Comparison of shallow foundation design using Eurocode 7 and Polish Standard

Podobne dokumenty
Zakład Geotechniki, Politechnika Białostocka Division of Geotechnics, Bialystok University of Technology

PRACE NAUKOWO-PRZEGLĄDOWE

Katedra Geoinżynierii SGGW w Warszawie Department of Geotechnical Engineering WULS SGGW

Warunki geotechniczne posadowienia obiektów związanych z rozbudową budynku D Uniwersytetu Rolniczego przy ul. Balickiej 116 w Krakowie

Agnieszka DĄBSKA. 1. Wprowadzenie

Knovel Math: Jakość produktu

POSADOWIENIE BUDYNKU SZKOLNEGO W UJĘCIU NORM: PN-59/B-03020, PN-81/B i PN-EN

WPŁYW WSKAŹNIKA PLASTYCZNOŚCI NA PARAMETRY WYTRZYMAŁOŚCIOWE GRUNTÓW

STOSOWANIE WSPÓŁCZYNNIKÓW CZĘŚCIOWYCH DO PARAMETRÓW GEOTECHNICZNYCH WEDŁUG EUROKODU 7 W OBLICZENIACH STATECZNOŚCI METODĄ ELEMENTÓW SKOŃCZONYCH

Fig 5 Spectrograms of the original signal (top) extracted shaft-related GAD components (middle) and

Przewody do linii napowietrznych Przewody z drutów okrągłych skręconych współosiowo

TEMATY PRAC DYPLOMOWYCH na kierunku Budownictwo WBiA ZUT w Szczecinie zgłoszone na semestr letni w roku akademickim 2018/2019 (lista uzupełniająca)

EXAMPLES OF CABRI GEOMETRE II APPLICATION IN GEOMETRIC SCIENTIFIC RESEARCH

Załącznik D (EC 7) Przykład analitycznej metody obliczania oporu podłoża

Weronika Mysliwiec, klasa 8W, rok szkolny 2018/2019

ROZPRAWY NR 128. Stanis³aw Mroziñski

Metody obliczania izolacyjności akustycznej między pomieszczeniami w budynku według PN-EN :2002 i PN-EN :2002

ZASTOSOWANIE RÓWNANIA BOUSSINESQUE A DO OKREŚLANIA NAPRĘŻEŃ W GLEBIE WYWOŁANYCH ODDZIAŁYWANIEM ZESTAWÓW MASZYN

Tychy, plan miasta: Skala 1: (Polish Edition)

DUAL SIMILARITY OF VOLTAGE TO CURRENT AND CURRENT TO VOLTAGE TRANSFER FUNCTION OF HYBRID ACTIVE TWO- PORTS WITH CONVERSION

PROGNOZA NOŚNOŚCI PALI NA PODSTAWIE BADAŃ POLOWYCH WEDŁUG NORM PN-EN-1997 I PN-B-02482

Ocena stateczności nasypu na podłożu organicznym według Eurokodu 7 1 Stability assessment of embankment on organic soils using Eurocode 7

Zmiany techniczne wprowadzone w wersji Comarch ERP Altum

Network Services for Spatial Data in European Geo-Portals and their Compliance with ISO and OGC Standards

Proposal of thesis topic for mgr in. (MSE) programme in Telecommunications and Computer Science

DEKLARACJA WŁAŚCIWOŚCI UŻYTKOWYCH HECO-DoP_ETA_15/0784_MMS-plus_1804_PL

Hard-Margin Support Vector Machines

, u. sposób wyznaczania: x r = m. x n, Zgodnie z [1] stosuje się następujące metody ustalania parametrów geotechnicznych:

WSPÓŁCZYNNIK NIEPEWNOŚCI MODELU OBLICZENIOWEGO NOŚNOŚCI KONSTRUKCJI - PROPOZYCJA WYZNACZANIA

The analysis of the energy demand for heating and cooling of the house built on the basis of the traditional Canadian wood-frame construction

Wykorzystanie metody funkcji transformacyjnych do analizy nośności i osiadań pali CFA

Few-fermion thermometry

Praktyczne aspekty wymiarowania belek żelbetowych podwójnie zbrojonych w świetle PN-EN

Rozpoznawanie twarzy metodą PCA Michał Bereta 1. Testowanie statystycznej istotności różnic między jakością klasyfikatorów

