stykowej między elementami łączonymi w połączeniu wielośrubowym a napięcie wstępne śrub

ZESZYTY NAUKOWE NR 5(77) AKADEMII MORSKIEJ W SZCZECINIE. Symulacyjne wyznaczanie charakterystyk statycznych dla typoszeregu odbojnic cylindrycznych

PARAMETRYCZNA ANALIZA PODATNOŚCI ŚRUBOWYCH STYKÓW DOCZOŁOWYCH DWUTEOWYCH BELEK STALOWYCH METODĄ ELEMENTÓW SKOŃCZONYCH

SYMULACJA TŁOCZENIA ZAKRYWEK KORONKOWYCH SIMULATION OF CROWN CLOSURES FORMING

Metody obliczania izolacyjności akustycznej między pomieszczeniami w budynku według PN-EN :2002 i PN-EN :2002

MODELOWANIE MES STRUKTUR O KARBACH SZEREGOWYCH FEM MODELING OF STRUCTURES WITH SERIAL NOTCHES


Network Services for Spatial Data in European Geo-Portals and their Compliance with ISO and OGC Standards

MODELOWANIE POŁĄCZEŃ TYPU SWORZEŃ OTWÓR ZA POMOCĄ MES BEZ UŻYCIA ANALIZY KONTAKTOWEJ

4. EKSPLOATACJA UKŁADU NAPĘD ZWROTNICOWY ROZJAZD. DEFINICJA SIŁ W UKŁADZIE Siła nastawcza Siła trzymania

Politechnika Krakowska im. Tadeusza Kościuszki. Karta przedmiotu. obowiązuje studentów rozpoczynających studia w roku akademickim 2015/2016

PRACE INSTYTUTU ODLEWNICTWA TRANSACTIONS OF FOUNDRY RESEARCH INSTITUTE

Numeryczna i doświadczalna analiza naprężeń w kołowych perforowanych płytach swobodnie podpartych obciążonych centralnie siłą skupioną

XXIII Konferencja Naukowa POJAZDY SZYNOWE 2018

BADANIA MODELOWE ZŁĄCZA CIERNEGO OBCIĄŻONEGO UDAREM MASY

Akademia Morska w Szczecinie. Wydział Mechaniczny

TECHNICAL CATALOGUE WHITEHEART MALLEABLE CAST IRON FITTINGS EE

ANALIZA TECHNICZNO-EKONOMICZNA POŁĄCZEŃ NIEROZŁĄCZNYCH

APPLICATION OF THE FINITE-ELEMENT METHOD FOR DETERMINING THE STIFFNESS OF ROLLING BEARINGS


Metal constructions. Nazwa przedmiotu (course title) II.B.1. Kod przedmiotu (course code) II.B.2

BADANIA NUMERYCZNE I DOŚWIADCZALNE NOŚNOŚCI GRANICZNEJ BELEK TRÓJWARSTWOWYCH

WPŁYW OBCIĄŻENIA TRAMWAJU NA PRZEMIESZCZENIE ELEMENTÓW ELASTYCZNEGO KOŁA TRAMWAJOWEGO

OPTYMALIZACJA KONSTRUKCJI WZMOCNIEŃ ELEMENTÓW NOŚNYCH MASZYN I URZĄDZEŃ

OPORY W RUCHU OSCYLACYJNYM MECHANIZMÓW MASZYN GÓRNICZYCH

ZASTOSOWANIE RÓWNANIA BOUSSINESQUE A DO OKREŚLANIA NAPRĘŻEŃ W GLEBIE WYWOŁANYCH ODDZIAŁYWANIEM ZESTAWÓW MASZYN

NIESTACJONARNY PRZEPŁYW CIEPŁA W TŁOKU DOŁADOWANEGO SILNIKA Z ZAPŁONEM SAMOCZYNNYM

Auditorium classes. Lectures

Praktyczne aspekty wymiarowania belek żelbetowych podwójnie zbrojonych w świetle PN-EN

