Kataog słupów rurowych da napowietrznych inii eektroenergetycznych 0kV Tubuar poes cataogue for overhead power ines 0kV 03.
Kataog słupów rurowych da napowietrznych inii eektroenergetycznych 0kV Tubuar poes cataogue for overhead eectrica power ines of 0kV Spis treści / Contents Opis techniczny 4-6 SŁUPY LN JEDNOTOROWYCH SER EWN / NGLE CRCUT POLES EWN SERES Słup serii EWN P / Poe EWN P series 8 Słup serii EWN M / Poe EWN M series 9 Słup serii EWN M4 / Poe EWN M4 series 0 Słup serii EWN M6 / Poe EWN M6 series Słup serii EWN M9 / Poe EWN M9 series Słup serii EWN K / Poe EWN K series 3 Słup serii EWN KK / Poe EWN KK series 4 SŁUPY LN DWUTOROWYCH SER EWND / DOUBLE CRCUT POLES EWND SERES Słup serii EWND P / Poe EWND P series 5 Słup serii EWND M / Poe EWND M series 6 Słup serii EWND M4 / Poe EWND M4 series 7 Słup serii EWND M6 / Poe EWND M6 series 8 Słup serii EWND M9 / Poe EWND M9 series 9 Słup serii EWND K / Poe EWND K series 0 Słup serii EWND KK / Poe EWND KK series SŁUPY LN JEDNOTOROWYCH W UKŁADZE PONOWYM SER EWN L / NGLE CRCUT POLES VERTCAL ARRANGEMENT EWN L SERES Słup serii EWN PL / Poe EWN PL series Słup serii EWN ML / Poe EWN ML series 3 Słup serii EWN ML4 / Poe EWN ML4 series 4 Słup serii EWN ML6 / Poe EWN ML6 series 5 Słup serii EWN ML9 / Poe EWN ML9 series 6 Słup serii EWN KL / Poe EWN KL series 7 Słup serii EWN KKL / Poe EWN KKL series 8 SŁUPY LN DWUTOROWYCH W UKŁADZE PONOWYM SER EWND L / DOUBLE CRCUTS POLES VERTCAL ARRANGEMENT EWND L SERES Słup serii EWND PL / Poe EWND PL series 9 Słup serii EWND ML / Poe EWND ML series 30 Słup serii EWND ML4 / Poe EWND ML4 series 3 Słup serii EWND ML6 / Poe EWND ML6 series 3 Słup serii EWND ML9 / Poe EWND ML9 series 33 Słup serii EWND KL / Poe EWND KL series 34 Słup serii EWND KKL / Poe EWND KKL series 35 Rysunki detai / Detais 36-43
Kataog typowych rozwiązań słup rurowych, da eektroenergetycznych inii napowietrznych o napięciu 0kV Szanowni Państwo, Firma Emonter Oświetenie istnieje od ponad 0 at produkując wysokiej jakości staowe konstrukcje wsporcze da oświetenia. Ciągły rozwój firmy zaowocował rozpoczęciem produkcji słupów da potrzeb napowietrznych inii eektroenergetycznych średniego i wysokiego napięcia. Z wieką przyjemnością oddajemy w Państwa ręce, nowy kataog słupów rurowych serii EWN da napowietrznych inii eektroenergetycznych o napięciu 0kV, zaprojektowanych przez zespół pracowników firmy Emonter Oświetenie.. Podstawa opracowania: W opracowaniu niniejszych rozwiązań słupów rurowych zastosowane zostały następujące normy: PN-EN 5034- Eektroenergetyczne inie napowietrzne prądu przemiennego powyżej 45kV. Część : Wymagania ogóne. Specyfikacje wspóne. PN-EN 5034-3- Eektroenergetyczne inie napowietrzne prądu przemiennego powyżej 45kV. Część 3: Zbiór normatywnych warunków krajowych. Narodowe warunki krajowe Poski. PN-EN 090- + A 0 Wykonanie konstrukcji staowych i auminiowych -- Część : Zasady oceny zgodności eementów konstrukcyjnych. Przedstawione w kataogu rozwiązania są rozwiązaniami standardowymi da słupów EWN. Na każdej karcie kataogowej słupa, znajdują się podstawowe informacje dotyczące słupów, takie jak: wysokość słupa oraz jego podwyższenia, średnice dona i górną jak również przybiżoną ich wagę i powierzchnie maowania. Firma Emonter Oświetenie zastrzega sobie prawo zmiany w/w danych ze wzgędu na uwarunkowania technoogiczne oraz indywiduane dodatkowe wymagania kienta. Wszystkie konstrukcje produkowane przez firmę Emonter Oświetenie są znakowane znakiem CE na zgodność z PN-EN 090- +A 0. W poniższym opracowaniu znajdziecie Państwo słupy da jednotorowych oraz dwutorowych napowietrznych inii eektroenergetycznych o napięciu 0kV o następujących układach inii: EWN słupy jednotorowe w układzie trójkąta EWND słupy dwutorowe w układzie beczkowym z dwoma przewodami mi EWN L słupy jednotorowe w układzie pionowym eśne EWND L słupy dwutorowe w układzie pionowym eśne W zaeżności od zastosowania w inii poszczegónych słupów, kataog zawiera następujące typy słupów: P słupy przeotowe o kącie załomu inii od 80 do 78 M słupy mocne o kącie załomu inii od 80 do 60 M4 słupy mocne o kącie załomu inii od 60 do 40 M6 słupy mocne o kącie załomu inii od 40 do 0 M9 słupy mocne o kącie załomu inii od 0 do 90 K słupy mocne, krańcowe np. da podejścia inii do stacji GPZ KK słupy mocne, kabowe - przystosowane do zajścia z inii napowietrznej na inia kabową. Słupy kabowe wyposażane są w dodatkowe eementy konstrukcyjne, w zaeżności od indywiduanych parametrów inii. Poszczegóne eementy wyposażenia zostały przedstawione na ostatnich stronach kataogu. 