NACISK ŁAWY FUNDAMENTOWEJ NA PIASKI THE PRESSURE OF STRIP FOUNDATION ON SANDS. 1. Wprowadzenie Nr kol. 1735

PORTS AS LOGISTICS CENTERS FOR CONSTRUCTION AND OPERATION OF THE OFFSHORE WIND FARMS - CASE OF SASSNITZ

Zakopane, plan miasta: Skala ok. 1: = City map (Polish Edition)

The impact of the global gravity field models on the orbit determination of LAGEOS satellites

STANY GRANICZNE HYD W OBLICZENIACH STATECZNOŚCI DNA WYKOPU

Białystok, r. Wykaz publikacji w języku polskim na temat Eurokodu 7 i norm związanych

Helena Boguta, klasa 8W, rok szkolny 2018/2019

INSPECTION METHODS FOR QUALITY CONTROL OF FIBRE METAL LAMINATES IN AEROSPACE COMPONENTS

photo graphic Jan Witkowski Project for exhibition compositions typography colors : : janwi@janwi.com

Lecture 18 Review for Exam 1

Zarządzanie sieciami telekomunikacyjnymi


NOŚNOŚĆ NA PRZESUNIĘCIE FUNDAMENTÓW BEZPOŚREDNICH

OpenPoland.net API Documentation

ROZPRAWA DOKTORSKA. Model obliczeniowy ogrzewań mikroprzewodowych

ZGŁOSZENIE WSPÓLNEGO POLSKO -. PROJEKTU NA LATA: APPLICATION FOR A JOINT POLISH -... PROJECT FOR THE YEARS:.

Planning and Cabling Networks

Outline of a method for fatigue life determination for selected aircraft s elements


POPRAWKA do POLSKIEJ NORMY

Politechnika Krakowska im. Tadeusza Kościuszki. Karta przedmiotu. obowiązuje studentów rozpoczynających studia w roku akademickim 2017/2018

CEE 111/211 Agenda Feb 17

Analysis of Movie Profitability STAT 469 IN CLASS ANALYSIS #2

Metodyki projektowania i modelowania systemów Cyganek & Kasperek & Rajda 2013 Katedra Elektroniki AGH

WPŁYW METODYKI OZNACZANIA GRANIC ATTERBERGA NA UZYSKIWANE WARTOŚCI STOPNIA PLASTYCZNOŚCI

XXVII INTERPRETACJA WYNIKÓW PRÓBNYCH OBCIĄŻEŃ PALI WEDŁUG NORMY PN-EN PRZYCZYNĄ POTENCJALNEJ KATASTROFY

European Crime Prevention Award (ECPA) Annex I - new version 2014

TECHNICAL CATALOGUE WHITEHEART MALLEABLE CAST IRON FITTINGS EE

Latent Dirichlet Allocation Models and their Evaluation IT for Practice 2016

Ocena no no ci pod o a gruntowego pod fundamentem bezpo rednim w nawi zaniu do norm europejskich

Fundamentem nazywamy tę część konstrukcji budowlanej lub inżynierskiej, która wsparta jest bezpośrednio na gruncie i znajduje się najczęściej poniżej

POMIAR CIŚNIENIA WODY W PORACH METODĄ SONDOWANIA STATYCZNEGO W ASPEKCIE OCENY WYTRZYMAŁOŚCIOWEJ GRUNTÓW

XXIII Konferencja Naukowa POJAZDY SZYNOWE 2018

WSCHÓD I ZACHÓD SŁOŃCA SUNRISE / SUNSET


Struktury proponowane dla unikalnych rozwiązań architektonicznych.

Katedra Geotechniki i Budownictwa Drogowego

Domy inaczej pomyślane A different type of housing CEZARY SANKOWSKI

WSCHÓD I ZACHÓD SŁOŃCA SUNRISE / SUNSET

STATISTICAL METHODS IN BIOLOGY

WENTYLATORY PROMIENIOWE SINGLE-INLET DRUM BĘBNOWE JEDNOSTRUMIENIOWE CENTRIFUGAL FAN

DOI: / /32/37

WSCHÓD I ZACHÓD SŁOŃCA SUNRISE / SUNSET

Instrukcja obsługi User s manual

Wprowadzenie do programu RapidMiner, część 2 Michał Bereta 1. Wykorzystanie wykresu ROC do porównania modeli klasyfikatorów