SYMULACJA NUMERYCZNA KRZEPNIĘCIA KIEROWANEGO OCHŁADZALNIKAMI ZEWNĘTRZNYMI I WEWNĘTRZNYMI

Cracow University of Economics Poland. Overview. Sources of Real GDP per Capita Growth: Polish Regional-Macroeconomic Dimensions

Opis Przedmiotu Zamówienia oraz kryteria oceny ofert. Części nr 10

SG-MICRO... SPRĘŻYNY GAZOWE P.103

THE INFLUENCE OF THE ENGINE LOAD ON VALUE AND TEMPERATURE DISTRIBUTION IN THE VALVE SEATS OF TURBO DIESEL ENGINE

OpenPoland.net API Documentation

ANALIZA PROCESU WPROWADZANIA NAPIĘCIA WSTĘPNEGO W NIESYMETRYCZNYM, NIELINIOWYM POŁĄCZENIU WIELOŚRUBOWYM

TTIC 31210: Advanced Natural Language Processing. Kevin Gimpel Spring Lecture 8: Structured PredicCon 2

Hard-Margin Support Vector Machines

NUMERYCZNA ANALIZA ROZKŁADÓW NACISKU WYSTĘPUJĄCYCH W STANDARDOWYCH WĘZŁACH TRIBOLOGICZNYCH

IDENTYFIKACJA PARAMETRÓW CHARAKTERYZUJĄCYCH OBCIĄŻENIE SEKCJI OBUDOWY ZMECHANIZOWANEJ SPOWODOWANE DYNAMICZNYM ODDZIAŁYWANIEM GÓROTWORU

Tytuł pracy w języku angielskim: Microstructural characterization of Ag/X/Ag (X = Sn, In) joints obtained as the effect of diffusion soledering.

TRANSPORT W RODZINNYCH GOSPODARSTWACH ROLNYCH

ANALIZA NUMERYCZNA SWORZNIOWEGO POŁĄCZENIA STOSOWANEGO W KONSTRUKCJACH WIELOCZŁONOWYCH

Wpływ nieliniowości warstwy stykowej między elementami łączonymi w połączeniu wielośrubowym na wartości napięcia wstępnego śrub

Symulacyjne badanie wpływu przemieszczeń podpór na naprężenia w kratownicowej konstrukcji dachowej

ZACHODNIOPOMORSKI UNIWERSYTET TECHNOLOGICZNY

OBCIĄŻENIA TERMICZNE W ZESPOLONYCH DŹWIGARACH MOSTOWYCH THERMAL LOADS IN BRIDGE COMPOSITE STRUCTURES

Zarządzanie sieciami telekomunikacyjnymi

QUANTITATIVE AND QUALITATIVE CHARACTERISTICS OF FINGERPRINT BIOMETRIC TEMPLATES

PLANY I PROGRAMY STUDIÓW

Wysokowytrzymałe zestawy śrubowe HV High strength HV-sets

POPRAWKA do POLSKIEJ NORMY

Struktury proponowane dla unikalnych rozwiązań architektonicznych.

Post low voltage insulators

WENTYLATORY PROMIENIOWE SINGLE-INLET DRUM BĘBNOWE JEDNOSTRUMIENIOWE CENTRIFUGAL FAN

POLITECHNIKA CZĘSTOCHOWSKA WYDZIAŁ BUDOWNICTWA KIERUNEK: BUDOWNICTWO KARTA OPISU PRZEDMIOTU

Mgr inż. Krzysztof KRAWIEC. Rozprawa doktorska. Streszczenie

Numeryczna analiza naprężenia kołowych płyt perforowanych obciążonych siłą skupioną