3. Strefy kimatyczne Słupy zostały zaprojektowane zgodnie z poniższymi strefami kimatycznymi: strefa wiatrowa W strefa obciążenia obodzeniem A cataogue for typica tubuar soutions for overhead eectrica power ines of 0kV votage Dear customers, Emonter Lighting Company has been present for more than 0 years on the market, producing top quaity stee constructions that support ighting. A constant deveopment of the company resuted in the poes production for the needs of the overhead eectrica power medium and high votage ines. We are peased to introduce you this new cataogue containing tubuar poes from EWN and EWND series that have been designed for overhead eectrica power ines of 0kV votage by a team of engineers from the Emonter Lighting company.. The base of eaboration: We appied foowing standards, as far as the eaboration of the present soutions for tubuar poes is concerned. PN-EN 5034-,,Overhead eectrica power ines exceeding AC 45kV. Part Genera requirements. Common specifications. PN-EN 5034-3- Overhead eectrica power ines exceeding AC 45kV. Part 3: set of nationa normative conditions. Normative Poish nationa conditions. PN-EN 090- +A 0 Execution of stee structures and auminium structures. Requirements for conformity assessment of structura components. The in the cataogue depicted soutions are standard soutions for the EWN and EWD poes. ndividua cataogue cards contain basic pieces of information about particuar type of a poe, such as: its height, the height of its increase, bottom diameter of the poe, as we as the weight and the painting surface. Emonter Lighting company reserves the right to make changes concerning the above mentioned data on the account of the technoogica conditions and individua/ additiona needs of the cient. A constructions manufactured by Emonter Lighting are CE marked for compiance with PN-EN 090- +A 0.. Assortment be circuit ines of overhead eectrica power ines of the 0kV votage. EWN singe circuit poes in the trianguar shape EWND doube circuit poes, barre-shaped with two protection s EWN L singe circuit poes vertica arrangement of forest EWND L doube circuits poes vertica arrangement of forest Depending on the appication of individua poes in the ine, the cataogue contains foowing types of poes: P suspension poe with the bend ange ine from 80 to 78 M tension poe with the bend ange ine from 80 to 60 M4 tension poe with the bend ange ine from 60 to 40 M6 tension poe with the bend ine ange from 40 to 0 M9 tension poe with the bend ine ange from 0 to 90 K dead end (termina e.g. for reaching the ine with the substation KK dead end (cabe poe adjusted to the descent from overhead to the cabe ine. Cabe poes are equipped with additiona, constructiona eements, depending on individua ine parameters. ndividua equipment eements are presented in the ast pages of the cataogue. 3. Cimatic zone Poes have been designed in accordance with the cimatic spheres beow: Wind zone W cing oad zone 4. Przewody robocze i odgromowe a Na słupach serii przewidziano zastosowanie przewodów roboczych: da inii jednotorowej x 3 x AFL-6 40mm da inii dwutorowej x 3 x AFL-6 40mm Maksymany naciąg przewodów roboczych w temperaturze +0 C da słupów jednotorowych EWN 8kN da słupów dwutorowych EWND 8kN da słupów jednotorowych EWN L 3,5kN da słupów dwutorowych EWND L 3,5kN Maksymane naprężenie przewodów roboczych w temperaturze +0 C da słupów jednotorowych EWN 65MPa da słupów dwutorowych EWND 65MPa da słupów jednotorowych EWN L 50MPa da słupów dwutorowych EWND L 50MPa b Na słupach przewidziano zastosowanie przewodów ch: da inii jednotorowej EWN x AFL-.7 70mm da inii dwutorowej EWND x AFL-.7 70mm da inii jednotorowej EWN L x AFL-.7 70mm da inii dwutorowej EWND L x AFL-.7 50mm Maksymany naciąg przewodów ch w temperaturze +0 C da słupów jednotorowych EWN 0kN da słupów dwutorowych EWND 8kN da słupów jednotorowych EWN L 7kN da słupów dwutorowych EWND L 7kN Maksymane naprężenie przewodów ch w temperaturze +0 C da słupów jednotorowych EWN 00MPa da słupów dwutorowych EWND 80MPa da słupów jednotorowych EWN L 7MPa da słupów dwutorowych EWND L 93MPa 5. Łańcuchy izoacyjne Do zawieszenia przewodów roboczych w słupach zastoso- 4 The underying eaboration presents poes for singe and douwano łańcuchy izoatorowe kompozytowe oraz porceano- that have foowing specifications: 5. Asortyment we o następujących typach: ŁP, ŁP łańcuchy do zawieszenia przewodów roboczych na słupach