THE STUDY OF SLIDE BEARING PROPERTIES INCLUDING THE SURFACE TEXTURE GEOMETRY OF A JOURNAL

RESONANCE OF TORSIONAL VIBRATION OF SHAFTS COUPLED BY MECHANISMS

Country fact sheet. Noise in Europe overview of policy-related data. Poland

Strategic planning. Jolanta Żyśko University of Physical Education in Warsaw

ANALIZA NO NO CI POD O A WYBRANYCH STÓP FUNDAMENTOWYCH CENTRUM WODY SGGW W WARSZAWIE WED UG PN-81/B ORAZ EUROKODU 7

y = The Chain Rule Show all work. No calculator unless otherwise stated. If asked to Explain your answer, write in complete sentences.

Sargent Opens Sonairte Farmers' Market

General Certificate of Education Ordinary Level ADDITIONAL MATHEMATICS 4037/12

Akademia Morska w Szczecinie. Wydział Mechaniczny

Projektowanie geometrii fundamentu bezpośredniego


Obciążenie śniegiem w Polsce w projektowaniu i diagnostyce konstrukcji

PRÓBY EKSPLOATACYJNE KOMPOZYTOWYCH WSTAWEK HAMULCOWYCH TOWAROWEGO

WSCHÓD I ZACHÓD SŁOŃCA SUNRISE / SUNSET

Towards Stability Analysis of Data Transport Mechanisms: a Fluid Model and an Application

Appendix. Studia i Materiały Centrum Edukacji Przyrodniczo-Leśnej R. 10. Zeszyt 2 (17) /

ARNOLD. EDUKACJA KULTURYSTY (POLSKA WERSJA JEZYKOWA) BY DOUGLAS KENT HALL

WSCHÓD I ZACHÓD SŁOŃCA SUNRISE / SUNSET

Instrukcja konfiguracji usługi Wirtualnej Sieci Prywatnej w systemie Mac OSX

Raport bieżący: 44/2018 Data: g. 21:03 Skrócona nazwa emitenta: SERINUS ENERGY plc

DM-ML, DM-FL. Auxiliary Equipment and Accessories. Damper Drives. Dimensions. Descritpion

Transkrypt:

Polish Academy of Sciences, Committee for and Reclamation JOURNA OF WATER AND AND DEVEOPMENT and Environmental Engineering in Agriculture, 2014 J. Water and Dev. 2014, No. 20 (I III): 57 62 Institute of Technology and ife Science, 2014 P ISSN 1429 7426 Available (PDF): www.itep.edu.pl/wydawnictwo; http://www.degruyter.com/view/j/jwld Received 13.12.2013 Reviewed 20.01.2014 Accepted 10.02.2014 A study design data collection C statistical analysis D data interpretation E manuscript preparation F literature search Comparison of shallow foundation design using Eurocode 7 and Polish Standard Andrzej OCHAWA 1) ADEF 2) ADEF, Andrzej ZAWASKI 1) University of Technology and ife Sciences, Department of Geotechnics, al. prof. S. Kaliskiego 7, 85-789 ydgoszcz, Poland; tel. +48 52 340-84-08, e-mail: andyolchawa@wp.pl 2) University of Technology and ife Sciences, Department of Geotechnics, al. prof. S. Kaliskiego 7, 85-789 ydgoszcz, Poland; tel. +48 52 340-84-07, e-mail: zawalski@utp.edu.pl For citation: Olchawa A., Zawalski A. 2014. Comparison of shallow foundation design using Eurocode 7 and Polish Standard. Journal of Water and and Development. No. 20 p. 57 62. Abstract earing capacity of cohesive soils was calculated based on PN--03020:1981P and Eurocode 7. Strength parameters of cohesive soil modified by the authors: shear strength in undrained conditions c u, effective cohesion c' and effective friction angle ' were adopted for calculations acc. to Eurocode 7. Values of these parameters depend on a leading parameter liquidity index I. earing capacity was calculated for two pad foundations of a size = 2.0 3.0 m and 1.5 2.0 m and for one 2.0 14.0 m strip foundation. The capacity calculated acc. to EC 7 was reduced by multiplying by a factor α = 0.87 to account for different bearing capacity coefficients in Polish Norms and Eurocodes. Performed calculations showed comparable bearing capacity of substratum irrespective of adopted norms EC 7 and PN for foundation pads. In all analysed cases, however, the bearing capacity of foundation strips calculated acc. to Eurocode 7 was higher than those calculated acc. to PN--03020:1981P. The reason is in the values and ways of accounting partial security coefficients and in differences in the values of shape coefficients used in the equation for ultimate bearing resistance of soil substratum. Key words: bearing resistance, cohesive soils, Eurocode 7, geotechnical design, shallow foundations INTRODUCTION ong observations of constructions did not show damages or disasters associated with designing foundations based on Polish Standard PN--03020: 1981P [WYSOKIŃSKI 2005]. Hence, it is justified to assume that safe foundation of a construction is provided when the value of bearing resistance calculated acc. to PN-EN 1997-1 is comparable with that calculated acc. to PN--03020:1981P. Coming from such assumptions the authors calculated bearing capacity of soils acc. to PN-- 03020:1981P and to Eurocode 7 (EC 7). For calculations acc. to EC 7, soil parameters were taken from available literature [KOSTRZEWSKI 1980; PISARCZYK, RYMSZA 1993]. Comparative analysis of bearing capacity of soils calculated acc. to both norms showed that they are insufficiently comparable [OCHAWA, ZAWASKI 2014]. Therefore, an attempt has been undertaken to correct shear strength parameters of cohesive soils, c and c u. Modification consisted in selecting parameters in such a way that bearing capacity of soils calculated acc., to EC 7 would be comparable with that calculated acc. to PN--03020:1981P. The purpose of this paper is to propose shear strength parameters of cohesive soils to be used for computing ultimate bearing resistance according to Eurocode 7. The proposed nomographs can be used Polish Academy of Sciences (PAN) in Warsaw, 2014; Institute of Technology and ife Science (ITP) in Falenty, 2014

