MODELOWANIE INŻYNIERSKIE 2017 nr 62, ISSN 1896-771X FE-MODELLING OF A BOLTED LAP CONNECTION USING A SIMPLIFIED BOLT MODEL Rafał Grzejda Katedra Mechaniki i PKM, Zachodniopomorski Uniwersytet Technologiczny w Szczecinie rafal.grzejda@zut.edu.pl Summary Modelling and calculations of a bolted lap connection are presented. Analysis of forces acting on the bolts based on the theoretical formulas and using the finite element method (FEM) is performed. In the case of theoretical calculations the recommendations given in the standard PN-EN 1993-1-8 are applied. For a case of numerical calculations a simplified model of the bolt is used. The obtained results of calculations are checked in terms of fulfilment of the adopted criterion for load capacity of the connection. Selected results of simulation studies of the bolted lap connection FEM-model in the form of a displacement map and a reduced stress map of the model under specified external load are pointed out. Based on the comparison of the theoretical and numerical analyses results, usefulness of the simplified bolt model for calculations of operational forces in the bolts in bolted lap connections is determined. Keywords: bolted lap connection, FE-modelling, Eurocode 3 MODELOWANIE MES ZAKŁADKOWEGO POŁĄCZENIA ŚRUBOWEGO Z ZASTOSOWANIEM UPROSZCZONEGO MODELU ŚRUBY Streszczenie Przedstawiono modelowanie i obliczenia zakładkowego połączenia śrubowego. Przeprowadzono analizę sił występujących w śrubach na podstawie wzorów teoretycznych oraz za pomocą metody elementów skończonych (MES). W obliczeniach teoretycznych zastosowano zalecenia podane w normie PN-EN 1993-1-8. W obliczeniach numerycznych wykorzystano uproszczony model śruby. Otrzymane wyniki sprawdzono pod kątem spełnienia przyjętego kryterium nośności połączenia. Przedstawiono wybrane wyniki badań numerycznych modelu połączenia w postaci mapy przemieszczeń i mapy naprężeń zredukowanych modelu wywołanych zadanym obciążeniem zewnętrznym. Na podstawie porównania wyników obliczeń teoretycznych oraz wyników obliczeń numerycznych określono przydatność uproszczonego modelu śruby do obliczeń sił roboczych w śrubach w połączeniach zakładkowych. Słowa kluczowe: zakładkowe połączenie śrubowe, modelowanie MES, Eurokod 3 1. INTRODUCTION Depending on the aim of modelling, bolted lap connections may be calculated according to various methods. For engineering design of this type of connections the standards PN-EN 1993-1-1 [17] and PN-EN 1993-1-8 [18] are appropriable. However, they cannot be used for connections loaded by dynamic forces [2, 11]. In more complex analyses it is common to use the finite element method and three-dimensional models of the connections. In these cases the problems of both single-bolted lap connections [3, 4, 20, 21, 24, 25] and multi-bolted lap connections [1, 9, 19, 22, 23] are taken into account. Between the mentioned calculation methods, the FEmodelling bolted lap connections using simplified bolt models can be positioned. These include models such as: 24
Rafał Grzejda - rigid elements without the bolt head [10, 12], - rigid body bolt models with a flexible shank of the bolt and a rigid bolt head [7, 16], - beam elements [13, 14, 15], - spider bolt elements [5, 6]. Application of simplified bolt models enables to achieve satisfactory calculation results in a much shorter time than in the case of entire three-dimensional models. Pursuant to the standard [18], bolted lap connections can be subdivided as follows: - bearing type connections of category A, - slip-resistant connections at the serviceability limit state of category B, - slip-resistant connections at the ultimate limit state of category C. Bolted lap connections of category B and C in this classification belong to the connections that are preloaded by the force Fm, which is defined according to the formula [2] where: =0.7 (1) fub the ultimate tensile strength for bolts [MPa], As the tensile stress area of the bolt [mm2]. Bolted lap connections can also be divided on the grounds of their geometry. In this classification the following types of the connections can be distinguished: - simple connections (single-shear joints and doubleshear joints), - complex connections (beam-column joints). In the paper the theme of modelling bolted lap connections using the Midas NFX 2014 FEM program has been undertaken. The aim of the study is assessment and evaluation the usefulness of a simplified model of the bolt embedded in this system to load analysis of bolted lap connections. The results of numerical calculations are compared with results of calculations under the standards [17, 18]. 