przeotowych o długości łańcuchów od,5m do m i wadze do 00kg ŁO, ŁO łańcuchy do zawieszenia przewodów roboczych na słupach mocnych, krańcowych, kabowych, odporowo- -narożnych o długości łańcuchów,4m do,8m i wadze do 00kg ŁPm łańcuchy przeotowe do podwieszenie mostków prądowych górnej fazy na słupach jednotorowych 6. Długości przęseł Da poszczegónych słupów zostały przyjęte następujące długości przęseł: a Da słupów EWN przyjęto: przęsło i wiatrowe przęsło ciężarowe 400m przęsło gabarytowe 370m b Da słupów EWND przyjęto: przęsło i wiatrowe przęsło ciężarowe 400m przęsło gabarytowe 370m c Da słupów EWN L przyjęto: przęsło i wiatrowe 50 m przęsło ciężarowe 30 m przęsło gabarytowe 90 m d Da słupów EWND L przyjęto: przęsło i wiatrowe 50 m przęsło ciężarowe 30 m przęsło gabarytowe 90 m 4. Working conductors and ightning protection s a There has been foowing appication for working conductors anticipated: For singe circuit ine x 3 x AFL-6 40mm For doube circuit ine x 3 x AFL-6 40mm Maxima tension of working conductors in the +0 C temperature For singe circuit posts EWN 8kN For doube circuit posts EWND 8kN For singe circuit posts EWN L 3,5kN For doube circuits posts EWND L 3,5kN Maxima tension of working conductors in the +0 C temperature For singe circuit posts EWN 65MPa For doube circuit posts EWND 65MPa For singe circuit posts EWN L 50MPa For doube circuits posts EWND L 50MPa b Lightning protection s can be found on the foowing poes: for singe circuit ine EWN x AFL-.7 70mm for doube circuits ine EWND x AFL-.7 70mm for singe circuit ine EWN L x AFL-.7 70mm for doube circuits ine EWND L x AFL-.7 50mm Maxima tension of the ightning protection s in the +0 C temperature. For singe circuit posts EWN 0kN For doube circuit posts EWND 8kN For singe circuit posts EWN L 7kN For doube circuits posts EWND L 7kN Maxima tension of the ightning protection s in the +0 C temperature For singe circuit posts EWN 00MPa For doube circuit posts EWND 80MPa For singe circuit posts EWN L 7MPa For doube circuits posts EWND L 93MPa 5. nsuator strings To pace working conductors on the poes we used two types of strings: composite insuator and porceain insuator ŁP, ŁP strings for pacing the working conductor on the overhead poes strings ength: from,5m to m,weight up to 00kg ŁO, ŁO strings for pacing the working conductor on the suspension, dead end (termina, cabe poes with the string ength of.4m to.8m and the weight up to 00kg. ŁPm trough insuator string for suspension the current bridges of upper phase on singe tension poe 6. Span engths There have been foowing engths for individua poes accepted: a For EWN poes: nomina and wind overa 400m oad 370m b For EWND poes: nomina and wind overa 400m oad - 370m c For EWN L poes: nomina and wind 50 m overa 30 m oad 90 m d For EWND L poes: nomina and wind 50 m overa 30 m oad 90 m
7. nformacje uzupełniające 7. Supementary information Wszystkie wymiary podane na rysunkach słupów, są wymiarami orientacyjnymi i mogą nieznacznie różnić się od podanych na rysunkach. Słupy mogą być dodatkowo wyposażone w system komunikacji i asekuracji pionowej i poziomej dowonego producenta akceptowanego przez zamawiającego. Standardowo system komunikacji i asekuracji rozpoczyna się od wysokości 3m, jednakże na życzenie kienta system może zaczynać się na niższej wysokości. Konieczne jest jednak w takim przypadku zastosowanie specjanej osłony uniemożiwiającej dostęp do systemu osobom nieupoważnionym. Słupy są przystosowane do przymocowania do fundamentu za pomocą kotew. Zestawy kotwiące są integraną częścią słupa i są dostarczane przez firmę Emonter Oświetenie. Słupy można wyposażać w dodatkowe eementy takie jak np.: wieszak zapasu da przewodu odgromowego skrzynki łączeniowe uchwyty do mocowania tabiczek ostrzegawczych, fazowych, numeracyjnych itp. dodatkowych eementów umożiwiających montaż przewodów np. roek do naciągów Wszystkie dodatkowe eementy oraz ich umiejscowienie na słupie jak również ich wymiary naeży uzgodnić przed rozpoczęciem produkcji słupów. Wszystkie słupy są cynkowane ogniowo zgodnie z normą PN EN SO 46. Na życzenie kienta słupy mogą być maowane na koory zgodnie z paetą RAL. Na życzenie kienta producent słupów Emonter Oświetenie, może zapewnić obecność swojego pracownika na czas montażu słupów, jak również wypożyczyć narzędzie do scaania poszczegónych sekcji słupów. W przypadku chęci zastosowania słupów z poniższego kataogu w innych warunkach kimatycznych ub da innych długości przęseł jak również typów przewodów, prosimy o kontakt z firmą Emonter Oświetenie w ceu zweryfikowania poprawności zastosowania konstrukcji da innych warunków pracy. 