DMX SPLITTER 8 Users Manual

Podobne dokumenty
BLACKLIGHT SPOT 400W F

LED WASHER 30x3W WHITE IP65 F

LED MAGIC BALL MP3 F

INSTRUCTION MANUAL. Strona 1

LED PAR 56 7x10 4in1 RGBW F

WYŁĄCZNIK CZASOWY OUTDOOR TIMER

HAPPY ANIMALS L01 HAPPY ANIMALS L03 HAPPY ANIMALS L05 HAPPY ANIMALS L07

HAPPY ANIMALS L02 HAPPY ANIMALS L04 HAPPY ANIMALS L06 HAPPY ANIMALS L08

LED PAR 18x10W RGBW 4in1 Aluminum single cast II ver. F

LED MINI DERBY 4x3W RGBW F

LED WALL WASHER 36x3W RGBW 3SC IP65 F

USER MANUAL / INSTRUKCJA OBSŁUGI. LED Double Derby 2x10W 4in1 F

LED WASHER RGB IP34 F

FOG MACHINE FLZ-1500 DMX+ RE F

LED PAR 36 12x3W RGBW F

LED PAR 64 18x10W 4in1 CLASSIC F

LED PAR 18x10W RGBW 4in1 IP65 F

LED PAR 18x 10W RGBW 4in1 Aluminium single cast v.iii F B

LED Spyder 8x10 CREE 4in1 F

DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE!

LED PAR 64 18x10W RGBW 4in1 IP64 PFC F

LED PAR 56 7*10W RGBW 4in1 SLIM

LED PAR 64 18x12W RGBW 4in1 ZOOM IP65 F

LED PAR 64 7x10W RGBW 4in1 ABS Remote Control F

LED PAR Set 4x PAR 36 12x3W F

LED PAR 64 7x10W RGBW 4in1 ABS F

LED Spyder Mini 8x3W 4in1 RGBW F


DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE!

HAPPY K04 INSTRUKCJA MONTAŻU ASSEMBLY INSTRUCTIONS DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE! W5 W6 G1 T2 U1 U2 TZ1

FOG MACHINE FLZ-2000 DMX + LED 3in1 RGB F

LED WALL WASHER 9x10W RGBW 4in1 DMX WIFI + ACU IP65 F a

LED MOVING HEAD 60W F

LED PAR 56 Slim 18X3W RGB Aura F a

DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE!

FOG MACHINE FLM RE II ver. F

DC UPS. User Manual. Page 1

2x Moving Head 15R BEAM FL Case F

Bruksanvisning för lysrörsarmatur 2 x 18 W. Instrukcja obsługi oprawy świetlówkowej 2 x 18 W. Operating Instructions for Strip Light 2 x 18 W

4 BEAM 4x10W LUMILUX LED RGBW 4in1 F

099 Łóżko półpiętrowe 2080x1010(1109)x Bunk bed 2080x1010(1109)x1600 W15 INSTRUKCJA MONTAŻU ASSEMBLY INSTRUCTION

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

LED PIXEL 30W RGBW 4in1 COB AutoDMX FastLOCK P

Céliane TM Vac 50-60Hz. 1 x 2.5 mm 2 2 x 1.5 mm 2. Max. 400 W 400 W 400 VA 400 VA. 240 Vac. Min. 40 W 40 W 40 VA 40 VA

FOG MACHINE FLZ-1500 DMX LED+RE F

2x Moving Head 7R FL-233 BEAM+ Case F

Hippo Boombox MM209N CD. Instrukcja obsługi User s Manual

LED PAR 36 4x15W 4in1 ZOOM F

Fog Machine FLZ-2000 RGB LED 3in1 F

098 Łóżko piętrowe 2080x1010(1109)x Double bunk bed 2080x1010(1109)x1600 W15 MONTAGEANLEITUNG ASSEMBLY INSTRUCTION

