Wyniki pomiarów szybkości korozji ziemnej stali w pobliżu konstrukcji chronionych katodowo

Podobne dokumenty
WYNIKI POMIARÓW SZYBKOŚCI KOROZJI ZIEMNEJ STALI W POBLIŻU KONSTRUKCJI CHRONIONYCH KATODOWO

KOROZYMETRIA REZYSTANCYJNA JAKO DOGODNY SPOSÓB OCENY SKUTECZNOŚCI OCHRONY KATODOWEJ

WPŁYW KOROZJI WŻEROWEJ NA OCENĘ SKUTECZNOŚCI OCHRONY KATODOWEJ METODĄ KOROZYMETRII REZYSTANCYJNEJ

SYSTEM CORRPOL-ER INTERNETOWA BAZA DANYCH REZYSTOMETRYCZNYCH WRAZ Z KALKULATOREM UBYTKÓW KOROZYJNYCH

NIENISZCZĄCE BADANIA ZAGROŻENIA KOROZJĄ ZBROJENIA W KONSTRUKCJACH ŻELBETOWYCH

Akademia Morska w Szczecinie. Wydział Mechaniczny

Formularz recenzji magazynu. Journal of Corporate Responsibility and Leadership Review Form

KOROZYMETRIA JAKO WIARYGODNA TECHNIKA POMIARU SKUTECZNOŚCI OCHRONY KATODOWEJ

WYKAZ PRÓB / SUMMARY OF TESTS. mgr ing. Janusz Bandel

Rozpoznawanie twarzy metodą PCA Michał Bereta 1. Testowanie statystycznej istotności różnic między jakością klasyfikatorów

Has the heat wave frequency or intensity changed in Poland since 1950?

Stara metoda w nowej odsłonie zastosowanie korozymetrii w technologii ochrony katodowej


OCENA PARAMETRÓW POLARYZACJI KATODOWEJ W SPOSÓB INSTRUMENTALNY INSTRUMENTAL ASSESSMENT OF CATHODIC POLARISATION PARAMETERS

EXAMPLES OF CABRI GEOMETRE II APPLICATION IN GEOMETRIC SCIENTIFIC RESEARCH

NAPRĘŻENIA ŚCISKAJĄCE PRZY 10% ODKSZTAŁCENIU WZGLĘDNYM PRÓBEK NORMOWYCH POBRANYCH Z PŁYT EPS O RÓŻNEJ GRUBOŚCI

Machine Learning for Data Science (CS4786) Lecture11. Random Projections & Canonical Correlation Analysis

Krytyczne czynniki sukcesu w zarządzaniu projektami

Cracow University of Economics Poland. Overview. Sources of Real GDP per Capita Growth: Polish Regional-Macroeconomic Dimensions


INSPECTION METHODS FOR QUALITY CONTROL OF FIBRE METAL LAMINATES IN AEROSPACE COMPONENTS

ARNOLD. EDUKACJA KULTURYSTY (POLSKA WERSJA JEZYKOWA) BY DOUGLAS KENT HALL

SPITSBERGEN HORNSUND

OpenPoland.net API Documentation

Proposal of thesis topic for mgr in. (MSE) programme in Telecommunications and Computer Science

Zakopane, plan miasta: Skala ok. 1: = City map (Polish Edition)

ZGŁOSZENIE WSPÓLNEGO POLSKO -. PROJEKTU NA LATA: APPLICATION FOR A JOINT POLISH -... PROJECT FOR THE YEARS:.

Patients price acceptance SELECTED FINDINGS

SSW1.1, HFW Fry #20, Zeno #25 Benchmark: Qtr.1. Fry #65, Zeno #67. like

PARAMETRY TECHNICZNE DEKLAROWANE PRZEZ PRODUCENTA POTWIERDZONE BADANIAMI / RATINGS ASSIGNED BY THE MANUFACTURER AND PROVED BY TESTS

WYŁĄCZNIK CZASOWY OUTDOOR TIMER

Fig 5 Spectrograms of the original signal (top) extracted shaft-related GAD components (middle) and


PROCEEDINGS OF THE INSTITUTE OF VEHICLES 2(106)/2016 (12 pt)

Przegląd współczesnych technik monitorowania skuteczności ochrony katodowej obiektów przemysłowych

NORMALIZACJA TECHNOLOGII OCHRONY KATODOWEJ CZAS NA NOWELIZACJĘ STANDARDISATION OF CATHODIC PROTECTION TECHNOLOGY TIME FOR A REVISION

Szkolenie personelu ochrony katodowej. Sektor: konstrukcje podziemne i zanurzone

Machine Learning for Data Science (CS4786) Lecture 11. Spectral Embedding + Clustering

SPITSBERGEN HORNSUND

POMIARY NATĘŻENIA POLA ELEKTROMAGNETYCZNEGO MAŁYCH CZĘSTOTLIWOŚCI W OBIEKTACH PRZEMYSŁOWYCH

Helena Boguta, klasa 8W, rok szkolny 2018/2019

Jazz EB207S is a slim, compact and outstanding looking SATA to USB 2.0 HDD enclosure. The case is

sorriso Design: Studio 1:1 Jarosław Szymański

RADIO DISTURBANCE Zakłócenia radioelektryczne

INTERNETOWY SYSTEM MONITOROWANIA OCHRONY KATODOWEJ INTERNET CATHODIC PROTECTION MONITORING SYSTEM

Sargent Opens Sonairte Farmers' Market

XV Konferencja POLSKIEGO KOMITETU ELEKTROCHEMICZNEJ OCHRONY PRZED KOROZJĄ Stowarzyszenia Elektryków Polskich Pomiary korozyjne w ochronie

Opis Przedmiotu Zamówienia oraz kryteria oceny ofert. Części nr 10

Degradacja korozyjna rurociągów. Paweł Domżalicki

PORTS AS LOGISTICS CENTERS FOR CONSTRUCTION AND OPERATION OF THE OFFSHORE WIND FARMS - CASE OF SASSNITZ

HAPPY ANIMALS L01 HAPPY ANIMALS L03 HAPPY ANIMALS L05 HAPPY ANIMALS L07

HAPPY ANIMALS L02 HAPPY ANIMALS L04 HAPPY ANIMALS L06 HAPPY ANIMALS L08

SPITSBERGEN HORNSUND

SWPS Uniwersytet Humanistycznospołeczny. Wydział Zamiejscowy we Wrocławiu. Karolina Horodyska

Installation of EuroCert software for qualified electronic signature

ZWROTNICOWY ROZJAZD.

