Noise Emitted by SKM Trains in Gdansk



Podobne dokumenty
Zakopane, plan miasta: Skala ok. 1: = City map (Polish Edition)

Has the heat wave frequency or intensity changed in Poland since 1950?

Cracow University of Economics Poland

The Overview of Civilian Applications of Airborne SAR Systems

Country fact sheet. Noise in Europe overview of policy-related data. Poland

Wykaz linii kolejowych, które są wyposażone w urządzenia systemu ETCS

Wykaz linii kolejowych, które są wyposażone w urzadzenia systemu ETCS

SPITSBERGEN HORNSUND

EVALUATION OF THE EFFICIENCY OF AN NOISE BARRIER ALONG THE RAILWAY LINE RZESZOW-MEDYKA

Machine Learning for Data Science (CS4786) Lecture 11. Spectral Embedding + Clustering

SPITSBERGEN HORNSUND

Budynki i zabudowania na terenie (T/N) Buildings / other constructions on site (Y/N)

SPITSBERGEN HORNSUND

Helena Boguta, klasa 8W, rok szkolny 2018/2019

Patients price acceptance SELECTED FINDINGS

SPITSBERGEN HORNSUND

Fig 5 Spectrograms of the original signal (top) extracted shaft-related GAD components (middle) and

BULLETIN 2 II TRAINING CAMP POLISH OPEN MTBO CHAMPIONSHIPS MICHAŁOWO TRAINING CAMP WORLD MTB ORIENTEERING CHAMPIONSHIPS

SPITSBERGEN HORNSUND

DM-ML, DM-FL. Auxiliary Equipment and Accessories. Damper Drives. Dimensions. Descritpion

Cracow University of Economics Poland. Overview. Sources of Real GDP per Capita Growth: Polish Regional-Macroeconomic Dimensions

SPITSBERGEN HORNSUND

Galeria Handlowa Starogard Gdański


PORTS AS LOGISTICS CENTERS FOR CONSTRUCTION AND OPERATION OF THE OFFSHORE WIND FARMS - CASE OF SASSNITZ

Przewody do linii napowietrznych Przewody z drutów okrągłych skręconych współosiowo

Instructions for student teams

Noise prevention policy in Poland. Where are we?

you see decision. oznacza to, Whenever kiedy widzisz biznes, someone once made Za każdym razem, który odnosi sukces,

SPITSBERGEN HORNSUND

OPTYMALIZACJA PUBLICZNEGO TRANSPORTU ZBIOROWEGO W GMINIE ŚRODA WIELKOPOLSKA

SPITSBERGEN HORNSUND

MIL SUP 21/15 (ENR 5) Obowiązuje od / Effective from 08 JUN 2015 Obowiązuje do / Effective to 19 JUN 2015

4. EKSPLOATACJA UKŁADU NAPĘD ZWROTNICOWY ROZJAZD. DEFINICJA SIŁ W UKŁADZIE Siła nastawcza Siła trzymania

DOI: / /32/37

SPITSBERGEN HORNSUND


TYRE PYROLYSIS. REDUXCO GENERAL DISTRIBUTOR :: ::


BIOPHYSICS. Politechnika Łódzka, ul. Żeromskiego 116, Łódź, tel. (042)

PARAMETRY TECHNICZNE DEKLAROWANE PRZEZ PRODUCENTA POTWIERDZONE BADANIAMI / RATINGS ASSIGNED BY THE MANUFACTURER AND PROVED BY TESTS

Extraclass. Football Men. Season 2009/10 - Autumn round

Warszawa Al. Jerozolimskich przy ul. Badylarskiej

Regionalny Dyrektor Ochrony Środowiska ul. 28 czerwca 1956 Poznań

Wojewodztwo Koszalinskie: Obiekty i walory krajoznawcze (Inwentaryzacja krajoznawcza Polski) (Polish Edition)

OCENA MECHANIZMÓW POWSTAWANIA PĘKNIĘĆ WĄTROBY W URAZACH DECELERACYJNYCH ZE SZCZEGÓLNYM UWZGLĘDNIENIEM ROLI WIĘZADEŁ WĄTROBY