8. Zaety słupów rurowych Appication of poes in accordance with the most recent 6 european standards = meeting the standard PN-EN 5034-7 Stosowanie słupów zgodnych z najnowszymi normami europejskimi = spełnienie wymogów normy PN-EN 5034-3- Mniejsze wykorzystanie terenu pod słupami = mniejsze koszty wykupu miejsca pod słupem Preferencje społeczne = szybsze uzyskanie zgód właściciei nieruchomości do postawienia słupa Większe możiwości projektowe = możiwość dopasowania gabarytów słupów do możiwości terenowych Większa niezawodność w ekstremanych warunkach = mniejsza awaryjność inii Unikanie kradzieży eementów słupów = mniejsze koszty ekspoatacji inii Możiwość zastosowania różnych systemów asekuracji do pracy na wysokości = bezpieczeństwo pracy monterów Większa eastyczność konstrukcji = dłuższa żywotność Zdecydowanie mniejsza waga w porównaniu ze słupami wirowanymi (betonowymi = mniejsze koszty usług dźwigowych Szybszy montaż słupa = krótszy czas montażu (słup rurowy dzień; słup kratowy 4-5 dni = mniejsze koszty montażu 9. Prawa autorskie Firma Emonter Oświetenie zastrzega sobie prawo do wprowadzania zmian w rozwiązaniach technicznych zamieszczonych w kataogu słupów. Wszekie prawa autorskie do zaproponowanych rozwiązań są zastrzeżone da firmy Emonter Oświetenie. Jakiekowiek powieanie, udostępnianie osobom trzecim w jakiejkowiek formie oraz reprodukowanie bez zgody firmy Emonter Oświetenie jest zabronione. A measurements that have been provided in the cataogue are given ony approximatey and may sighty differ from those presented in the pictures. Poes can be additionay equipped with a communication system, as we as vertica and horizonta precautionary measures from any producer and accepted by the customer. As far as the standards are concerned, the communication and precautionary measures system begins at the height of 3m, however we can adjust the height to the cient s request. n such circumstances we need to use a specia protection that wi prevent unauthorized peope from entering. Poes are fixed to the foundation by anchor bots. Sets for setting the anchor bots are an integra part of the poe and are deivered by the Emonter Lighting Company. Poes can be equipped with additiona eements, such as: refi hanger for protection wiring compartment handes for fixing warning, chase, number tabes etc. additiona eements that wi enabe the instaation, for exampe tension ros A additiona eements, their setting on the poe, as we as their measurements have to be agreed on before starting the production. A poes are hot-deep gavanized according to PN EN SO 46 standard. Poes can be painted using coors in accordance with the RAL paette upon customer s request. Upon customer s request, the Emonter Lighting producer may aso guarantee the presence of its empoyee during the instaation time, as we as end a particuar too which wi serve as a considerabe hep in the process of bending individua poe sections. f you are interested in appying any poe from this cataogue in another cimate spheres or for another engths or types, pease do not hesitate to contact us. Our experts wi verify whether the construction is appropriate to be used in other conditions. 8. Tubuar poes and their advantages 3- requirements. Using a reduced area under the poe = ower costs of buy the area under the poe Socia preferences = getting a faster consent from the area owner More expanded project possibiities = a possibiity to adjust the dimension to the rea and possibiities Greater reiabiity in extreme conditions = ess frequent ine faiures Avoidance of steaing poe eements= ower costs of the ine expoitation A possibiity to use various precautionary measure systems for works at heights= assember work safety Greater construction fexibiity = onger ife Distinctive ower weight in comparison with the spinning poes (concrete = ower costs of the ift services Faster poe instaation = shorter time of instaation (tubuar poe day; attice poe 4-5 days = ower instaation costs 9. Copyrights Emonter Lighting company reserves the right to make changes in the technica soutions of the poes that have been featured in the cataogue. A copyrights for suggested soutions are reserved for the Emonter Lightning company. Copying or sharing with the third party in any form, as we as the reproduction without the Emonter Lightning company permission is forbidden.