Cracow University of Economics Poland

Knovel Math: Jakość produktu

RADIO DISTURBANCE Zakłócenia radioelektryczne

POLITECHNIKA ŚLĄSKA INSTYTUT AUTOMATYKI ZAKŁAD SYSTEMÓW POMIAROWYCH

ODWIERT GAZOWY SŁUŻĄCY DO PODZIEMNEGO MAGAZYNOWANIA GAZU ZIEMNEGO OCHRONA KATODOWA ODWIERTU

SPITSBERGEN HORNSUND

OCHRONA PRZED KOROZJĄ PRZEMIENNOPRĄDOWĄ STUDIUM PRZYPADKU NA PODSTAWIE DOŚWIADCZEŃ TERENOWYCH

4. EKSPLOATACJA UKŁADU NAPĘD ZWROTNICOWY ROZJAZD. DEFINICJA SIŁ W UKŁADZIE Siła nastawcza Siła trzymania

Tychy, plan miasta: Skala 1: (Polish Edition)

Elektrody symulujące jako narzędzie do badań skuteczności ochrony katodowej stalowych konstrukcji

WENTYLATORY PROMIENIOWE SINGLE-INLET DRUM BĘBNOWE JEDNOSTRUMIENIOWE CENTRIFUGAL FAN

DELTIM Sp. z o.o. S.K.A ul. Rząsawska 30/38; Częstochowa. Bumper bar X-Lander X-Move


Raport bieżący: 44/2018 Data: g. 21:03 Skrócona nazwa emitenta: SERINUS ENERGY plc


oceny skuteczności ochrony katodowej. propozycja metody instrumentalnej

Warsztaty Ocena wiarygodności badania z randomizacją

ZGŁOSZENIE WSPÓLNEGO POLSKO -. PROJEKTU NA LATA: APPLICATION FOR A JOINT POLISH -... PROJECT FOR THE YEARS:.

Rola Polskiego Komitetu Elektrochemicznej Ochrony przed KorozjąSEP w rozwoju technologii ochrony katodowej w Polsce. Wojciech Sokólski SPZP CORRPOL

Wpływ zanieczyszczenia torowiska na drogę hamowania tramwaju

OCHRONA ELEKTROCHEMICZNA CEL, EFEKTY, SKUTKI ZANIEDBAŃ ELECTROCHEMICAL PROTECTION SCOPE, RESULTS, CONSEQUENCES OF NEGLIGENCE

DUAL SIMILARITY OF VOLTAGE TO CURRENT AND CURRENT TO VOLTAGE TRANSFER FUNCTION OF HYBRID ACTIVE TWO- PORTS WITH CONVERSION

OPTYMALIZACJA PUBLICZNEGO TRANSPORTU ZBIOROWEGO W GMINIE ŚRODA WIELKOPOLSKA

Arca. Design: Ronald Straubel


DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE!

DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE!

TECHNICAL CATALOGUE WHITEHEART MALLEABLE CAST IRON FITTINGS EE

HAPPY K04 INSTRUKCJA MONTAŻU ASSEMBLY INSTRUCTIONS DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE! W5 W6 G1 T2 U1 U2 TZ1

Latest Development of Composite Indicators in the Czech Republic

Latent Dirichlet Allocation Models and their Evaluation IT for Practice 2016

Terminarz postępowania rekrutacyjnego na studia I stopnia stacjonarne Deadlines for admission for Bachelor (first-level) full time studies

Praktyczne aspekty wymiarowania belek żelbetowych podwójnie zbrojonych w świetle PN-EN

THE CASE OF ALTERNATING CURRENT IMPACT ON HIGH PRESSURE PIPELINES

ETICS: Few words about the Polish market Dr. Jacek Michalak Stowarzyszenie na Rzecz Systemów Ociepleń (SSO), Warsaw, Poland

NIEROZWIĄZANE PROBLEMY OCHRONY KATODOWEJ UNSOLVED PROBLEMS OF CATHODIC PROTECTION. Streszczenie. Abstract

POLITECHNIKA WARSZAWSKA. Wydział Zarządzania ROZPRAWA DOKTORSKA. mgr Marcin Chrząścik

Weekly report 01/2018

Hard-Margin Support Vector Machines

KOMPUTEROWE PROJEKTOWANIE I OBLICZANIE REZYSTANCJI UZIOMÓW W STREFACH ZAGROŻONYCH WYBUCHEM

SPITSBERGEN HORNSUND

European Crime Prevention Award (ECPA) Annex I - new version 2014

Analiza porównawcza zmian w rozbiorach wody z uwzględnieniem sposobu jej dostarczania do odbiorców

Transkrypt:

JEZMAR JANKOWSKI WOJCIECH SOKÓLSKI SPZP CORRPOL Sp. z o.o. DOI: 10.15199/40.2015.8.3 ochrona przed korozja 8/2015 Prosimy cytować jako: Ochr. Przed Koroz., 2015, 58, 8, (286-291) Please cite as: Ochr. Przed Koroz., 2015, 58, 8, (286-291) DOI: 10.15199/40.2015.8.3 Wyniki pomiarów szybkości korozji ziemnej stali w pobliżu konstrukcji chronionych katodowo Zaprezentowano wybrane wyniki długoterminowych pomiarów szybkości korozji stali w ziemi w pobliżu zakopcowanych zbiorników chronionych katodowo. Pomiary dokonywano metodą korozymetrii rezystancyjnej za pomocą czujników o powierzchni eksponowanej 10 cm 2 posadowionych w gruncie piaszczystym. Mierzono narastające ubytki korozyjne w okresie 3 lat przed zastosowaniem ochrony katodowej zbiorników oraz ok. 4 lat po jej załączeniu zarówno dla stali polaryzowanej katodowo jak i swobodnie korodującej. Zaobserwowano w niektórych przypadkach wyraźne oddziaływanie ochrony katodowej zbiorników na próbki stali swobodnie korodującej skutkujące obniżeniem ich szybkości korozji. Słowa kluczowe: stal, korozja ziemna, pomiary szybkości korozji, czujniki korozymetryczne rezystancyjne, ochrona katodowa Results of corrosion rate measurements for steel in soil in vicinity of cathodically protected structures The paper presents selected results of long-term measurements of the corrosion rate of steel in the ground near the mounded tanks with cathodic protection. Measurements were made using electrical resistance probes with an area of 10 cm 2 exposed in sandy soil. Increasing corrosion losses were measured during the three years prior to the application of cathodic protection of tanks and approx. 4 years after it for both cathodically polarized and freely corroding steel. It has been observed in some cases, a marked influence of cathodic protection of tanks on freely corroding steel samples resulting in reduction in their corrosion rate. Keywords: steel, corrosion in soil, corrosion rate measurements, electrical resistance probes, cathodic protection 1. Wstęp W ostatnich latach do monitorowania szybkości korozji konstrukcji podziemnych, zarówno w celu oceny wielkości ich zagrożenia korozyjnego jak i skuteczności ochrony katodowej, coraz szerzej wykorzystuje się technikę korozymetrii rezystancyjnej. Wskazuje na to rosnąca ilość doniesień w renomowanych czasopismach naukowo technicznych [1 3] oraz publikowane na ten temat opracowania i raporty [4, 5]. Technika ta ma istotne zalety w stosunku do alternatywnie stosowanych kuponów korozyjnych. W przeciwieństwie do nich nie wymaga ona dokonywania odkrywek, oczyszczania i ważenia próbek, ponieważ ubytki korozyjne określane są w sposób elektroniczny z powierzchni ziemi. Stosowane w miejsce kuponów czujniki korozymetryczne (nazywane czujnikami ER) mogą pełnić ponadto funkcję elektrod symulujących umożliwiając dokonywanie innych istotnych w technologii ochrony katodowej pomiarów: potencjału, gęstości prądu (dc i ac) i rezystancji przejścia. W kraju pierwsze prace nad wykorzystaniem korozymetrii rezystancyjnej do monitorowania zagrożenia korozyjnego konstrukcji podziemnych, jak również skuteczności ich ochrony katodowej podjęto w Politechnice Gdańskiej w latach 90. ubiegłego wieku [6 8]. W ciągu ok. 20 lat stosowania ta technika pomiarowa zyskała ugruntowaną pozycję szczególnie w polskim gazownictwie, gdzie uzupełnia z powodzeniem klasyczne pomiary potencjałowe i została ujęta w obowiązujących zaleceniach dot. ochrony przed korozją zewnętrzną stalowych gazociągów lądowych [9, 10]. Więcej informacji praktycznych na temat zastosowań korozymetrii rezystancyjnej w technologii ochrony katodowej można znaleźć w opublikowanych pracach SPZP CORRPOL [11 17]. 1. Introduction The electrical resistance technique is being more extensively applied in recent years for monitoring of the corrosion rate of underground structures for assessment of their corrosion hazard, as well as cathodic protection effectiveness. This is shown by the increasing number of papers in renowned scientific journals [1 3] and published studies and reports on this subject [4, 5]. This technique provides significant advantages in comparison with alternately applied corrosion weight loss coupons. Contrary to them it does not require uncovering, cleaning and weighing of coupons, as corrosion losses are determined electronically from the ground surface. Electrical resistance probes (ER) applied instead of coupons may also fulfil the function of simulating electrodes (corrosion probes) allowing performing of other significant measurements in cathodic protection technology: potential, current density (dc and ac) and spread resistance. In Poland first works on application of electrical resistance technique for monitoring the corrosion hazard of underground structures, as well as effectiveness of their cathodic protection, were undertaken in the Gdańsk University of Technology in the nineties of the previous century [6 8]. During approx. 20 years of application this technique gained an established position especially in the Polish gas industry, where it successfully supplements classical potential measurements and has been inserted in obligatory recommendations concerning external anticorrosion protection of steel land gas pipelines [9, 10]. More practical information on application of the electrical resistance technique in cathodic protection technology can be found in works published by SPZP CORRPOL [11 17]. 286 Ochrona przed Korozją, ISSN 0473-7733, e-issn 2449-9501, vol. 58, nr 8/2015