MaPlan Sp. z O.O. Click here if your download doesn"t start automatically

Network Services for Spatial Data in European Geo-Portals and their Compliance with ISO and OGC Standards

What our clients think about us? A summary od survey results

PODZIAŁ SEKTOROWY OBSZARU KONTROLOWANEGO ACC W FIR WARSZAWA SECTORS OF ACC CONTROLLED AREA WITHIN WARSZAWA FIR

SEGRO BUSINESS PARK WARSAW

PRODUCTION HALL OFFER

Ekonomiczne i społeczno-demograficzne czynniki zgonów osób w wieku produkcyjnym w Polsce w latach

Wydział Fizyki, Astronomii i Informatyki Stosowanej Uniwersytet Mikołaja Kopernika w Toruniu

Rozpoznawanie twarzy metodą PCA Michał Bereta 1. Testowanie statystycznej istotności różnic między jakością klasyfikatorów

EGARA Adam Małyszko FORS. POLAND - KRAKÓW r

Karpacz, plan miasta 1:10 000: Panorama Karkonoszy, mapa szlakow turystycznych (Polish Edition)

STAŁE TRASY LOTNICTWA WOJSKOWEGO (MRT) MILITARY ROUTES (MRT)

Krytyczne czynniki sukcesu w zarządzaniu projektami

VFR SUP 37/11 (VFR ENR) Obowiązuje od / Effective from 01 SEP 2011 Obowiązuje do / Effective to 29 NOV 2011 EST

POLITECHNIKA ŚLĄSKA INSTYTUT AUTOMATYKI ZAKŁAD SYSTEMÓW POMIAROWYCH

Stargard Szczecinski i okolice (Polish Edition)

WYKAZ PRÓB / SUMMARY OF TESTS. mgr ing. Janusz Bandel

Sustainable mobility: strategic challenge for Polish cities on the example of city of Gdynia

Camspot 4.4 Camspot 4.5

Nazwa projektu: Kreatywni i innowacyjni uczniowie konkurencyjni na rynku pracy

ARKOŃSKA BUSINESS PARK A1

Weronika Mysliwiec, klasa 8W, rok szkolny 2018/2019

European Crime Prevention Award (ECPA) Annex I - new version 2014

SPITSBERGEN HORNSUND

Zarządzanie sieciami telekomunikacyjnymi

Streszczenie rozprawy doktorskiej

G14L LPG toroidal tank

'11"N '08"E '57"N '21"E '57"N '21"E '47"N '14"E

SSW1.1, HFW Fry #20, Zeno #25 Benchmark: Qtr.1. Fry #65, Zeno #67. like

OpenPoland.net API Documentation

PODZIAŁ SEKTOROWY OBSZARU KONTROLOWANEGO ACC W FIR WARSZAWA SECTORS OF ACC CONTROLLED AREA WITHIN WARSZAWA FIR

Tychy, plan miasta: Skala 1: (Polish Edition)

Knovel Math: Jakość produktu

ELECTRIC AND MAGNETIC FIELDS NEAR NEW POWER TRANSMISSION LINES POLA ELEKTRYCZNE I MAGNETYCZNE WOKÓŁ NOWYCH LINII ELEKTROENERGETYCZNYCH

Employment. Number of employees employed on a contract of employment by gender in Company

Unit of Social Gerontology, Institute of Labour and Social Studies ageing and its consequences for society

PN-ISO 10843:2002/AC1

Sargent Opens Sonairte Farmers' Market

Pomiary hydrometryczne w zlewni rzek

RADIO DISTURBANCE Zakłócenia radioelektryczne

SPITSBERGEN HORNSUND

Revenue Maximization. Sept. 25, 2018

WOJSKOWE TRASY LOTÓW (MRT) NA MAŁYCH WYSOKOŚCIACH LOW FLYING MILITARY TRAINING ROUTES (MRT)

MIL SUP 60/16 (MIL ENR 5) Obowiązuje od / Effective from 11 AUG 2016 Obowiązuje do / Effective to 15 AUG 2016