2. DESCRIPTION OF THE TESTED BOLTED LAP CONNECTION The subject of research is a complex bolted lap connection show in Fig.1, which has been designed as a slipresistant connection at the serviceability limit state of category B. It is created with a cantilever beam mounted to a column by means of four M20 bolts made in the mechanical property class 10.9. The joined elements are performed by using channel sections 300E made of S235 structural steel. The connection is loaded by the external force Ft equal to 48 kn. Calculations were made for both the non-preloaded connection and the connection preloaded by the force Fm equal to 171.5 kn designated from the formula (1). Fig. 1. Beam to column bolted lap connection The fasteners are modelled as hybrid components consist of (for a review, see [8]): - a flexible shank of the bolt in the form of a beam, - rigid head of the bolt and a rigid nut (Fig. 2). Fig. 2. Model of the bolt For modelling of a contact zone between the cantilever beam and the column general surface to surface contact elements available in the Midas NFX 2014 program are applied. The parameters of the contact elements are collected in Tab. 1. In the data table the following designations are used: - kn the coefficient of the normal contact stiffness, - kt the coefficient of the tangent contact stiffness, - µ the coefficient of the static friction. The FEM model of the bolted lap connection is shown in Fig. 3. Tab. 1. Parameters of the contact elements Parameter Value kn 1.0 kt 0.1 µ 0.4 Ft Rigid head Flexible shank Rigid nut 25
FE-MODELLING OF A BOLTED LAP CONNECTION USING A SIMPLIFIED BOLT MODEL A A 4 3 2 1 Fig. 3. FEM model of the beam to column tion bolted lap connec- 3. CALCULATION RESULTS In the case of the analysed connection the most exerted fasteners are fasteners marked with numbers 1 and 2 (Fig. 3). In the next part of the paper the discussion will be limited to the fastener No. 1. The maximum value of the operational force in the bolt No. 1 determined on the basis of the formulas given in the standard [18] is 81.6 kn (for a review, see [11]). This value of the operational force fulfils the condition of capacity of the bolt on the pressure [18]. The value of this operational force by the FEM model of the connection is equal to 68.9 kn. It is therefore lower compared to the value for the theoretical model by about 16 %. The difference in the force values can be explained by the fact that in the theoretical calculations it is assumed that the bolted lap connection is a rigid connection. However, in the FEM calculations the flexibility of contact zone between the cantilever beam and the column is taken into account. Increasing the rigidity of the contact joint in the FEM model of the connection by changing the coefficient of the normal contact stiffness kn to the value of 1.45 and the coeffi- cient of the tangent contact stiffness kt to the value of 0.145 one achieves the operational force in the bolt No. 1 equal to 81.9 kn. After performing the calculations in a FEM program it is also possible to generate maps of displacements and reduced stresses for a given system. It is an undoubted advantage of this type of calculations in comparison with theoretical calculations. An example of the distriof the preloaded bution of the resultant displacements and externally loaded bolted lap connection FEM model in shown in Fig. 4. Fig. 4. Distribution of the resultant displacements of the preloaded and externally loaded bolted lap connection FEM model In contrast, Fig. 5 shows the distribution of the reduced stresses of the connection FEM model for the same load case. The maximum value of the reduced stress amounts to 256.3 MPA and does not exceed the ultimate tensile strength for the steel adopted for the cantilever beam and the column. Fig. 5. Distribution of the reduced stresses of the preloaded and externally loaded bolted lap connection FEM model 4. CONCLUSIONS Analysing the results of work the following conclusions were put forward: 1. If the FEM tests of bolted lap connections are car- parameters for ex- ried out to study the selected ample in order to determinee forces acting on the bolts and joined elements it is proposed to use simplified models of the bolts and the connections. This considerably increases the efficiency of the modelling and shortens the time of numerical calcu- (which are included lations. 2. The use of theoretical formulas in the standards) for the appointment of operational forces in the bolts can lead to results inconsistent with reality. 26