W niniejszej pracy przedstawiono przykład wykorzystania tej techniki do rozwiązania problemu niewłaściwie zabezpieczonych przed korozją 4 zbiorników na węglowodory zakopcowanych na tacy żelbetowej w jednej z krajowych elektrociepłowni. Ze względów oszczędnościowych dla obiektu tego nie przewidziano podczas projektowania ochrony katodowej. Dodatkowo okazało się, że podczas budowy konstrukcje zbiorników zostały nierozłącznie połączone ze zbrojeniem żelbetu tworząc niebezpieczne makroogniwa korozyjne, w których zbiorniki pełnią rolę anod. W pierwszym etapie badań za pomocą czujników korozymetrycznych zdiagnozowano zagrożenie korozyjne zbiorników, a następnie wykorzystano je do oceny skuteczności działania zaprojektowanej i wykonanej na tej podstawie instalacji ochrony katodowej. 2. Metodyka badań Do badań wykorzystano czujniki korozymetryczne rezystancyjne typu ER-10/1,0-FC produkcji SPZP CORRPOL wyposażone w stalowe elementy pomiarowe o polu powierzchni 10 cm 2 i grubości 1,0 mm. Usytuowanie czujników w stosunku do zbiorników pokazano schematycznie na rys. 1. Obejmuje ono przekrojowo najbardziej charakterystyczne miejsca zagrożeń korozyjnych zbiorników związane z ich lokalizacją w kopcu ziemnym na tacy żelbetowej. Ogółem wytypowano do badań 6 takich miejsc ponumerowanych kolejno od 1 do 6 (połowa w dolnej części zbiorników, połowa w górnej). W każdym z nich umieszczono w gruncie obok siebie po dwa czujniki, z których jeden podłączony elektrycznie do najbliższego zbiornika (oznaczenie Z ) odzwierciedlał lokalne zagrożenie powodowane przez makro ogniwa korozyjne, zaś drugi pozostawał swobodnie korodujący (niepołączony elektrycznie ze zbiornikiem oznaczenie S ) umożliwiając określenie zagrożenia wywołanego przez samo środowisko korozyjne. Do pomiarów rezystometrycznych stosowano miernik MultiCorr MKII produkcji CORROCEAN (Norwegia) oraz przyrząd wg własnego opracowania ATLAS 1001 [18]. Pomiary korozymetryczne prowadzono od września 2007 r. Pomiary ubytków korozyjnych stali przy pomocy zestawu 12 czujników prowadzono początkowo w odstępach 2-tygodniowych. W dalszym okresie, ze względu na obserwowane wolniejsze zmiany szybkości korozji wydłużono te odstępy do 3 4 tygodni. Po ok. roku badania wykazały narastające zagrożenie korozyjne i potwierdziły potrzebę zastosowania ochrony katodowej. Po ok. 3 latach od rozpoczęcia pomiarów korozymetrycznych zbiorniki zostały objęte ochroną katodową (grudzień 2010 r.) i wznowiono wówczas monitorowanie ich szybkości korozji początkowo z częstością raz na kwartał a następnie raz na pół roku, którego celem była ocena skuteczności stosowanego zabezpieczenia przeciwkorozyjnego. 3. Wyniki pomiarów i ich dyskusja Wyniki pomiarów korozymetrycznych wykonanych na badanym obiekcie gromadzone były w internetowej bazie danych rezystometrycznych oraz analizowane z wykorzystaniem kalkulatora ubytków korozyjnych. Opis zastosowanego systemu CORRPOL-ER przedstawiono wcześniej [13]. In this paper an example has been presented of using this technique for solving the problem of four petroleum tanks incorrectly secured against corrosion, mounted on a reinforced concrete plate in one of the Polish heat and power generating plants. Due to savings cathodic protection was not planned during the design stage of this object. Additionally, it was found that during construction the tank structures had been inseparably connected with the reinforced concrete reinforcement forming dangerous corrosion macrocells, in which tanks act as anodes. In the initial research stage the tank corrosion hazard was diagnosed by electrical resistance probes, next they were used for assessment of cathodic protection effectiveness, designed and performed on this basis. 2. Research methodology Electrical resistance probes type ER-10/1,0-FC, produced by SPZP CORRPOL, were used for testing, equipped with steel measuring elements of 10 cm 2 area and 1.0 mm thickness. The location of probes in relation to tanks has been schematically shown in Fig. 1. It covers the most characteristic tank corrosion hazard places connected with their location in the mound on the reinforced concrete plate. In total six such places were selected numbered consecutively from 1 to 6 (half in the lower part of tanks, half in the upper). In each of them two probes were placed in the ground next to each other, of which one connected electrically to the closest tank ( Z marking) reflected the local hazard caused by corrosion macrocells, while the second remained as freely corroding (not connected electrically with the tank ( S marking) allowing determination of the hazard caused by the corrosive environment itself. The MultiCorr MKII meter produced by CORROCEAN (Norway) and the ATLAS 1001 (Poland) [18] were applied for resistance measurements. Electrical resistance measurements were conducted from September 2007. Initially, steel corrosion loss measurements with the use of 12 probes were conducted in 2-week intervals. In the further period, due to observed slower corrosion rate changes, intervals were extended to 3-4 weeks. After a year, tests had shown an increasing corrosion hazard and confirmed the need for cathodic protection application. After approx 3 years from starting corrosion measurements cathodic protection of tanks was installed (December 2010) and then monitoring was restarted of their corrosion rate, initially with a frequency of once per three months and next once per six months, with the aim of assessment of effectiveness of applied anti-corrosion protection. 3. Measurement results and their discussion Results of corrosion measurements performed on the investigated object were collected in an Internet resistance database and analysed with the use of a corrosion loss calculator. The description of the CORRPOL-ER system was presented earlier [13]. Rys. 1. Rozmieszczenie czujników ER przy zakopcowanych zbiornikach widok w przekroju Fig. 1. The ER probes location near mounded tanks a cross-sectional view Ochrona przed Korozją, ISSN 0473-7733, e-issn 2449-9501, vol. 58, nr 8/2015 287