PERSPEKTYWY ZRÓWNOWAŻONEGO ROZWOJU TRANSPORTU DROGOWEGO W POLSCE DO 2030 ROKU

Test sprawdzający znajomość języka angielskiego

Konsorcjum Śląskich Uczelni Publicznych

Katowice, plan miasta: Skala 1: = City map = Stadtplan (Polish Edition)

Planowanie zrównoważonego transportu miejskiego w Polsce. Sustainable Urban Mobility Planning Poland. Wprowadzenie. Introduction

No matter how much you have, it matters how much you need

AKADEMIA MORSKA W SZCZECINIE WYDZIAŁ MECHANICZNY ROZPRAWA DOKTORSKA. mgr inż. Piotr Smurawski

THE INVESTMENT AREAS - BYTOM, LEŚNA STREET TERENY INWESTYCYJNE - BYTOM, ULICA LEŚNA

Awareness campaign Safe rail-road level crossing "Stop and Live!"

Miedzy legenda a historia: Szlakiem piastowskim z Poznania do Gniezna (Biblioteka Kroniki Wielkopolski) (Polish Edition)

Transkrypt:

Wojciech Owczarzak 1, Sławomir Sommer 2, Piotr Mioduszewski Gdansk University of Technology 3 Noise Emitted by SKM Trains in Gdansk Introduction The city of Gdansk is the center of agglomeration, which counts 460 427 inhabitants and covers an area of approximately 261.96 km 2. It is the fourth largest metropolitan area in Poland [1], [2]. In such a big city public transport play a key role, which at the current number of cars and insufficient road infrastructure is a huge facilitation of access to workplaces, universities, schools and recreation places. SKM is one of the major carriers in the city, next to trams and buses. In 2013 about 35 million passengers used SKM services [3]. SKM manages the railway line No. 250, which has a total length of 31 km (section Gdansk Rumia). According to the classification of transport it is a first-class line, dedicated for passenger transport only, double-track with a speed limit of 70 km/h [4]. SKM trains runs with variable frequency depending on a time. Every 7 minutes (6.00 9.15 and 13.45 18.45) and 15 minutes (9.45 13.45) in the daytime, during evenings and nights there are longer intervals (every 30, 60, 90 or 120 minutes) [5]. Such a large volume of rail vehicles is associated with audible noise emission. What is more important, SKM line runs through the central part of the city and therefore it runs in the vicinity of residential areas and recreational facilities. To measure noise emissions were located four measurement points along the track. Measurements were performed in daytime (6.00 18.00) when rail traffic is very high. Research was conducted in accordance with the guidelines contained in the Regulation of the Minister of Environment of June 16th 2011 dealing with the requirements for conducting measurements of the levels of substances or energy in the environment by administrator of road, railway, tramway line, airport or port [6]. The diagram below shows the shape of the line operated by SKM in Gdansk, together with the measuring points (Fig.1). Purpose and research methodology The aim of this research was to measure an actual level of noise generated by SKM trains running through the city of Gdańsk. As a part of a single measurement equivalent sound level (Leq) was acquired. Individual acoustic events were measured by sonometer Bruel&Kjar 2250. Calibration was performed using a sound level meter calibrator Bruel&Kjaer 4231. The microphone was positioned on a tripod at a height of 4 meters above the ground level and in a predetermined locations in the vicinity of the tracks used by SKM trains (see at Fig.1). Due to the terrain shape, the amount of open space and safety considerations, not all measurement points were located at the recommended distance. In order to recalculate sound level values for a predefined distance of 20 m the equation describing the propagation of noise from a moving source was used: LL IIII = LL IIIIII 10llll rr rr pp (1) where: L Ir level acoustic source at a measured distance r (db) L Irp level acoustic sources within recommended distance r p (db) 1 Mgr inż. W. Owczarzak, doctoral student, Gdansk University of Technology, Department of Mechanical Engineering, Gdańsk, Poland 2 Mgr inż. S. Sommer, doctoral student, Gdansk University of Technology, Department of Mechanical Engineering, Gdańsk, Poland 3 Dr inż. P. Mioduszewski, adjunct, Gdansk University of Technology, Department of Mechanical Engineering, Gdańsk, Poland 4771