8 7 8 9 Słup jednotorowy serii EWN P singe singe-circuit post post seria EWN P a a series series of of tubuar poes 0 kv Słup Słup jednotorowy serii serii EWN EWN M M singe-circuit circuit post post seria seria EWN EWN M M Seria słupów rurowych 0 0 kv kv a series a series of of tubuar poes poes 0 0 kv kv parametry techniczne / technica technica parameters parameters parametry techniczne // technica parameters Zewnętrzna średnica Powierzchnia Surface maowania paint słupa h H Surface (m paint ( m ( m h (m H (m (m EWN P - 5 0,7 40 53 500 EWN P - 5 0,7 40 53 500 EWN P 7,7 70 64 900 EWN P EWN P +,5 7 9,5,7 5, 70 70 64 7 3700 900 EWN EWN P +,5 P +5 9,5 5, 7,7 70 50 7 8 4340 3700 EWN EWN P +5 P +0 7 7,7 3,7 50 370 00 8 6050 4340 EWN P +0 7 3,7 370 00 6050 Strefa wiatrowa / / wind wind zone zone Strefa sadziowa / / icing icing zone zone S 3 x AFL- 6 40 mm 3 x AFL-6 40mm / ightning x AFL -,7 70mm / ighting x AFL-,7 70mm 30 gabarytowe / overa 370 gabarytowe / overa ciężarowe / oad Kąt załowy ciężarowe inii / / bend oad ange 370m 400 80 o - 78 400m o Kąt załowy inii / bend ange 80-78 Zewnętrzna Typ Type of Base pate Surface hh (m H H (m (m ( m ( m EWN EWN M M - - 3 3 0,8 0,8 480 480 68 68 5050 EWN EWN M M 5 5,8,8 570 570 74 74 5700 EWN M M +,5 +,5 7,5 7,55,35,3 660 660 99 99 700 EWN M M +5 +5 0 0 7,8 7,8 670 670 8750 EWN EWN M M +0 +0 5 5 3,8 3,8 890 890 4 4 350 S 3 x AFL- AFL-6 6 40mm 40 mm / ighting / ightning x AFL-,7 AFL -,770mm 70mm 30 gabarytowe / overa / overa 370m 370 ciężarowe / oad / oad 400m Kąt załowy inii / bend / bend ange ange 80 o - -60 60 o
0 9 0 Słup Słup jednotorowy serii serii EWN EWN M4 M4 singe-circuit circuit post post seria seria EWN EWN M4 M4 Seria słupów rurowych 0 0 kv kv a series a series of of tubuar poes poes 0 0 kv kv Słup Słup jednotorowy serii serii EWN EWN M6 M6 singe-circuit circuit post post seria seria EWN EWN M6 M6 kv a a series of of tubuar poes 0 kv kv parametry techniczne // technica parameters Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWN M4 M4 - - 3 3 0,8 0,8 480 480 7 5090 EWN M4 M4 5 5,8,8 570 570 77 5740 EWN M4 +,5 7,5 7,5 5,3 5,3 660 660 0 740 EWN M4 M4 +5 +5 0 0 7,8 7,8 670 670 4 8790 EWN M4 M4 +0 +0 5 5 3,8 3,8 890 890 45 390 S 3 x AFL-6 AFL- 6 40mm 40 mm / ighting / ightning x x AFL-,7 AFL -,7 70mm 70mm 30 gabarytowe gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange 60 o - 40 - o Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWN M6 M6 - - 3 3 0,8 0,8 460 460 74 500 EWN M6 M6 5 5,8,8 580 580 84 6400 EWN M6 +,5 7,5 7,5 5,3 5,3 640 640 99 860 EWN M6 +5 +5 0 0 7,8 7,8 70 70 4 9600 EWN M6 M6 +0 5 5 3,8 3,8 980 980 46 700 S 3 x AFL-6 AFL- 6 40mm 40 mm / ighting / ightning x x AFL-,7 AFL -,7 70mm 70mm 30 gabarytowe gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange 40 o - 0 - o
3 Słup Słup jednotorowy serii serii EWN EWN M9 M9 singe-circuit circuit post post seria seria EWN EWN M9 M9 Seria słupów rurowych 0 0 kv kv a series a series of of tubuar poes poes 0 0 kv kv Słup Słup jednotorowy serii serii EWN EWN K K singe-circuit circuit post post seria seria EWN EWN K K Seria Seria słupów rurowych 0 0 kv kv a series a series of tubuar of tubuar poes poes 0 0 kv kv parametry techniczne // technica parameters parametry techniczne / / technica parameters Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWN M9 M9 - - 3 3 0,8 0,8 640 640 78 6800 EWN M9 M9 5 5,8,8 70 70 9 7900 EWN M9 +,5 7,5 7,5 5,3 5,3 760 760 07 9350 EWN M9 M9 +5 +5 0 0 7,8 7,8 850 850 9 00 EWN M9 M9 +0 +0 5 5 3,8 3,8 070 070 65 4800 S 3 x AFL-6 AFL- 6 40mm 40 mm / ighting / ightning x x AFL-,7 AFL -.7 70mm 70mm 30 gabarytowe gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange 0 - o 90-90 o Zewnętrzna średnica Powierzchnia Surface paint h h (m H H (m (m (m ( m ( m EWN EWN K -K - 3 30,8 0,8 460 460 76 76 560 560 EWN EWN K K 5 5,8,8 580 580 90 90 650 650 EWN EWN K +,5 K +,5 7,5 7,5 5,3 5,3 640 640 05 05 80 80 EWN EWN K +5 K +5 0 07,8 7,8 70 70 0 0 9660 9660 EWN EWN K +0 K +0 5 53,8 3,8 980 980 5 5 760 760 Strefa wiatrowa/ wind zone Strefa sadziowa/ icing zone S Przewody robocze/ working conductor 3 x 3 AFLx AFL-6 6 40 40mm mm / / ightning ighting x x AFL AFL-,7 -,7 70mm 70mm / / nomina nomina gabarytowe/ / overa 370m ciężarowe/ / oad 400m Kąt Kąt załowy inii/ / bend ange krańcowy