Na rys. 2 zaprezentowane zostały zbiorcze wyniki wykonanych pomiarów na wszystkich 12 czujnikach oraz przykład graficznej ilustracji gromadzonych danych w bazie dla wytypowanych dwóch czujników korozymetrycznych pracujących obok siebie w omawianej instalacji ochrony katodowej. Dla ułatwienia analizy wyniki pomiarów wykonane na czujnikach umieszczonych w taki sam sposób w stosunku do chronionych zbiorników zostały na prezentacji graficznej oznaczone tym samym kolorem. Na zestawieniu zbiorczym porównywane są wartości średnie szybkości korozji zmierzone na wszystkich czujnikach korozymetrycznych (A) w okresie poprzedzającym zastosowanie ochrony katodowej (B) oraz wartości średnie szybkości korozji zmierzone w okresie od momentu włączenia ochrony katodowej do ostatniego pomiaru pod koniec ubiegłego roku (C). Wartości średnie nie odzwierciedlają tutaj wyników uzyskanych przed podjęciem decyzji o konieczności zastosowania ochrony katodowej, ponieważ w zależności od warunków atmosferycznych okresowo odnotowywano szybkości korozji od 0,1 do 0,4 mm/rok. Przedstawiony sposób prezentacji wyników w swoim założeniu miał w jasny sposób wykazywać skuteczność działania zastosowanej ochrony katodowej zbiorników i stanowić dla właściciela obiektywną kontrolę efektywności zastosowanej ochrony przeciwkorozyjnej. Zaprezentowane wyniki pomiarów jednoznacznie na to wskazują niemal na całym Obiekcie spełnione jest kryterium normy PN-EN 15257, tj. szybkość korozji zabezpieczanej powierzchni stalowej jest mniejsza niż 10 μm/rok. In Fig. 2 collective results have been presented of measurements of all 12 probes and an example of a graphical illustration of data collected in the database for two selected electrical resistance probes operating next to each other in the cathodic protection installation. To facilitate analysis, measurement results performed on probes placed in the same way in relation to protected tanks have been shown in the same colour on the graphical presentation. In the collective specification mean corrosion rate values are compared, measured on all electrical resistance probes (A) in the period preceding cathodic protection application and mean corrosion rates measured in the period from the moment of starting cathodic protection to the latest measurement at the end of last year (C). Mean values do not reflect here results obtained before undertaking the decision on necessity of cathodic protection application, because depending on atmospheric conditions, periodically corrosion rates were noted from 0.1 to 0.4 mm/year. The presented results as per assumption - were to clearly show the effectiveness of applied tanks cathodic protection and to comprise for the owner of tanks an objective method of checking the applied anti-corrosion protection. Presented measurement results unequivocally point to this almost on the whole Object the criterion of standard PN-EN 15257 is met, i.e. the corrosion rate of the protected steel surface is below 10 μm/year. Selected corrosion loss measurement results as a function of time for probes placed in three locations have been presented in graphical form in Fig. 3-5. Rys. 2. Wyniki pomiarów korozymetrycznych: A oznaczenie czujnika, B średnia szybkość korozji przed zastosowaniem ochrony katodowej w μm/rok, C średnia szybkość korozji liczona od momentu włączenia polaryzacji katodowej w μm/rok; oraz wykresy zmian ubytków i szybkości korozji czujników podłączonego (2Z) i niepodłączonego (2S) do chronionego zbiornika Fig. 2. Results of ER measurements: A ER probe marking, B average corrosion rate before applying cathodic protection in mμ/year, C average corrosion rate calculated from the moment of turning on the cathodic polarization in μm/year; and the graphs of changes in the corrosion loss and corrosion rate for ER probes connected (2Z) and not connected (2S) to the protected tank 288 Ochrona przed Korozją, ISSN 0473-7733, e-issn 2449-9501, vol. 58, nr 8/2015