58 A. OCHAWA, A. ZAWASKI for foundation design of Geotechnical Category 1 structures as well as some types of Geotechnical Category 2 (e.g. residential buildings with uncomplicated ground conditions). Difficulties in Eurocode 7 implementation for practical foundation design in Poland was discussed by GOSK [2010], KŁOSIŃSKI [2013], KOTICKI [2005; 2009], SUEWSKA and KONOPKA [2013]. METHODS OF CACUATION The norm PN-EN 1997-1:2008P Eurocode 7 estimates that the ultimate limit state US will be fulfilled if: V d R d (1) where: V d design value of vertical load acting normal to the foundation base, R d design value of the resistance to an action. earing resistance is calculated acc. to Eurocode 7 in drained conditions (long-term design situation) and additionally in undrained conditions (short-term design situation). According to PN--03020:1981P, checking the ultimate limit state of bearing capacity consists in the comparison of the vertical component of computational bearing resistance of soil substratum Q fn and computational vertical component of load N r acc. to equation: N r m Q fn (2) where: m correction factor dependent on the method of calculation of bearing capacity and estimation of geotechnical parameters. In Eurocode 7, partial coefficients are used for interactions of soil and resistance parameters. In the Country Appendix PN-EN 1997-1:2008/ NA:2011P point N.A.2.6, computational approach DA2* is recommended as a design method. In this approach, computational value of interaction, dealt with as unfavourable, is estimated using coefficient 1.35 for constant loads and 1.50 for variable loads. Computational value of ultimate bearing resistance is calculated based on characteristic geotechnical soil parameters and then the obtained value is divided by 1.4. The problems concerning design approaches in Eurocode 7 were discussed by GAAS, KIZIEWICZ [2009], GARWACKA-PIÓRKOWSKA [2011], KUCHER, KUSZYK [2006], VOGT et al. [2006]. In PN--03020:1981P, presented method is based on static computational estimates of soil parameters and loads acting on a construction. Estimation of these values is accomplished by introducing the probabilistic safety margin in a form of load coefficient γ f and material coefficient γ m. Calculations of the bearing capacity of soil were made for pad foundations of sizes = 2 m and = 3 m and = 1.5 m and = 2.0 m and for strip foundation of a size of x = 2.0 x 14.0 m at a depth D = 1.0 m. It was assumed that there is a layer of cohesive soil of liquidity index, I = 0.15 or of I = 0.42 and of a thickness h 2 directly under foundations. To calculate soil bearing resistance acc. to PN-- 03020:1981P, characteristic shear strength parameters were adopted from nomographs given in the norm. Polish Norm distinguishes four types of soils marked A,, C and D: A over-consolidated moraine soils, over-consolidated soils and moraine normally consolidated soils, D clays of I P > 30%, regardless of origin. To calculate bearing resistance acc. to Eurocode 7, characteristic shear strength parameters, c and c u were adopted from nomographs in Figures 1, 2 and 3. Values of these parameters are corrected compared to those given in PISARCZYK, RYMSZA [1993] and KOSTRZEWSKI [1980]. The characteristic values of undrained cohesion c u was calculated based on the values of shear strength of Pleistocen soils τ f [KOSTRZEWSKI 1980], and correction factor μ. The μ depends on plasticity index, I P [AZZOUZ et al. 1983]. ' C' 28 26 24 22 20 18 16 14 12 10 0,0 0.0 0.1 0,1 0.2 0,2 0,3 0.3 0.4 0,4 0,5 0.5 0.6 0,6 I Fig. 1. Proposed effective friction angle vs. liquidity index for ultimate bearing resistance calculation acc. to Eurocode 7; source: own study 60 55 50 45 40 35 30 25 20 15 0,0 0.0 0,1 0.1 0,2 0.2 0,3 0.3 0,4 0.4 0,5 0.5 0,6 0.6 I Fig. 2. Proposed effective cohesion c vs. liquidity index for ultimate bearing resistance calculation acc. to Eurocode 7; source: own study A D D A