4 3 4 5 Słup Słup jednotorowy serii serii EWN EWN KK KK singe-circuit circuit post post seria seria EWN EWN KK KK Seria słupów rurowych 0 0 kv kv a series a series of of tubuar poes poes 0 0 kv kv Słup Słup dwutorowy serii serii EWND P P doube doube circuits circuit post post seria seria EWND EWND P P kv a a series of of tubuar poes 0 kv kv parametry techniczne // technica parameters Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWN KK KK - - 3 3 0,8 0,8 460 460 76 5590 EWN KK KK 5 5,8,8 580 580 90 6840 EWN KK KK +,5 7,5 7,5 5,3 5,3 640 640 05 8550 EWN KK KK +5 +5 0 0 7,8 7,8 70 70 0 9990 EWN KK KK +0 +0 5 5 3,8 3,8 980 980 5 3090 Strefa wiatrowa/ wind zone S 3 x AFL-6 AFL- 6 40mm 40 mm / ighting / ightning x x AFL-,7 AFL -,7 70mm 70mm 30 gabarytowe gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange kabowy Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWND P P - - 5 5 4 4 380 380 8 4900 EWND P P 7 7 6 6 480 480 90 5500 EWND P +,5 9,5 9,5 8,5 8,5 540 540 0 6000 EWND P +5 +5 3 3 540 540 9 7650 EWND P P +0 7 7 36 36 830 830 49 9800 S x 3 x AFL-6 AFL- 6 40mm 40 mm / ighting / ightning x x x x AFL-,7 AFL -.7 70mm 70mm 30 gabarytowe gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange 80 80 - o 78 - o
6 5 6 7 Słup dwutorowy serii EWND M doube circuits post seria EWND M kv Słup dwutorowy serii EWND M4 doube circuits post seria EWND M4 parametry techniczne // technica parameters Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWND M M - - EWND M M EWND M +,5 EWND M +5 +5 EWND M M +0 3 3 5 5 7,5 7,5 0 0 5 5 3,5 3,5 5,5 5,5 8 8 30,5 30,5 35,5 35,5 80 80 900 900 070 070 80 80 50 50 0 4 30 50 0 9300 040 00 4800 0550 S x 3 x AFL-6 AFL- 640mm mm / ighting / ightning x x x AFL-,7 -.7 70mm 70mm 30 gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange 80 - o 60 - o Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWND M4 M4 - - 3 3 3,5 3,5 80 80 05 9360 EWND M4 M4 5 5 5,5 5,5 900 900 8 0480 EWND M4 +,5 7,5 7,5 8 8 070 070 34 60 EWND M4 +5 +5 0 0 30,5 30,5 80 80 54 4860 EWND M4 M4 +0 5 5 35,5 35,5 50 50 06 060 S x 3 x AFL-6 AFL- 6 40mm 40 mm / ighting / ightning x x x x AFL-,7 AFL -.7 70mm 70mm 30 gabarytowe gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange 60 60- o 40 - o
8 7 8 9 Słup dwutorowy serii EWND M6 doube circuits post seria EWND M6 kv Słup Słup dwutorowy serii serii EWND M9 M9 doube doube circuits circuit post post seria seria EWND EWND M9 M9 kv a a series of of tubuar poes poes 0 0 kv kv parametry techniczne // technica parameters parametry techniczne / technica / technica parameters Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWND M6 M6- EWND M6 M6 EWND M6+,5 EWND M6+5 EWND M6 M6+0 3 3 5 5 7,5 7,5 0 0 5 5 3,5 3,5 5,5 5,5 8 8 30,5 30,5 35,5 35,5 900 900 930 930 070 070 80 80 50 50 0 37 68 04 0000 050 650 6350 500 S x 3 x AFL-6 AFL- 640mm mm / ighting / ightning x x x AFL-,7 -.7 70mm 70mm 30 gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange 40 - o 0 - o Zewnętrzna średnica Powierzchnia Surface paint h h (m H H (m (m (m ( m ( m EWND EWND M9 - M9-3 3 3,5 3,5 0 0 4 4 850 850 EWND EWND M9 M9 5 5 5,5 5,5 0 0 46 46 3600 3600 EWND EWND M9 +,5 M9 +,5 7,5 7,5 8 8 0 0 60 60 5950 5950 EWND EWND M9 +5 M9 +5 0 0 30,5 30,5 50 50 63 63 000 000 EWND EWND M9 +0 M9 +0 5 5 35,5 35,5 340 340 9 9 650 550 S x 3 x 3 AFLx AFL-6 6 40 40mm mm / / ightning ighting x x AFL x AFL-,7 -.7 70mm 70mm / / nomina nomina gabarytowe gabarytowe // overa 370m ciężarowe / / oad 400m Kąt Kąt załowy załowy inii inii / / bend ange 0 0 o - 90-90 o