Wybrane wyniki pomiarów ubytków korozyjnych w funkcji czasu dla czujników umieszczonych w trzech lokalizacjach przedstawiono w formie graficznej na rys. 3 5. Wykres na rys. 3 obrazuje jak narastały ubytki korozyjne stali w rejonie górnej tylnej części środkowego zbiornika. Żółtą strzałką zaznaczono moment włączenia instalacji ochrony katodowej zbiorników. Uzyskane wyniki okazały się zgodne z przewidywaniami. Czujnik korozymetryczny zwarty ze zbiornikiem (5Z) wykazał w pierwszym roku ekspozycji ok. 5-krotnie większe ubytki korozyjne, a zarazem i szybkość korozji od czujnika swobodnie korodującego (5S). Tak duże przyspieszenie korozji związane było przypuszczalnie z oddziaływaniem galwanicznym zwartych ze zbiornikami konstrukcji żelbetowych (taca i pale), które polaryzują zbiorniki anodowo. Po 3 latach szybkości korozji obu czujników w przybliżeniu wyrównały się. Po włączeniu instalacji ochrony katodowej szybkość korozji czujnika połączonego elektrycznie ze zbiornikiem obniżyła się do pomijalnie niskiej wartości 1,1 μm/rok wskazując na bardzo skuteczne działanie ochrony katodowej w górnej strefie zbiornika, podczas gdy czujnik niepołączony nadal korodował ze stałą szybkością ok. 10 μm/rok. Podobną sytuację stwierdzono w przypadku pary czujników korozymetrycznych (6Z i 6S) ulokowanych w dolnej tylnej części środkowego zbiornika (Rys. 4). Tutaj również ubytki korozyjne czujnika połączonego elektrycznie ze zbiornikiem były w pierwszym okresie kilkakrotnie wyższe od czujnika swobodnie korodującego. Po zastosowaniu ochrony katodowej proces korozji czujnika polaryzowanego wraz ze zbiornikiem uległ praktycznie zahamowaniu, natomiast czujnik niepolaryzowany korodował nadal z szybkością ok. 8 μm/rok. Odmienną sytuację stwierdzono dla pary czujników 2Z i 2S umieszczonych w rejonie dolnej przedniej części skrajnego zbiornika (Rys. 5). W tym przypadku wyznaczone ubytki korozyjne stali w początkowym okresie były dużo wyższe niż w innych lokalizacjach odpowiednio ok. 380 μm dla czujnika połączonego ze zbiornikiem i 180 μm dla niepołączonego po 3 latach ekspozycji. Było to uwarunkowane przypuszczalnie silniejszym lokalnie oddziaływaniem istniejących makroogniw galwanicznych (bliskość frontowej ściany żelbetowej) oraz większą koncentracją czynników korozyjnych w tej części kopca. Po włączeniu instalacji ochrony katodowej okazało się dość nieoczekiwanie, że zahamowanie procesów korozyjnych nastąpiło na obu czujnikach (2Z i 2S), których szybkości korozji już w roku 2012 obniżyły się praktycznie do zera. Dla lepszej ilustracji tego zjawiska zaprezentowano wyniki pomiarów z bazy danych dla tych The graph in Fig. 3 shows how steel corrosion losses increased in the region of the upper back part of the middle tank. The yellow arrow indicates the moment of starting the tank cathodic protection installation. Results obtained were found to be in accordance with predictions. The electrical resistance probe shorted with the tank (5Z) indicated in the first year of exposure approximately five-fold higher corrosion losses, hence the corrosion rate, than the freely corroding probe (5S). Such high corrosion acceleration was probably connected with galvanic interaction of reinforced concrete structures (base and piles) shorted with tanks, polarising the tanks in the anodic direction. After 3 years the corrosion rate of both probes was approximately equal. After starting the cathodic protection installation, the corrosion rate of the ER probe electrically connected with the tank decreased to a negligibly low value of 1.1 μm/year pointing to very effective operation of cathodic protection in the upper tank zone, while the unconnected probe still corroded at a constant rate of approx. 10 μm/year. A similar situation was stated in the case of electrical resistance probes (6Z and 6S) located in the lower back part of the middle tank (Fig. 4). Also here corrosion losses of the probe electrically connected with the tank were in the first period several times higher than the freely corroding probe. After application of cathodic protection the corrosion process of the polarised probe with the tank was practically hindered, while the unpolarised probe still corroded at a rate of approx. 8 μm/year. A different situation has been stated for the ER probe pairs 2Z and 2S placed in the region of the lower front part of the extreme tank see Fig. 5. In this case steel corrosion losses in the initial period were significantly higher than in other locations approx. 380 μm for the probe connected to the tank and 180 μm for that unconnected after 3 years of exposure. This was probably caused by stronger local interaction of existing galvanic macrocells (proximity of the front reinforced concrete wall) and a higher concentration of corrosion factors in this part of the mound. After starting the cathodic protection installation it was unexpectedly found that hindering of corrosion processes occurred on both probes (2Z and 2S), where the corrosion rate already in 2012 decreased practically to zero. To better illustrate this phenomenon measurement results from the database for the same probes have been presented in Fig. 2. Similar results have been obtained on the ER probes 4Z and 4 S, hence in the case of two locations among six selected for investigations. No references were found in corrosion literature on similar cases. Interaction of cathodic protection installations on neighbouring ob- Rys. 3. Ubytki korozyjne stali w funkcji czasu wyznaczone dla czujnika ER zwartego elektrycznie ze zbiornikiem (5Z) i czujnika swobodnie korodującego (5S) Fig. 3. Corrosion losses of steel in function of time determined for ER probe connected electrically to tank (5Z) and for freely corroding probe (5S) Rys. 4. Ubytki korozyjne stali w funkcji czasu wyznaczone dla czujnika ER zwartego elektrycznie ze zbiornikiem (6Z) i czujnika swobodnie korodującego (6S) Fig. 4. Corrosion losses of steel in function of time determined for ER probe connected electrically to tank (6Z) and for freely corroding probe (6S) Ochrona przed Korozją, ISSN 0473-7733, e-issn 2449-9501, vol. 58, nr 8/2015 289