Comparison of shallow foundation design using Eurocode 7 and Polish Standard 59 Cu 300 280 260 240 220 200 180 160 140 120 100 80 60 40 0,0 0.0 0.1 0,1 0,2 0.2 0,3 0.3 0,4 0.4 0,5 0.5 0.6 0,6 Fig. 3. Proposed undrained shear strength c u vs. liquidity index for ultimate bearing resistance calculation acc. to Eurocode 7; source: own study I A D To compare the resistance for pad and strip foundations calculated acc. to PN--03020:1981P and PN- EN 1997-1, a reduction coefficient α = 0.87 was introduced to account for higher load coefficients used in PN-EN 1997-1:2008 [WYSOKIŃSKI et al. 2011]. earing resistance was calculated for 3 types of soils A, and D. Parameters, c and c u corresponding to soils of the liquidity index I = 0.15 or 0.42 were adopted for calculations. Soil resistance parameters used in calculations are set up in Table 1. ANAYSIS OF COMPUTATIONA RESUTS Results of performed calculations are set up in Tables 2 3. Figure 4 present a comparison of calculated values of ultimate bearing resistance calculated acc. to Eurocode 7 and PN--03020: 1981P. Table 1. Proposed characteristic parameters used for computing ultimate bearing resistance Class of soil u * iquidity index I 0.15 0.42 0.15 0.42 0.15 0.42 c u * u * c u * A 22.4 41.7 17.7 30.5 22.5 40.0 19.5 32.0 205 135 19.2 33.4 14.2 24.1 20.5 32.0 17.5 22.0 145 84 D 11.0 51.7 7.4 38.7 15.0 45.0 12.0 35.0 125 78 * Acc. to PN--03020:1981P (asterisk is given to distinguish the values of shear strength in undrained conditions c u. Source: own study., c' ' c' c u c u Table 2. earing resistance calculated acc. to PN--03020: 1981P and Eurocode 7 for soils of I = 0.15 and I = 0.42 for long-term design situation PN--03020:1981P PN-EN 1997-1:2008P 0.9m Q fn (kn)* R d (kn)* Genetic type of soil A D A D I = 0.15 1.5 2.0 m 2 360.4 1 630.2 1 387.1 2 213.3 1 579.0 1 363.3 2.0 3.0 m 4 642.4 3 197.7 2 708.1 4 367.4 3 120.7 2 681.3 2.0 14.0 m 1 191.0 809.7 708.0 1 227.9 886.1 772.0 I = 0.42 1.5 2.0 m 1 387.2 941.0 902.0 1 344.2 938.7 892.6 2.0 3.0 m 2 715.7 1 835.6 1 757.0 2 652.6 1 859.2 1 757.4 2.0 14.0 m 682.9 454.4 453.9 757.9 536.2 512.4 * Strip foundation (kn m 1 ). Source: own study. In all analysed cases the values of ultimate bearing capacity for pad foundations calculated acc. to Eurocode 7 and PN--03020:1981P were comparable. The ratio of respective values was from 0.94 to 1.01 for long-term computational situation and from 0.97 to 1.09 for short-term computational situation. Conditions for the long-term situation are decisive for bearing capacity of the soil. Ultimate bearing capacity for strip foundations calculated acc. to Eurocode 7 was in all cases higher than that calculated acc. to PN--03020:1981P. The ratio was from 1.03 to 1.18 for long-term situation Table 3. earing resistance calculated acc. to PN--03020: 1981P and Eurocode 7 for soils of I = 0.15 and I = 0.42 for short-term design situation PN--03020:1981P PN-EN 1997-1:2008P 0.9m Q fn [kn]* R d [kn]* Genetic type of soil A D A D I = 0.15 1.5 2.0 m 2 360.4 1 630.2 1 387.1 2 298.9 1 630.6 1 416.4 2.0 3.0 m 4 642.4 3 197.7 2 708.1 4 510.0 3 250.4 2 793.6 2.0 14.0 m 1 191.0 809.7 708.0 1 373.5 985.7 847.6 I = 0.42 1.5 2.0 m 1 387.2 941.0 902.0 1 526.1 964.8 899.0 2.0 3.0 m 2 715.7 1 835.6 1 757.0 3 011.0 1 903.0 1 772.2 2.0 14.0 m 682.9 454.4 453.9 913.3 578.2 538.8 * Strip foundation (kn m 1 ). Source: own study. and from 1.15 to 1.33 for short-term situation. As in the case of pad foundations, the conditions for longterm situation are decisive for bearing capacity of the soil. Significant differences in the values for strip foundations calculated acc. to both norms resulted from the values of adopted shape coefficients. Figure 5 show the relationship between shape coefficient and the width to length ratio of the foundation and the internal friction angle. Presented graphs indicate that the proportions of shape coefficients calculated acc. to PN and EC 7 depend on the : ratio.