WSPÓŁCZYNNIK PRACY ZŁĄCZA CIERNEGO GÓRNICZEJ, KORYTARZOWEJ OBUDOWY PODATNEJ

ROZPRAWA DOKTORSKA. Model obliczeniowy ogrzewań mikroprzewodowych

Wysokowytrzymałe zestawy śrubowe HV High strength HV-sets

RADIO DISTURBANCE Zakłócenia radioelektryczne

KOMPUTEROWE MODELOWANIE I OBLICZENIA WYTRZYMAŁOŚCIOWE ZBIORNIKÓW NA GAZ PŁYNNY LPG

METODA OGÓLNEJ OCENY STANU ŚRODO- WISKA OBSZARÓW WIEJSKICH NA PODSTAWIE INFORMACJI Z BANKU DANYCH REGIONALNYCH GUS I OSZACOWAŃ PROGRAMU EMEP

Outline of a method for fatigue life determination for selected aircraft s elements

DOI: / /32/37

ANALYSIS OF LOCAL INFLUENCES IN STRUCTURAL DETAILS OF THE BRIDGES

Formularz recenzji magazynu. Journal of Corporate Responsibility and Leadership Review Form

The analysis of the energy demand for heating and cooling of the house built on the basis of the traditional Canadian wood-frame construction

The Lorenz System and Chaos in Nonlinear DEs

Instrumenty i efekty wsparcia Unii Europejskiej dla regionalnego rozwoju obszarów wiejskich w Polsce

Forested areas in Cracow ( ) evaluation of changes based on satellite images 1 / 31 O

RADIO DISTURBANCE Zakłócenia radioelektryczne

A R C H I V E S O F M E T A L L U R G Y A N D M A T E R I A L S Volume Issue 2 DOI: /amm

European Crime Prevention Award (ECPA) Annex I - new version 2014

SPIS TREŚCI SPIS WAŻNIEJSZYCH OZNACZEŃ WSTĘP KRÓTKA CHARAKTERYSTYKA SEKTORA ENERGETYCZNEGO W POLSCE... 14

ANALIZA BELKI DREWNIANEJ W POŻARZE

Wykaz linii kolejowych, które są wyposażone w urządzenia systemu ETCS

WYZNACZANIE SZTYWNOŚCI SKRĘTNEJ PRZEKŁADNI FALOWEJ DETERMINATION OF TORSIONAL STIFFNESS OF HARMONIC DRIVE

Latent Dirichlet Allocation Models and their Evaluation IT for Practice 2016

Transkrypt:

MODELOWANIE INŻYNIERSKIE 2017 nr 62, ISSN 1896-771X FE-MODELLING OF A BOLTED LAP CONNECTION USING A SIMPLIFIED BOLT MODEL Rafał Grzejda Katedra Mechaniki i PKM, Zachodniopomorski Uniwersytet Technologiczny w Szczecinie rafal.grzejda@zut.edu.pl Summary Modelling and calculations of a bolted lap connection are presented. Analysis of forces acting on the bolts based on the theoretical formulas and using the finite element method (FEM) is performed. In the case of theoretical calculations the recommendations given in the standard PN-EN 1993-1-8 are applied. For a case of numerical calculations a simplified model of the bolt is used. The obtained results of calculations are checked in terms of fulfilment of the adopted criterion for load capacity of the connection. Selected results of simulation studies of the bolted lap connection FEM-model in the form of a displacement map and a reduced stress map of the model under specified external load are pointed out. Based on the comparison of the theoretical and numerical analyses results, usefulness of the simplified bolt model for calculations of operational forces in the bolts in bolted lap connections is determined. Keywords: bolted lap connection, FE-modelling, Eurocode 3 MODELOWANIE MES ZAKŁADKOWEGO POŁĄCZENIA ŚRUBOWEGO Z ZASTOSOWANIEM UPROSZCZONEGO MODELU ŚRUBY Streszczenie Przedstawiono modelowanie i obliczenia zakładkowego połączenia śrubowego. Przeprowadzono analizę sił występujących w śrubach na podstawie wzorów teoretycznych oraz za pomocą metody elementów skończonych (MES). W obliczeniach teoretycznych zastosowano zalecenia podane w normie PN-EN 1993-1-8. W obliczeniach numerycznych wykorzystano uproszczony model śruby. Otrzymane wyniki sprawdzono pod kątem spełnienia przyjętego kryterium nośności połączenia. Przedstawiono wybrane wyniki badań numerycznych modelu połączenia w postaci mapy przemieszczeń i mapy naprężeń zredukowanych modelu wywołanych zadanym obciążeniem zewnętrznym. Na podstawie porównania wyników obliczeń teoretycznych oraz wyników obliczeń numerycznych określono przydatność uproszczonego modelu śruby do obliczeń sił roboczych w śrubach w połączeniach zakładkowych. Słowa kluczowe: zakładkowe połączenie śrubowe, modelowanie MES, Eurokod 3 1. INTRODUCTION Depending on the aim of modelling, bolted lap connections may be calculated according to various methods. For engineering design of this type of connections the standards PN-EN 1993-1-1 [17] and PN-EN 1993-1-8 [18] are appropriable. However, they cannot be used for connections loaded by dynamic forces [2, 11]. In more complex analyses it is common to use the finite element method and three-dimensional models of the connections. In these cases the problems of both single-bolted lap connections [3, 4, 20, 21, 24, 25] and multi-bolted lap connections [1, 9, 19, 22, 23] are taken into account. Between the mentioned calculation methods, the FEmodelling bolted lap connections using simplified bolt models can be positioned. These include models such as: 24