Rys. 5. Ubytki korozyjne stali w funkcji czasu wyznaczone dla czujnika ER zwartego elektrycznie ze zbiornikiem (2Z) i czujnika swobodnie korodującego (2S) Fig. 5. Corrosion losses of steel in function of time determined for ER probe connected electrically to tank (2Z) and for freely corroding probe (2S) samych czujników na rys. 2. Podobne wyniki uzyskano na czujnikach 4Z i 4S, a więc w przypadku dwóch lokalizacji spośród sześciu wytypowanych do badań. Nie natrafiono w literaturze korozyjnej na doniesienia o podobnych przypadkach. Znane są od dawna i szeroko opisane oddziaływania instalacji ochrony katodowej na obiekty sąsiednie o większych gabarytach, w których obserwuje się hamowanie korozji w strefach wpływu prądu i jej przyspieszanie w strefach wypływu. Można próbować wyjaśnić zaobserwowaną anomalię raczej na skutek wtórnych oddziaływań elektrochemicznych niż elektrycznych przyjmując, że na skutek polaryzacji katodowej zbiorników uległa lokalnie obniżeniu agresywność korozyjna środowiska w strefie przyległej do czujnika swobodnie korodującego, na przykład na skutek alkalizacji gruntu, redukcji obecnego tlenu lub migracji chlorków. Nie podjęto dodatkowych badań celem wyjaśnienia tego zjawiska, gdyż nie były one ujęte w programie, a post factum byłoby to technicznie bardzo trudne lub wręcz niewykonalne. Należy mieć jednak świadomość, że takie oddziaływania instalacji ochrony katodowej na elementy metalowe znajdujące się w pobliżu polaryzowanych konstrukcji mogą mieć miejsce w praktyce. W tym przypadku obserwowano je zwłaszcza w dolnych strefach kopca przy dnach zbiorników, gdzie procesy dyfuzji są wolniejsze w stosunku stref górnych. Dlatego też przy prowadzeniu badań porównawczych próbek chronionych i niechronionych katodowo na obiektach podziemnych należałoby te ostatnie odsuwać dalej od chronionych konstrukcji poza strefę ewentualnych zmian środowiskowych, aby uniknąć błędnej (zaniżonej) oceny ich szybkości korozji. 4. Wnioski Zebrane na podstawie ponad siedmioletnich badań wyniki pomiarów rezystometrycznych dotyczące korozji ziemnej zakopcowanych zbiorników i ich analiza upoważniają do sformułowania następujących wniosków: Przyjęta metoda monitorowania korozji ziemnej zbiorników z wykorzystaniem korozymetrii rezystancyjnej pozwoliła na dokładne określenie w wytypowanych lokalizacjach ich zagrożenia korozyjnego przed zastosowaniem ochrony katodowej oraz wymierną ocenę skuteczności jej działania w okresie kilku lat po ich zabezpieczeniu. Zaobserwowano wyraźny wpływ funkcjonowania ochrony katodowej zbiorników na zachowanie korozyjne niektórych czujników ER swobodnie korodujących umieszczonych w gruncie w ich pobliżu. Z bliżej nieokreślonych przyczyn procesy korozji stalowych elementów pomiarowych tych czujników uległy zahamowaniu w stopniu zbliżonym do zbiorników. jects of larger dimensions have been known for a long time and widely described, in which hindering of corrosion is observed in current inflow zones and its acceleration in outflow zones. One may try to explain the observed anomaly more as the result of secondary electrochemical than electrical interactions, assuming that local environment corrosion aggressiveness decreased as the result of cathodic protection in the zone in the proximity of the freely corroding probe, e.g. as the result of soil alkalisation, reduction of present oxygen or migration of chlorides. No additional research has been undertaken to explain this phenomenon, as it was not planned in the program, while post factum this would have been technically very difficult or even impossible. However, one should keep in mind that such interactions of the cathodic protection installation on metal elements located near polarised structures can take place in practice. In this case they were observed particularly in mound lower zones near tank bottoms, where diffusion processes are slower in comparison with upper zones. Hence, when performing comparison tests of samples with and without cathodic protection on underground objects, the latter should be shifted further away from protected structures beyond the zone of possible environmental changes, to avoid erroneous (underrated) corrosion rate assessment. 4. Conclusions Electrical resistance measurement results collected on the basis of over 7-year studies concerning soil corrosion of buried tanks and their analysis allow formulating of the following conclusions: The adopted tank soil corrosion monitoring method with the use of electrical resistance measurements allowed precise determination of the corrosion hazard in chosen locations before cathodic protection application and measurable assessment of its operation effectiveness in the period of several years after their protection. A distinct effect has been observed of tank cathodic protection functioning on corrosion behaviour of some freely corroding ER probes placed in the ground in their proximity. Due to more closely undetermined causes corrosion processes of steel measurement elements of these probes became hindered in a degree similar to tanks. If reference ER probes are applied for assessment of cathodic protection effectiveness of underground structures, one should 290 Ochrona przed Korozją, ISSN 0473-7733, e-issn 2449-9501, vol. 58, nr 8/2015