60 A. OCHAWA, A. ZAWASKI a) b) c) Fig. 4. Comparison of the values of bearing resistance of soil calculated acc. to Eurocode 7 and Polish Norm: a) soils of the type A, b) soils of the type, c) soils of the type D; source: own study

Comparison of shallow foundation design using Eurocode 7 and Polish Standard 61 a) f ; fd, sq D s q 1,8 b) f ; fd, sc 1.6 1,6 1,5 1.4 1,4 c s1,3 c 1.2 1,2 1,1 2,6 2.4 2,4 2,2 2.0 2,0 1.6 1,6 1,4 1.2 1,2 1,0 PN : f PN: D f D 1 11.5 1, 5 ' EC -7: s 1 q sin EC 7 : 1 sq sin ' PN EC-7 0.8 0,8 0,1 0.1 0,2 0.2 0,3 0.3 0,4 0.4 0,5 0.5 0,6 0.6 0,7 0.7 0,8 0.8 0,9 0.9 1,0 1.0 ' PN : f PN: c 1 f0.3 c 1 0, 3 sq Ns q N 1 q 1 EC 7 : sc sc Nq 1 EC-7: Nq 1 s c 1 0, 2 sc 1 0.2 EC-7 EC-7 ' 0 26 1.0 1,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 PN EC-7 (Undrained conditions) ' 0 11 Rys. 5. Shape coefficient values: a) f D and s q, b) f c and s c in relation to the foundation width to length ratio used in both norms; source: own study Assuming the correctness of adopted geotechnical parameters of the soil and shape coefficients from EC 7, the comparability of bearing capacities of pad foundations calculated acc. to both norms may indicate that safety margin drawn from PN--03020: 1981P for strip foundations is too large. CONCUSIONS φ = 26 φ = ' o 26 26 φ = ' o 11 11 φ = 11 1. Presented modification of soil geotechnical parameters known from the literature enables their use in calculations of bearing resistance of soils acc. to Eurocode 7 and to obtain results comparable with those calculated acc. to PN--03020:1981P. 2. earing capacities of pad foundations calculated acc. to EC 7 and PN--03020:1981P are comparable. 3. earing capacities of strip foundations calculated acc. to EC 7 were in all analysed cases larger than those calculated acc. to PN--03020:1981P. 4. Presented proposal is based on a low number of cases and it is recommended to perform further analyses on more cases. REFERENCES AZZOUZ A.S., AIGH M.M., ADD C.C. 1983. Corrected field vane strength for embankment design. Journal of Geotechnical Engineering. Vol. 109. Iss. 5 p. 730 734. GAAS P., KIZIEWICZ D. 2009. Ocena nośności podłoża pod stopą fundamentową według Eurokodu 7 oraz PN-81/- 03020. W: Problemy geotechniczne i środowiskowe z uwzględnieniem podłoży ekspansywnych [The bearing capacity evaluation of pad foundation based on Eurocode 7 and PN-81/-03020. In: Expansive soils and their influence on geotechnical properties of subsoil and environmental