Rafał Grzejda - rigid elements without the bolt head [10, 12], - rigid body bolt models with a flexible shank of the bolt and a rigid bolt head [7, 16], - beam elements [13, 14, 15], - spider bolt elements [5, 6]. Application of simplified bolt models enables to achieve satisfactory calculation results in a much shorter time than in the case of entire three-dimensional models. Pursuant to the standard [18], bolted lap connections can be subdivided as follows: - bearing type connections of category A, - slip-resistant connections at the serviceability limit state of category B, - slip-resistant connections at the ultimate limit state of category C. Bolted lap connections of category B and C in this classification belong to the connections that are preloaded by the force Fm, which is defined according to the formula [2] where: =0.7 (1) fub the ultimate tensile strength for bolts [MPa], As the tensile stress area of the bolt [mm2]. Bolted lap connections can also be divided on the grounds of their geometry. In this classification the following types of the connections can be distinguished: - simple connections (single-shear joints and doubleshear joints), - complex connections (beam-column joints). In the paper the theme of modelling bolted lap connections using the Midas NFX 2014 FEM program has been undertaken. The aim of the study is assessment and evaluation the usefulness of a simplified model of the bolt embedded in this system to load analysis of bolted lap connections. The results of numerical calculations are compared with results of calculations under the standards [17, 18]. 2. DESCRIPTION OF THE TESTED BOLTED LAP CONNECTION The subject of research is a complex bolted lap connection show in Fig.1, which has been designed as a slipresistant connection at the serviceability limit state of category B. It is created with a cantilever beam mounted to a column by means of four M20 bolts made in the mechanical property class 10.9. The joined elements are performed by using channel sections 300E made of S235 structural steel. The connection is loaded by the external force Ft equal to 48 kn. Calculations were made for both the non-preloaded connection and the connection preloaded by the force Fm equal to 171.5 kn designated from the formula (1). Fig. 1. Beam to column bolted lap connection The fasteners are modelled as hybrid components consist of (for a review, see [8]): - a flexible shank of the bolt in the form of a beam, - rigid head of the bolt and a rigid nut (Fig. 2). Fig. 2. Model of the bolt For modelling of a contact zone between the cantilever beam and the column general surface to surface contact elements available in the Midas NFX 2014 program are applied. The parameters of the contact elements are collected in Tab. 1. In the data table the following designations are used: - kn the coefficient of the normal contact stiffness, - kt the coefficient of the tangent contact stiffness, - µ the coefficient of the static friction. The FEM model of the bolted lap connection is shown in Fig. 3. Tab. 1. Parameters of the contact elements Parameter Value kn 1.0 kt 0.1 µ 0.4 Ft Rigid head Flexible shank Rigid nut 25