W przypadku stosowania czujników referencyjnych do oceny skuteczności ochrony katodowej konstrukcji podziemnych należy mieć świadomość, że mogą one w pewnych warunkach dawać zaniżone szybkości korozji. Należy sądzić, że można temu zapobiegać umieszczając czujniki ER w większej odległości od chronionych obiektów. LITERATURA / REFERENCES 1. N.A. Khan: Using Electrical Resistance Soil Corrosion Probes to Determine Cathodic Protection Effectiveness in High-Resistivity Soils, Materials Performance, 43, 6 (2004), 20 25. 2. R.A. Welsh, J. Benefield: Environmental Protection Through Automated Remote Monito ring of Fuel Storage Tank Bottoms Using Electrical Resistance Probes, Materials Performance, 45, 3 (2006), 38 40. 3. N.A. Khan: Using Coupons and ER Soil Corrosion Probes in Applying Pipeline CP Criteria, Materials Performance, 46, 4 (2007), 26 30. 4. Report on Corrosion Probes in Soil or Concrete, NACE International Publication 05107, August 2007. 5. L.V. Nielsen: Application of coupons and probes for cathodic protection monitoring purposes, WG B, CEOCOR, April 2013. 6. R. Juchniewicz, J. Jankowski, W. Sokólski, J. Walaszkowski: Kryteria ochrony katodowej konstrukcji stalowych, Ochr. Przed. Koroz., 36, 6 (1993), 121 125. 7. R. Juchniewicz, W. Sokólski, J. Jankowski: Assesment of cathodic protection criteria. a4. Workshop Corrosion Protection of Pipeline Systems, Praha, 1995. 8. J. Jankowski, J. Szukalski: Zastosowanie korozymetrii rezystancyjnej do pomiarów skuteczności ochrony katodowej konstrukcji podziemnych, Mat. IV Krajowej Konferencji Pomiary korozyjne w ochronie elektrochemicznej, Jurata, czerwiec 1996, 51 58. 9. ST-IGG-0601:2008, Ochrona przed korozją zewnętrzną stalowych gazociągów lądowych. Wymagania funkcjonalne i zalecenia. 10. ST-IGG-0602:2009 Ochrona przed korozją zewnętrzną stalowych gazociągów lądowych. Ochrona katodowa. Projektowanie, budowa, użytkowanie. Informacje o Autorach / About the Authors: Dr inż. Jezmar Jankowski absolwent Wydziału Chemicznego Politechniki Gdańskiej kierunku Korozja i ochrona metali (1970), wieloletni pracownik Katedry Technologii Zabezpieczeń Przeciwkorozyjnych Politechniki Gdańskiej (1970 2004), tematyka badawcza metody oceny szybkości korozji, wykładowca z zakresu metod pomiarowych szybkości korozji metali, współautor podręczników, licznych prac naukowych, ekspertyz i opracowań dla przemysłu oraz patentów i wdrożeń. Kierownik samodzielnych prac badawczych finansowanych przez Komitet Badań Naukowych. Laureat nagród Ministra Nauki i Szkolnictwa Wyższego oraz Ministra Edukacji Narodowej, laureat nagrody NOT. Pracownik SPZP CORRPOL (2004-). Specjalizacja: monitorowanie procesów korozyjnych, badania szybkości korozji metodami elektrochemicznymi, ochrona katodowa rurociągów i zbiorników od strony wody. Dr inż. Wojciech Sokólski absolwent Wydziału Chemicznego Politechniki Gdańskiej kierunku Korozja i ochrona metali (1970), wieloletni keep in mind that in some conditions they can provide underrated corrosion rates. One should presume that it could be possible to prevent this by locating ER probes at larger distances from protected objects. 11. J. Jankowski, W. Sokólski: Monitorowanie skuteczności ochrony katodowej techniką rezystometryczną, Ochr. Przed Koroz., 46, 8 (2003), 218 221. 12. J. Jankowski: Korozymetria jako wiarygodna technika pomiaru skuteczności ochrony katodowej, Materiały VIII Krajowej Konferencji Pomiary Korozyjne w Ochronie Elektrochemicznej, Jurata 2004, 29 39. 13. J. Jankowski, W. Sokólski: System CORRPOL-ER - internetowa baza danych rezystometrycznych wraz z kalkulatorem ubytków korozyjnych, Ochr. Przed. Koroz., 49, 8 (2006), 269 271. 14. J. Jankowski: Dobór systemu korozymetrii rezystancyjnej do monitorowania skuteczności ochrony katodowej, Materiały III Dorocznej Konferencji Naukowo-Technicznej Współczesne Technologie Przeciwkorozyjne, Jurata 2009. 15. W. Sokólski, J. Jankowski: Stara metoda w nowej odsłonie zastosowanie korozymetrii w technologii ochrony katodowej, 52, 4-5, (2009), 20 24. 16. M. Fiedorowicz, M. Jagiełło: Korozymetria rezystancyjna w badaniach korozji podziemnych rurociągów, Ochr. Przed. Koroz., 53, 8 (2010), 391 397. 17. J. Jankowski, W. Sokólski, A. Hoffmann: Application of electrical resistance technique to monitoring of cathodic protection effectiveness, 20 th Workshop Corrosion Protection of Buried Structures, Praga 2011. 18. SPZP CORRPOL: http://www.corrpol.pl/czujniki.htm pracownik i nauczyciel akademicki w Katedrze Technologii Zabezpieczeń Przeciwkorozyjnych Politechniki Gdańskiej (1970-2001), wykładowca z zakresu elektrochemicznej ochrony przed korozją, metod pomiarowych i technik komputerowych wykorzystywanych w technologii ochrony katodowej, współautor podręczników, licznych prac naukowych i popularno-naukowych, ekspertyz i opracowań dla przemysłu oraz patentów i wdrożeń. Kierownik samodzielnych prac badawczych finansowanych przez Komitet Badań Naukowych. Laureat szeregu nagród Ministra Nauki i Szkolnictwa Wyższego oraz Ministra Edukacji Narodowej. Kierownik Zakładu Korozji Morskiej w Instytucie Morskim w Gdańsku (1993 2003). Wiceprezes Zarządu i Dyrektor ds. Techniki i Rozwoju SPZP CORRPOL (2002-). Specjalizacja: ochrona katodowa konstrukcji i urządzeń stalowych w wodzie i ziemi, prądy błądzące, metody pomiarowe, wykorzystanie technik mikrokomputerowych w technologii ochrony katodowej. e-mail: wsok@corrpol.pl Otrzymano/ Received: 29.06.2015 Przyjęto / Accepted: 30.07.2015 O ochronie elektrochemicznej publikowaliśmy: Modelowanie oddziaływań elektromagnetycznych na rurociągi podziemne z uwzględnieniem korozji przemiennoprądowej, K. Budnik, W. Machczyński, nr 8/2012, s. 332 Ochrona katodowa potencjały konstrukcji, M. Fiedorowicz, nr 8/2012, s. 340 Zastosowanie techniki korozymetrii rezystancyjnej do monitorowania skuteczności ochrony katodowej, J. Jankowski, W. Sokólski, A. Hoffmann, nr 8/2012, s. 347 Skutki błędnych projektów i niefachowego wykonawstwa ochrony katodowej zakopanych konstrukcji metalowych, W. Sokólski, nr 8/2012, s. 351 Badanie jakości anod magnezowych wg normy PN-EN 12438, P.T. Sanecki, P.M. Skitał, Z. Pudłowski, nr 8/2012, s. 356 Ochrona korozyjna obiektów morskich przegląd problemów, T. Kaniak, T. Graczyk, nr 8/2012, s. 358 MiniLog2 urządzenie dla profesjonalistów, M. Nitschke, nr 8/2012, s. 362 Ocena skuteczności ochrony katodowej propozycja metody instrumentalnej, W. Sokólski, J. Jankowski, J. Rozwadowski, nr 5/2012, s. 229 Metody badania interferencji wywoływanych przez prądy błądzące na przykładzie pomiarów wykonanych na terenie Mazowieckiej Spółki Gazownictwa sp. z o.o., K. Żakowski, K. Darowicki, T. Brodnicki, nr 3/2012, s. 97 Zainteresowanych ww. artykułami informujemy, że archiwalne egzemplarze Ochrony przed Korozją można zamówić w redakcji, tel./fax: 032 231 02 24. Egzemplarze wysyłamy wraz z fakturą. Ochrona przed Korozją, ISSN 0473-7733, e-issn 2449-9501, vol. 58, nr 8/2015 291