0 9 0 Słup dwutorowe dwutorowy serii EWND K doube circuits post seria EWND K kv Słup dwutorowy serii EWND KK doube circuits post seria EWND KK a series of of tubuar poes 0 kv kv parametry techniczne // technica parameters Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWND K K - - EWND K EWND K +,5 EWND K +5 +5 EWND K +0 3 3 5 5 7,5 7,5 0 0 5 5 3,5 3,5 5,5 5,5 8 8 30,5 30,5 35,5 35,5 900 900 930 930 070 070 80 80 50 50 8 30 45 76 0080 30 730 6430 580 S x 3 x AFL-6 AFL- 640mm mm / ighting / ightning x x x AFL-,7 -.7 70mm 70mm 30 gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange końcowy Zewnętrzna Typ Type of Base pate h (m HH (m (m ( m ( m EWND KK KK - - 3 3 3,5 3,5 900 900 8 0490 EWND KK KK 5 5 5,5 5,5 930 930 30 540 EWND KK KK +,5 7,5 7,5 8 8 070 070 45 340 EWND KK +5 +5 0 0 30,5 30,5 80 80 76 6840 EWND KK KK +0 5 5 35,5 35,5 50 50 990 S x 3 x AFL-6 AFL- 6 40mm 40 mm / ighting / ightning x x x x AFL-,7 AFL -.7 70mm 70mm 30 gabarytowe gabarytowe / overa / overa 370m370 ciężarowe / oad / oad 400m400 Kąt załowy inii inii / bend / bend ange ange kabowy
0.5.8 3.0 3.5 3.0 3.5 3.0 H h 3 3000 Słup jednotorowy serii EWN PL singe circuit post seria EWN PL Słup jednotorowy serii EWN ML singe circuit post seria EWN ML h (m H (m (m EWN PL 6 4,8 80 5 3470 EWN PL +,5 8,5 7,3 40 58 3900 EWN PL +5 9,8 30 67 450 EWN PL +0 6 34,8 560 9 5640 3 x AFL-6 40mm / ighting x AFL-,7 70mm gabarytowe / overa ciężarowe / oad h (m H (m (m EWN ML 4 5, 540 65 4830 EWN ML +,5 6,5 7,6 580 75 5590 EWN ML +5 9 30, 600 84 690 EWN ML +0 4 35, 790 07 9070 3 x AFL-6 40mm / ighting x AFL-,7 70mm gabarytowe / overa ciężarowe / oad Kąt załowy inii / bend ange 80-78 Kąt załowy inii / bend ange 80-60
4 5 Słup jednotorowy serii EWN ML4 singe circuit post seria EWN ML4 Słup jednotorowy serii EWN ML6 singe circuit post seria EWN ML6 h (m H (m (m EWN ML4 4 5, 540 65 560 EWN ML4 +,5 6,5 7,6 600 80 650 EWN ML4 +5 9 30, 690 9 7530 EWN ML4 +0 4 35, 890 7 0550 3 x AFL-6 40mm / ighting x AFL-,7 70mm gabarytowe / overa ciężarowe / oad h (m H (m (m EWN ML6 4 5, 670 74 6370 EWN ML6 +,5 6,5 7,6 750 85 790 EWN ML6 +5 9 30, 80 96 870 EWN ML6 +0 4 35, 040 4 00 3 x AFL-6 40mm / ighting x AFL-,7 70mm gabarytowe / overa ciężarowe / oad Kąt załowy inii / bend ange 60-40 Kąt załowy inii / bend ange 40-0
6 7 Słup jednotorowy serii EWN ML9 singe circuit post seria EWN ML9 Słup jednotorowy serii EWN KL singe circuit post seria EWN KL h (m H (m (m EWN ML9 4 5, 670 74 770 EWN ML9 +,5 6,5 7,6 80 87 9090 EWN ML9 +5 9 30, 90 0 0640 EWN ML9 +0 4 35, 070 6 430 3 x AFL-6 40mm / ighting x AFL-,7 70mm gabarytowe / overa ciężarowe / oad h (m H (m (m EWN KL 4 5, 560 68 6370 EWN KL +,5 6,5 7,6 750 86 770 EWN KL +5 9 30, 80 97 8630 EWN KL +0 4 35, 890 5 000 3 x AFL-6 40mm / ighting x AFL-,7 70mm gabarytowe / overa ciężarowe / oad Kąt załowy inii / bend ange 0-90 Kąt załowy inii / bend ange krańcowy
0.5 0.5.0 3.0 3.0 3.5 3.0 3.0 3.5 3.0 3.0 H h 8 9 3000 Słup jednotorowy serii EWN KKL singe circuit post seria EWND KKL Słup dwutorowy serii EWND PL doube circuits post seria EWND PL h (m H (m (m EWN KKL 4 5, 560 68 670 EWN KKL +,5 6,5 7,6 750 86 760 EWN KKL +5 9 30, 80 97 8970 EWN KKL +0 4 35, 890 5 340 3 x AFL-6 40mm / ighting x AFL-,7 70mm gabarytowe / overa ciężarowe / oad h (m H (m (m EWND PL 6 5 40 6 560 EWND PL +,5 8,5 7,5 480 70 5950 EWND PL +5 30 560 79 6580 EWND PL +0 6 35 700 04 9090 x 3 x AFL-6 40mm / ighting x x AFL-,7 50mm gabarytowe / overa ciężarowe / oad Kąt załowy inii / bend ange kabowy Kąt załowy inii / bend ange 80-78
30 3 Słup dwutorowy serii EWND ML doube circuits post seria EWND ML Słup dwutorowy serii EWND ML4 doube circuits post seria EWND ML4 h (m H (m (m EWND ML 4 4 600 68 6530 EWND ML +,5 6,5 6,5 60 78 8630 EWND ML +5 9 9 800 90 0030 EWND ML +0 4 34 90 5 3370 x 3 x AFL-6 40mm / ighting x x AFL-,7 50mm gabarytowe / overa ciężarowe / oad h (m H (m (m EWND ML4 4 4 70 73 8840 EWND ML4 +,5 6,5 6,5 850 85 030 EWND ML4 +5 9 9 030 0 40 EWND ML4 +0 4 34 90 3 5500 x 3 x AFL-6 40mm / ighting x x AFL-,7 50mm gabarytowe / overa ciężarowe / oad Kąt załowy inii / bend ange 80-60 Kąt załowy inii / bend ange 60-40