FE-MODELLING OF A BOLTED LAP CONNECTION USING A SIMPLIFIED BOLT MODEL A A 4 3 2 1 Fig. 3. FEM model of the beam to column tion bolted lap connec- 3. CALCULATION RESULTS In the case of the analysed connection the most exerted fasteners are fasteners marked with numbers 1 and 2 (Fig. 3). In the next part of the paper the discussion will be limited to the fastener No. 1. The maximum value of the operational force in the bolt No. 1 determined on the basis of the formulas given in the standard [18] is 81.6 kn (for a review, see [11]). This value of the operational force fulfils the condition of capacity of the bolt on the pressure [18]. The value of this operational force by the FEM model of the connection is equal to 68.9 kn. It is therefore lower compared to the value for the theoretical model by about 16 %. The difference in the force values can be explained by the fact that in the theoretical calculations it is assumed that the bolted lap connection is a rigid connection. However, in the FEM calculations the flexibility of contact zone between the cantilever beam and the column is taken into account. Increasing the rigidity of the contact joint in the FEM model of the connection by changing the coefficient of the normal contact stiffness kn to the value of 1.45 and the coeffi- cient of the tangent contact stiffness kt to the value of 0.145 one achieves the operational force in the bolt No. 1 equal to 81.9 kn. After performing the calculations in a FEM program it is also possible to generate maps of displacements and reduced stresses for a given system. It is an undoubted advantage of this type of calculations in comparison with theoretical calculations. An example of the distriof the preloaded bution of the resultant displacements and externally loaded bolted lap connection FEM model in shown in Fig. 4. Fig. 4. Distribution of the resultant displacements of the preloaded and externally loaded bolted lap connection FEM model In contrast, Fig. 5 shows the distribution of the reduced stresses of the connection FEM model for the same load case. The maximum value of the reduced stress amounts to 256.3 MPA and does not exceed the ultimate tensile strength for the steel adopted for the cantilever beam and the column. Fig. 5. Distribution of the reduced stresses of the preloaded and externally loaded bolted lap connection FEM model 4. CONCLUSIONS Analysing the results of work the following conclusions were put forward: 1. If the FEM tests of bolted lap connections are car- parameters for ex- ried out to study the selected ample in order to determinee forces acting on the bolts and joined elements it is proposed to use simplified models of the bolts and the connections. This considerably increases the efficiency of the modelling and shortens the time of numerical calcu- (which are included lations. 2. The use of theoretical formulas in the standards) for the appointment of operational forces in the bolts can lead to results inconsistent with reality. 26