conditions]. Materiały XV Krajowej Konferencji Mechaniki Gruntów i Inżynierii Geotechnicznej. ydgoszcz 7 10.07.2009. ydgoszcz. Wydaw. Uczeln. UTP p. 575 582. GARWACKA-PIÓRKOWSKA S. 2011. Porównanie obliczeniowych nośności jednostkowych gruntów pod ławami i stopami fundamentowymi według PN-EN 1997-1 i PN-- 03020:1981 [The comparison of computational unit load capacity of grounds under concrete strip footing and spot footing according to PN-EN 1997-1 and PN--03020: 1981]. Inżynieria i udownictwo. Nr 1. Warszawa. PZIT p. 17 21. GOSK W. 2010. Nośność podłoża gruntowego pod ławą fundamentową według Eurokodu 7 oraz PN-81/-03020 [The bearing capacity of subsoil under continuous foundation based on Eurocode 7 and PN-81/-03020]. udownictwo i Inżynieria Środowiska. Vol. 1. Nr 2 p. 127 130. GRAOWSKA-OSZEWSKA. (ed.) 1990. Metody badań gruntów spoistych [Methods for determining properties of clayey soils]. Warszawa. Wydaw. Geol. ISN 83-220- 0315-3 pp. 387. KIZIEWICZ D. 2009. Analiza nośności podłoża z gruntów spoistych obciążonego mimośrodowo fundamentem bezpośrednim wg Eurokodu 7 rozwiązanie przykładu 2.2 ETC10 [earing capacity analysis of cohesive soils subjected to inclined load from shallow foundation according to Eurocode 7 solution of design example 2.2 ETC 10]. Przegląd Naukowy Inżynieria i Kształtowanie Środowiska. Vol. 18(4). Nr 46 p. 67 76. KŁOSIŃSKI. 2013. Ocena i przyszłość Eurokodu 7 Projektowanie geotechniczne [Evaluation and future of the Eurocode 7 Geotechnical design]. Przegląd Naukowy Inżynieria i Kształtowanie Środowiska. Vol. 22(2). Nr 60 p. 222 235. KOSTRZEWSKI W. 1980. Mechanika gruntów. Parametry geotechniczne gruntów budowlanych oraz metody ich wyznaczania [Soil mechanics. Geotechnical parameters and methods of testing]. Warszawa. PWN. ISN 8301020 44X pp. 284. KOTICKI W. 2005. Projektowanie posadowień bezpośrednich w ujęciu Eurokodu 7 [Design of shallow foundation according to Eurocode 7]. XX Ogólnopolska Konferencja Warsztat Pracy Projektanta Konstrukcji, Wisła Ustroń. Kraków. PZIT p. 71 90. KOTICKI W. 2009. Projektowanie posadowień bezpośrednich w EC 7 [Design of shallow foundation according in EC 7]. XXIV Ogólnopolska Konferencja Warsztat Pracy Projektanta Konstrukcji. Wisła. Kraków. PZIT p. 205 245. KUCHER A., KUSZYK R. 2006. Posadowienie bezpośrednie w ujęciu EN 1997-1 Eurocode 7 [New method of foundation analysis according to EN 1997-1 Eurocode 7]. Inżynieria i udownictwo. Nr 12. Warszawa. PZIT p. 661 663.