Rafał Grzejda References 1. Alibrahemy M., Durif S., Bressolette P., Bouchaïr A.: Finite element analysis of cover plate joint under ultimate loading. Procedia Engineering 2016, Vol. 156, p. 16-23. 2. Biegus A.: Obliczanie nośności śrub według PN-EN 1993-1-8. Inżynieria i Budownictwo 2008, nr 3, s. 113-118. 3. Chung K.F., Ip K.H.: Finite element investigation on the structural behaviour of cold-formed steel bolted connections. Engineering Structures 2001, Vol. 23, No. 9, p. 1115-1125. 4. Draganić H., Dokšanović T., Markulak D.: Investigation of bearing failure in steel single bolt lap connections. Journal of Constructional Steel Research 2014, Vol. 98, p. 59-72. 5. Grzejda R.: Modelling nonlinear multi-bolted connections: A case of the assembly condition. In: Proc. of the 15th International Scientific Conference Engineering for Rural Development 2016, Jelgava: Latvia University of Agriculture, 2016, p. 329-335. 6. Grzejda R.: Modelling nonlinear multi-bolted connections: A case of the operational condition. In: Proc. of the 15th International Scientific Conference Engineering for Rural Development 2016, Jelgava: Latvia University of Agriculture, 2016, p. 336-341. 7. Grzejda R.: Modelling nonlinear preloaded multi-bolted systems on the operational state. Engineering Transactions 2016, Vol. 64, No. 4, p. 525-531. 8. Grzejda R.: New method of modelling nonlinear multi-bolted systems. In: Advances in Mechanics: Theoretical, Computational and Interdisciplinary Issues, Proc. of the 3rd Polish Congress of Mechanics (PCM) and 21st International Conference on Computer Methods in Mechanics (CMM), Leiden: CRC Press/Balkema, 2016, p. 213-216. 9. Ju S.-H., Fan C.-Y., Wu G.H.: Three-dimensional finite elements of steel bolted connections. Engineering Structures 2004, Vol. 26, No. 3, p. 403-413. 10. Kim T.S., Kuwamura H.: Finite element modeling of bolted connections in thin-walled stainless steel plates under static shear. Thin-Walled Structures 2007, Vol. 45, No. 4, p. 407-421. 11. Kozłowski A., Pisarek Z., Wierzbicki S.: Projektowanie zakładkowych połączeń śrubowych według PN-EN 1993-1-1 i PN-EN 1993-1-8. Inżynieria i Budownictwo 2008, nr 9, s. 496-500. 12. Može P., Beg D.: A complete study of bearing stress in single bolt connections. Journal of Constructional Steel Research 2014, Vol. 95, p. 126-140. 13. Naruse T., Kawasaki T., Hattori T.: Simple modelling and strength evaluation methods for bolt joints using shell elements and beam elements (1st Report, Modelling method). Journal of Computational Science and Technology 2009, Vol. 3, No. 1, p. 22-33. 14. Nycz D.B.: Modelowanie końcówek odcinka bariery SP-05/2 do zastosowania w symulacji testów zderzeniowych. Modelowanie Inżynierskie 2016, nr 60, s. 44-51. 15. Nycz D.B.: Modelowanie złączy śrubowych segmentów prowadnicy typu B bariery drogowej SP-05/2. Modelowanie Inżynierskie 2016, nr 58, s. 105-112. 16. Palenica P., Powałka B., Grzejda R.: Assessment of modal parameters of a building structure model. Springer Proceedings in Mathematics & Statistics 2016, Vol. 181, p. 319-325. 17. PN-EN 1993-1-1:2006. Eurokod 3: Projektowanie konstrukcji stalowych, Część 1-1: Reguły ogólne i reguły dla budynków. 18. PN-EN 1993-1-8:2006. Eurokod 3: Projektowanie konstrukcji stalowych, Część 1-8: Projektowanie węzłów. 19. Puchała K., Szymczyk E., Jachimowicz J.: FEM design of composite metal joint for bearing failure analysis. Przegląd Mechaniczny 2015, nr 2, s. 33-41. 20. Raju K.P., Bodjona K., Lim G.-H., Lessard L.: Improving load sharing in hybrid boned/bolted composite joints using an interference-fit bolt. Composite Structures 2016, Vol. 149, p. 329-338. 21. Reid J.D., Hiser N.R.: Detailed modeling of bolted joints with slippage. Finite Elements in Analysis and Design 2005, Vol. 41, No. 6, p. 547-562. 22. Salih E.L., Gardner L., Nethercot D.A.: Numerical investigation of net section failure in stainless steel bolted connections. Journal of Constructional Steel Research 2010, Vol. 66, No. 12, p. 1455-1466. 27
FE-MODELLING OF A BOLTED LAP CONNECTION USING A SIMPLIFIED BOLT MODEL 23. Salih E.L., Gardner L., Nethercot D.A.: Numerical study of stainless steel gusset plate connections. Engineering Structures 2013, Vol. 49, p. 448-464. 24. Tajeuna T.A.D., Légeron F., Labossière P., Demers M., Langlois S.: Effect of geometrical parameters of alumi- composite joint num-to-steel bolted connections. Engineering Structures 2015, Vol. 102, p. 344-357. 25. Wang Z., Zhou S., Zhang J., Wu X., Zhou L.: Progressive failure analysis of bolted single-lap based on extended finite element method. Materials & Design 2012, Vol. 37, p. 582-588. Artykuł dostępny na podstawie licencji Creative Commons Uznanie autorstwa 3.0 Polska. http://creativecommons.org/licenses/by/3.0/pl 28