Rafał Grzejda References 1. Alibrahemy M., Durif S., Bressolette P., Bouchaïr A.: Finite element analysis of cover plate joint under ultimate loading. Procedia Engineering 2016, Vol. 156, p. 16-23. 2. Biegus A.: Obliczanie nośności śrub według PN-EN 1993-1-8. Inżynieria i Budownictwo 2008, nr 3, s. 113-118. 3. Chung K.F., Ip K.H.: Finite element investigation on the structural behaviour of cold-formed steel bolted connections. Engineering Structures 2001, Vol. 23, No. 9, p. 1115-1125. 4. Draganić H., Dokšanović T., Markulak D.: Investigation of bearing failure in steel single bolt lap connections. Journal of Constructional Steel Research 2014, Vol. 98, p. 59-72. 5. Grzejda R.: Modelling nonlinear multi-bolted connections: A case of the assembly condition. In: Proc. of the 15th International Scientific Conference Engineering for Rural Development 2016, Jelgava: Latvia University of Agriculture, 2016, p. 329-335. 6. Grzejda R.: Modelling nonlinear multi-bolted connections: A case of the operational condition. In: Proc. of the 15th International Scientific Conference Engineering for Rural Development 2016, Jelgava: Latvia University of Agriculture, 2016, p. 336-341. 7. Grzejda R.: Modelling nonlinear preloaded multi-bolted systems on the operational state. Engineering Transactions 2016, Vol. 64, No. 4, p. 525-531. 8. Grzejda R.: New method of modelling nonlinear multi-bolted systems. In: Advances in Mechanics: Theoretical, Computational and Interdisciplinary Issues, Proc. of the 3rd Polish Congress of Mechanics (PCM) and 21st International Conference on Computer Methods in Mechanics (CMM), Leiden: CRC Press/Balkema, 2016, p. 213-216. 9. Ju S.-H., Fan C.-Y., Wu G.H.: Three-dimensional finite elements of steel bolted connections. Engineering Structures 2004, Vol. 26, No. 3, p. 403-413. 10. Kim T.S., Kuwamura H.: Finite element modeling of bolted connections in thin-walled stainless steel plates under static shear. Thin-Walled Structures 2007, Vol. 45, No. 4, p. 407-421. 11. Kozłowski A., Pisarek Z., Wierzbicki S.: Projektowanie zakładkowych połączeń śrubowych według PN-EN 1993-1-1 i PN-EN 1993-1-8. Inżynieria i Budownictwo 2008, nr 9, s. 496-500. 12. Može P., Beg D.: A complete study of bearing stress in single bolt connections. Journal of Constructional Steel Research 2014, Vol. 95, p. 126-140. 13. Naruse T., Kawasaki T., Hattori T.: Simple modelling and strength evaluation methods for bolt joints using shell elements and beam elements (1st Report, Modelling method). Journal of Computational Science and Technology 2009, Vol. 3, No. 1, p. 22-33. 14. Nycz D.B.: Modelowanie końcówek odcinka bariery SP-05/2 do zastosowania w symulacji testów zderzeniowych. Modelowanie Inżynierskie 2016, nr 60, s. 44-51. 15. Nycz D.B.: Modelowanie złączy śrubowych segmentów prowadnicy typu B bariery drogowej SP-05/2. Modelowanie Inżynierskie 2016, nr 58, s. 105-112. 16. Palenica P., Powałka B., Grzejda R.: Assessment of modal parameters of a building structure model. Springer Proceedings in Mathematics & Statistics 2016, Vol. 181, p. 319-325. 17. PN-EN 1993-1-1:2006. Eurokod 3: Projektowanie konstrukcji stalowych, Część 1-1: Reguły ogólne i reguły dla budynków. 18. PN-EN 1993-1-8:2006. Eurokod 3: Projektowanie konstrukcji stalowych, Część 1-8: Projektowanie węzłów. 19. Puchała K., Szymczyk E., Jachimowicz J.: FEM design of composite metal joint for bearing failure analysis. Przegląd Mechaniczny 2015, nr 2, s. 33-41. 20. Raju K.P., Bodjona K., Lim G.-H., Lessard L.: Improving load sharing in hybrid boned/bolted composite joints using an interference-fit bolt. Composite Structures 2016, Vol. 149, p. 329-338. 21. Reid J.D., Hiser N.R.: Detailed modeling of bolted joints with slippage. Finite Elements in Analysis and Design 2005, Vol. 41, No. 6, p. 547-562. 22. Salih E.L., Gardner L., Nethercot D.A.: Numerical investigation of net section failure in stainless steel bolted connections. Journal of Constructional Steel Research 2010, Vol. 66, No. 12, p. 1455-1466. 27

FE-MODELLING OF A BOLTED LAP CONNECTION USING A SIMPLIFIED BOLT MODEL 23. Salih E.L., Gardner L., Nethercot D.A.: Numerical study of stainless steel gusset plate connections. Engineering Structures 2013, Vol. 49, p. 448-464. 24. Tajeuna T.A.D., Légeron F., Labossière P., Demers M., Langlois S.: Effect of geometrical parameters of alumi- composite joint num-to-steel bolted connections. Engineering Structures 2015, Vol. 102, p. 344-357. 25. Wang Z., Zhou S., Zhang J., Wu X., Zhou L.: Progressive failure analysis of bolted single-lap based on extended finite element method. Materials & Design 2012, Vol. 37, p. 582-588. Artykuł dostępny na podstawie licencji Creative Commons Uznanie autorstwa 3.0 Polska. http://creativecommons.org/licenses/by/3.0/pl 28