62 A. OCHAWA, A. ZAWASKI OCHAWA A., ZAWASKI A. 2014. Uwagi na temat parametrów wytrzymałościowych gruntów spoistych do obliczeń nośności podłoża gruntowego według Eurokodu 7 [Some remarks on the shear strength parameters of cohesive soils to be used for computing bearing capacity according acc. to Eurocode 7]. Inżynieria Morska i Geotechnika. In print. PIECZYRAK J. 2006. Nośność graniczna podłoża gruntowego według PN-81/-03020 i Eurokodu 7 [Ultimate bearing capacity of subsoil according to Polish Standard PN- 81/-03020 and Eurocode 7]. XIV Krajowa Konferencja Mechaniki Gruntów i Inżynierii Geotechnicznej, iałystok Augustów. Zeszyty Naukowe Politechniki iałostockiej udownictwo. Vol. 28(2) p. 197 211. PISARCZYK S., RYMSZA. 1993. adania laboratoryjne i polowe gruntów [aboratory and field testing of soil]. Warszawa. Ofic. Wydaw. PW pp. 489. PN-EN 1997-1:2008P, PN-EN 1997-1:2008/NA:2011P. Projektowanie geotechniczne część 1: Zasady ogólne. [Geotechnical design Part 1: General rules]. PN--03020:1981P. Posadowienie bezpośrednie budowli. Obliczenia statyczne i projektowanie [uilding soils. Foundation bases. Static calculation and design]. SUEWSKA M., KONOPKA R. 2013. Analiza nośności granicznej podłoża pod stopą fundamentową według PN-EN 1997-1 (2008) i PN-81/-03020 (1981) [Assessment of bearing capacity of pad foundation based on PN-EN 1997-1 (2008) and PN-81/-03020 (1981)]. Przegląd Naukowy Inżynieria i Kształtowanie Środowiska. Vol. 22 (2). Nr 60 p. 188 207. VOGT N., SCHUPPENER., WEISSENACH A., GAJEWSKA., KŁOSIŃSKI. 2006. Podejścia obliczeniowe stosowane w Niemczech w projektowaniu geotechnicznym według Eurokodu 7-1 [Design approaches of EC 7-1 for geotechnical verifications used in Germany]. Inżynieria i udownictwo. Nr 6. Warszawa. PZIT p. 326 330. WYSOKIŃSKI. 2005. Podstawy projektowania geotechnicznego [asis of geotechnical design]. XX Ogólnopolska Konferencja Warsztat Pracy Projektanta Konstrukcji. Wisła Ustroń. Kraków. PZIT p. 35 70. WYSOKIŃSKI., KOTICKI W., GODEWSKI T. 2011. Projektowanie geotechniczne według Eurokodu 7. Poradnik [Geotechnical design according to Eurocode 7. Guide]. Warszawa. Dział Wydaw. IT. ISN 978-83-249-4831-4 pp. 286. Andrzej OCHAWA, Andrzej ZAWASKI Porównanie projektowania fundamentów bezpośrednich na podstawie Eurokodu 7 i Polskiej Normy STRESZCZENIE Słowa kluczowe: Eurokod 7, grunty spoiste, fundamenty bezpośrednie, nośność podłoża gruntowego, projektowanie geotechniczne Wykonano obliczenia nośności podłoża spoistego na podstawie PN--03020:1981P i Eurokodu 7. Do obliczeń wg Eurokodu 7 przyjęto zmodyfikowane przez autorów parametry wytrzymałościowe gruntu spoistego: wytrzymałość na ścinanie w warunkach bez odpływu c u, efektywną spójność c' i efektywny kąt tarcia wewnętrznego '. Wartości tych parametrów zależą od parametru wiodącego stopnia plastyczności I. Wykonano obliczenia nośności podłoża dla dwóch stóp fundamentowych o wymiarach = 2,0 3,0 m i 1,5 2,0 m oraz jednej ławy fundamentowej 2,0 14,0 m. Obliczoną nośność podłoża wg EC 7 zredukowano mnożąc przez współczynnik α = 0,87 celem uwzględnienia stosowanych różnych współczynników obciążeń w Polskich Normach i Eurokodach. Przeprowadzone analizy obliczeń wykazały porównywalne nośności podłoża niezależnie od przyjętej normy EC 7 i PN dla stóp fundamentowych. Natomiast we wszystkich analizowanych przypadkach nośność ław fundamentowych obliczona wg Eurokodu 7 była większa od obliczonej wg PN- -03020:1981P. Przyczyną są różnice w wartościach i sposobie uwzględniania częściowych współczynników bezpieczeństwa oraz różnice w wartościach współczynników kształtu uwzględnianych we wzorze na całkowitą wartość oporu granicznego podłoża gruntowego.