Tuber radio BT MA407. Instrukcja obsługi User s Manual

LED MOVING HEAD STRONG 108x3W RGBW WASH III F c

POWER BANK KM0209-KM0211

LED Double-sided WASH-BEAM Moving Head 4x10W + 1x10W F

POWER BANK. Owner s manual Instrukcja obsługi EN PL

INSTRUKCJA UŻYTKOWNIKA

LED MH 7x10W RGBW 4in1 F

Instrukcja obsługi. ibind A8/A12/A15/A20. instruction manual GDAŃSK ul. Krynicka 1 tel.: (058) fax: (058)

Instrukcja obsługi. binding machine KRIS. instruction manual GDAŃSK ul. Krynicka 1 tel.: (058) fax: (058) ODDZIAŁ:

INSTRUKCJA OBSŁUGI OPERATIONAL MANUAL KRZESEŁKO / HIGH CHAIR MINI WYPRODUKOWANO ZGODNIE Z NORMĄ PN-EN 14988

Instrukcja obsługi TOSTER MODEL: BH-8863

Zasady bezpieczeństwa

Instrukcja obsługi User s manual

LED Moving Head 120W SPOT MK2 F

user s manual NV-002MIC

Installation of EuroCert software for qualified electronic signature

Universal Bluetooth speaker

15R MOVING HEAD "ALL IN ONE" F

FOG MACHINES User manual. FLM-600 Maszyna do dymu Instrukcja obsługi

MM210. Instrukcja obsługi User s Manual

VW3A7703 Akcesoria VW3A Rezystor hamowania IP20 28 Ohm 200W

Selfie Monopod MA426. Instrukcja obsługi User s Manual

EK1301/1302/1303 CZAJNIK BEZPRZEWODOWY INSTRUKCJA OBSŁUGI KETTLE - INSTRUCTION MANUAL POLSKI... STR. 2 ENGLISH... P. 5

LED STROBE COB White 200W P

Presenter SNP6000. Register your product and get support at Instrukcja obsługi

LED MATRIX Moving Head 25x12W 4in1 NO LIMIT F

Mouse Tracer Fiorano RF

TR18 INSTALATION MANUAL / INSTRUKCJA MONTAŻU. cart for flat displays

Camspot 4.4 Camspot 4.5

Instalacja Właściwości

Car MP3 Player MM211. Aby zapewnić prawidłową obsługę sprzętu zapoznaj się dokładnie z instrukcją i zachowaj ją na przyszłość.

WiFi DMX USER MANUAL. Strona 1

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

Zwora Yale US06. Yale seria US kg. Zastosowanie. Właściwości. Parametry techniczne

POLITYKA PRYWATNOŚCI / PRIVACY POLICY

Jazz EB207S is a slim, compact and outstanding looking SATA to USB 2.0 HDD enclosure. The case is

Moving Head FL-232 BEAM 7R F

FOLLOW SPOT FL-1200 DMX

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

SG-MICRO... SPRĘŻYNY GAZOWE P.103

LED MOVING HEAD MINI BEAM 18x3W RGB CREE F

Zakopane, plan miasta: Skala ok. 1: = City map (Polish Edition)

Instrukcja obsługi. Xperia P TV Dock DK21

Xperia TX TV Dock DK22 Xperia T TV Dock DK23

[ROBOKIDS MANUAL] ROBOROBO

Instrukcja obsługi MM1500

Instrukcja obsługi. MHL to HDMI Adapter IM750

PL - GENESIS HX55 - INSTRUKCJA OBSŁUGI

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

SkillGuide. Podręcznik użytkownika. Polski

Transkrypt:

DMX SPLITTER 8 Users Manual www.flash-butrym.pl Strona 1

Thank you for choosing one of our DMX splitters. Please read this user manual carefully and follow the instructions to avoid danger or damage to the unit due to mishandling. Keep this user guide for future reference. 1. Safety Instructions Please carefully read the instruction, which includes important information about the installation, usage and maintenance, BEFORE operating this device. *This device is exclusively meant to be used as a splitter for DMX signals within the limits given in this manual. Using it in any other way you risk electric shock and warranty will become void. *Never sever or manipulate the power cord or the plug. If a power cord is provided with an earth lead, this is mandatory to ensure safe operation! Otherwise a LIFE THREATENING situation exists! *Unpack and check carefully there is no transportation damage before using the unit. Never put a damaged device into operation. *Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit as stated in this manual. *The unit is for indoor use only. Use it only in a dry location. Exposing the device to rain or moisture would cause the risk of electrical shock or fire. *DO NOT let any liquids or objects enter the unit. Should any liquid be spilled on the unit, DISCONNECT the power supply to the unit immediately and contact the service company. *The unit must only be installed in a location with adequate ventilation. Be sure that no ventilation slots are blocked. In order to guarantee adequate ventilation, allow a free air space of at least 20 cm around the sides and top of the unit. *Disconnect the device from the mains power before any servicing or maintenance. Notice regarding power disconnection: To disconnect the device from the power source the power plug must be removed from the power socket. For this reason the device must be placed in a position where a constant unobstructed access to the power socket is assured, thus in an emergency situation you are able to immediately pull out the power plug. To eliminate the risk of fire you must completely disconnect the power plug from the power socket after the device has been used. *Always grasp the power cord by the plug. Do not pull on the cord itself and never touch the power cord with wet hands as this could result in a short circuit or an electrical shock. Do not place the device, speaker cabinets or anything else on the power cord and make sure that it does not become clamped. 2. Introduction The DMX distributor offers one input and eight outputs. Both inputs and outputs as well as outputs among each other are completely eclectically isolated. Each DMX output features an independent driver and DATA+ & DATA- indicator. Using the built-in switch you can easily terminate the LINK OUT, when you don t want to transmit the DMX signal to other units. www.flash-butrym.pl Strona 2

3. Technical Specyfications Power supply voltage : Fuse (internal) AC 90-230 V~, 50 Hz F 500 ma, 250 V 4. Operating instruction and connection You can run a maximum of 32 units (receiver) per output channel. Use a terminator on the last receiver. If you don t connect other units to the DMX LINK OUT socket, you have to press the switch underneath the socket, to terminate this output. You may only connect the device to a properly wired and earthed mains power wall outlet, after all DMX connections have been established. The wall outlet must provide the correct mains voltage as stated in this manual. DMX OUT: connect the DMX receiving device(s) here DMX IN: connect the DMX transmitting device here This is the unit s pin assignment: Pin 1: Ground/Shielding Pin 2: Data Pin 3: Data + www.flash-butrym.pl Strona 3

5. Disposal Do not dispose of the device at the end of his operating life in your normal domestic waste. This device is subject to the European Guidelines 2002/96/EC. *Have the product disposed of by a professional disposal company of by your communal disposal facility. *Observe the currently applicable regulations. In case of doubt contact your disposal facility. *Dispose of packaging materials in an environmentally responsible manner. www.flash-butrym.pl Strona 4