3 33 Słup dwutorowy serii EWND ML6 doube circuits post seria EWND ML6 Słup dwutorowy serii EWND ML9 doube circuits post seria EWND ML9 h (m H (m (m EWND ML6 4 4 840 85 930 EWND ML6 +,5 6,5 6,5 030 98 530 EWND ML6 +5 9 9 0 0 80 EWND ML6 +0 4 34 80 44 930 x 3 x AFL-6 40mm / ighting x x AFL-,7 50mm gabarytowe / overa ciężarowe / oad h (m H (m (m EWND ML9 4 4 50 94 440 EWND ML9 +,5 6,5 6,5 40 09 3000 EWND ML9 +5 9 9 80 5 5830 EWND ML9 +0 4 34 30 53 970 x 3 x AFL-6 40mm / ighting x x AFL-,7 50mm gabarytowe / overa ciężarowe / oad Kąt załowy inii / bend ange 40-0 Kąt załowy inii / bend ange 0-90
34 35 Słup dwutorowy serii EWND KL doube circuits post seria EWND KL Słup dwutorowy serii EWND KKL doube circuits post seria EWND KKL h (m H (m (m EWND KL 4 4 80 83 8990 EWND KL +,5 6,5 6,5 890 94 0830 EWND KL +5 9 9 960 05 90 EWND KL +0 4 34 80 43 8440 x 3 x AFL-6 40mm / ighting x x AFL-,7 50mm gabarytowe / overa ciężarowe / oad h (m H (m (m EWND KKL 4 4 80 83 940 EWND KKL +,5 6,5 6,5 890 94 50 EWND KKL +5 9 9 960 05 60 EWND KKL +0 4 34 80 43 8860 x 3 x AFL-6 40mm / ighting x x AFL-,7 50mm gabarytowe / overa ciężarowe / oad Kąt załowy inii / bend ange krańcowy Kąt załowy inii / bend ange kabowy
36 jednopunktowe dwupunktowe 37 one point system 3 mostek obejściowy two points system opis detai / description detais Mocowanie tabiczek ostrzegawczych / Uziemienie słupa Fixing of a warning pates / Post earthing cabe opis detai / description detais Mocowanie tabic, przewodów, skrzynek Fixing of a pates, s, boxes Przyłączenie uziemienia słupa / connecting points for post earthing cabe Mocowanie tabiczek ostrzegawczych typu A oraz numeracyjno kodowej / Mocowanie i uziemienie icznika zadziałań typu GLX / Mocowanie tabicy oznaczenia faz / 3 Mocowanie przewodu roboczego i odgromowego na porzeczniku /
poprzecznik głowicy kabowej crossarm cabe head SYSTEM ASEKURACJ POZOMEJ horizonta asekuration system SYSTEM ASEKURACJ POZOMEJ horizonta asekuration system poprzecznik głowicy kabowej crossarm cabe head 38 3 4 39 opis detai / description detais Mocowanie przewodu roboczego i odgromowego na słupie Fixing of a working conductor and ightning protection opis detai / description detais System mocowania głowicy kabowej / Mocowanie przewodów do iczników zadziałań Head mounting system cabe / Fixing of operation counters Mocowanie przewodu roboczego i odgromowego na słupie / Poprzecznik głowicy kabowej / cabe head outrigger Prowadzenie przewodu do icznika zadziałań / arrangement of an operation counters grips aong the post
PODEST OBSŁUGOWY maintenance patform ASEKURACJA POZOMA horizonta asecuration system PODEST OBSŁUGOWY 3 maintenance patform 3 PODEST OBSŁUGOWY maintenance patform ASEKURACJA POZOMA horizonta asecuration system PODEST OBSŁUGOWY maintenance patform 3 POPRZECZNK GŁOWCY KABLOWEJ OGRANCZNKA PRZEPĘĆ Cabe head outrigger 3 40 5 4 PODEST OBSŁUGOWY 3 maintenance patform 3 ASEKURACJA POZOMA horizonta asecuration system PODEST OBSŁUGOWY maintenance patform opis detai / description detais System mocowania głowicy kabowej i ogranicznika przepięć na wspónym poprzeczniku Cabe head outrigger and suregar arestere opis detai / description detais Reguowana prowadnica kabi 0kV / Osłona kabi 0kV Guide for 0kV cabe / Cover for 0kV cabe System mocowania głowicy kabowej i ogranicznika przepięć / cabe head outrigger and suregar arestere Przekrój słupa / section of the coumn 3 Przekrój słupa / section of the coumn 3 Prowadnica kaba 0kV / guide for 0kV cabe Osłona zejścia kaba 0kV / cover for 0kV cabe Mocowanie ostrokołu do słupa /
4 8 43 opis detai / description detais Mocowanie wieszaka zapasu OPGW oraz przykład prowadzenia wzdłuż słupa Fixing of an OPGW inventory rack and exampe ducting of OPGW aong the post opis detai / description detais Łączenie sekcji słupa / Montaż zestawu kotwiącego Assembing of poe section / Montage of an anchor bots cage Mocowanie wieszaka zapasu OPGW / Mocowanie mufy łączącej OPGW / Łączenie sekcji słupa / assembing of poe section Montaż zestawu kotwiącego / montage of an anchor bots cage
44