DMX SPLITTER 8 Instrukcja Obsługi www.flash-butrym.pl Strona 5

Dziękujemy za wybranie jednego z naszych Spliterów DMX. Prosimy o dokładne zapoznanie się z niniejszą instrukcją aby uniknąć jakiegokolwiek niepotrzebnego ryzyka uszczerbku na zdrowiu, lub ryzyka uszkodzenia urządzenia. 1. Instrukcje dotyczące bezpieczeństwa Prosimy o wnikliwe zapoznanie się z niniejszymi zaleceniami dotyczącymi podłączenia urządzenia, jego użytkowania i konserwacji. *Urządzenie to jest przeznaczone do pracy tylko i wyłącznie jako Spliter sygnałów DMX ( według limitów podanych w tej instrukcji ). Jego użytkowanie w jakikolwiek inny sposób grozi porażeniem prądu i utratą gwarancji. *Nie należy ucinać lub zmieniać przewodu zasilającego. Przewóz zasilający jest uziemiony, co jest wymagane w tego typu urządzeniach. Bez niego występuje ryzyko porażenia prądem. *Przy rozpakowywaniu urządzenia należy je obejrzeć czy nie zostało uszkodzone podczas transport. Nigdy nie należy podłączać uszkodzonego urządzenia. *Przed podłączeniem należy upewnić się że napięcie i częstotliwość źrodła zasilania spełniają wymogi zasilania podane w tej instrukcji. *Urządzenie jest przeznaczone wyłącznie do pracy wewnątrz suchych pomieszczeń. Jego praca w warunkach mokrych lub wilgotnych grozi porażeniem i pożarem. *ZABRANIA się kontaktu urządzenia z wszelkimi cieczami. Jeżeli jakakolwiek ciecz dostałaby się do środka, należy je natychmiast wyłączyć i skontaktować się z autoryzowanym serwisem. *Urządzenie musi być podłączone w pomieszczeniu o odpowiedniej wentylacji. Należy zapewnić minimalną odległość 20 cm wolnej przestrzeni z każdej strony splitera. *Przed jakąkolwiek konserwacją czy naprawą należy sprzęt odłączyć od zasilania. Sposób odłączenia zasilania: Aby odłączyć urządzenie od źródła zasilania, wtyczka zasilająca musi zostać odłączona od źródła. W tym celu urządzenie musi znajdować się w położeniu, w którym możliwy jest łatwy dostęp do wtyczki zasilającej. Co podczas ewentualnej sytuacji kryzysowej ułatwi szybkie i łatwe odłączenie zasilania. Aby wyeliminować możliwość pożaru należy od razu odłączyć urządzenie od zasilania przy pierwszych objawach wadliwej pracy. *Przewód zasilania łapiemy wyłącznie za wtyczkę. Nigdy nie należy ciągnąć za sam przewód zasilania, oraz odradza się dotykania czegokolwiek mokrymi rękami, jako iż może to doprowadzić do porażenia prądem. Nie należy umieszczać urządzenia w żadnych pojemnikach, w których przewód zasilania będzie odkształcony lub pogięty. 2. Wprowadzenie Dystrybutor DMX przekształca jeden sygnał wejściowy w 8 wyjściowych. Zarówno sygnały wejściowe jak i wyjściowe są elektrycznie separowane i izolowane. Każdy DMWowy sygnał wyjściowy posiada niezależny port i wskaźnik DATA+ & DATA-. Using Za pomocą wbudowanego przełącznika można łatwo odłączyć sygnał LINK OUT, gdy nie chce się dłużej transmitować sygnału do innych urządzeń. www.flash-butrym.pl Strona 6

3. Specyfikacje techniczne Napięcie zasilania : Wewnętrzny bezpiecznik : AC 90-230 V~, 50 Hz F 500 ma, 250 V 4. Instrukcje użytkowania i podłączenia Do jednego wyjścia sygnałowego można podłączyć maksymalnie 32 odbiorniki. Do ostatniego odbiornika trzeba podłączyć conajmniej jeden terminator. Jeżeli żadne dodatkowe odbiorniki nie są podłączone do wtyczki DMX LINK OUT, należy przełączyć przycisk pod daną wtyczką, aby wyłączyć jej sygnał wyjściowy. Urządzenie należy podłączyć do odpowiednio uziemionego źródła zasilania, Dopiero po ustalenie wszystkich połączeni DMXowych. Źródło zasilania musi być odpowiadające specyfikacjom zawartym w tej instrukcji. DMX OUT: podłącznie odbiorników sygnału DMX DMX IN: podłącznie urządzenia nadawającego sygnał DMX Rozstaw pinów na wtyczkach: Pin 1: Uziemienie Pin 2: Data Pin 3: Data + www.flash-butrym.pl Strona 7

5. Utylizacja Po zakończeniu okresu przydatności nie należy urządzenia pozbywać się w domowych warunkach. Urządzenie to podlega europejskim normom utylizacji2002/96/ec. *Urządzenie należy zutylizować poprzez odpowiednio do tego przystosowaną firmę lub zakład. *W danej firmie bądź zakładzie utylizacji należy sprawdzić wszystkie przepisy i postanowienia dotyczące możliwości zutylizowania tego urządzenia. www.flash-butrym.pl Strona 8