r sound source distance (m) r p sound source recommended distance (m) Fig.1. Diagram of SKM network in Gdansk with measuring points (red dots-stops; 1,2,3,4 - measuring points) Source: http://www.skm.pkp.pl/o-nas/mapa-trasy-skm/ Measurement points Measurements were performed at four locations given below: The neighbourhood of SKM Gdansk Stocznia platform (1) The first measurement point was located in the vicinity of SKM Gdańsk Stocznia platform(54.362694 N, 18.643109 E). The photo showing the described location was presented in Fig.2. The microphone was located within the following distances from the railheads: 46 m (for vehicles coming towards Gdynia Main Station) 42.5 m (for vehicles coming towards Gdansk Main Station) These distances were chosen because of the lack of other possible locations in the area that would meet safety requirements, and were free from external noise sources that could disturb measurements. 4772

Fig. 2. Location of the measuring point in the vicinity of SKM Gdansk Stocznia platform The neighbourhood of SKM Gdansk Wrzeszcz platform (2) The second measuring point was located in the vicinity of the SKM Gdańsk Wrzeszcz platform (54.385038 N, 18.598721 E). The photo showing the described location is presented in Fig. 3. The microphone was located within the following distances from the railheads: 20 m (for vehicles coming towards Gdynia Main Station) 25 m (for vehicles coming towards Gdansk Main Station) Fig. 3. Location of measuring point in the vicinity of SKM Gdansk Wrzeszcz platform The neighbourhood of SKM Gdansk Przymorze platform (3) The third measuring point was located in the vicinity of the SKM Gdańsk Przymorze platform (54.396964 N, 18.581488 E). The photo showing the described location is presented in Fig. 4.The microphone was located within the following distances from the railheads: 15 m (for vehicles coming towards Gdynia Main Station) 20 m (for vehicles coming towards Gdansk Main Station) 4773

Fig. 4. Location of measuring point in the vicinity of SKM Gdansk Przymorze platform source: The Author s material The neighbourhood of SKM Gdansk Oliwa platform (4) The last fourth measurement point was located in the vicinity of the SKM Gdańsk Oliwa platform (54.405031 N, 18.574003 E). The photo showing the described location is presented in Fig. 5. The microphone was located within the following distances from the railhead: 14 m (for vehicles coming towards Gdynia Main Station) 10 m (for vehicles coming towards Gdansk Main Station) Fig. 5. Location of measuring point in the vicinity of of SKM Gdansk Przymorze platform Meteorological data Meteorological data obtained from Agency of Regional Air Quality Monitoring in the Gdańsk metropolitan area. Data is shown in the table below: Location Temperature ( C) Wind speed (m/s) Table1. Meteorological data Pressure (hpa) Humidity (%) Rainfall 1 15.0 18.8 1.0 1.5 1004.9 1005.4 32.3 59.5 No 2 8.9 9.0 1.8 2.0 1018.7 1018.9 53.7 55.6 No 3 8.2 8.6 1.7 1.8 1017.7 1018.5 51.9 52.4 No 4 12.1 13.6 1.8 2.9 1014.7 1016.0 60.4 65.3 No Source: Meteorological data obtained from Agency of Regional Air Quality Monitoring in the Gdańsk metropolitan area 4774

Results and Discussion According to the regulation of the Minister of Environment of October 1th 2012, the allowed sound level is 65 db for all measurement points and they were much above the limits for all measurement points. Measured noise levels were in the range of 69.0 db to 76,8 db. The highest values were observed in location no.1 in spite of the fact that speed of trains was the lowest at that location. The lowest levels of noise emission were noted for location no. 2. This can be a result of relative low speed of trains on this section. In location no. 3 the authors observed a typical noise levels emission for trains moving with that speed. In the last location (no. 4), comparatively to location no.1, levels of noise emission are much higher than would have resulted from the train speed. Table 2. Results of measurements of noise levels emitted by SKM trains Location Leq (db) (calculated for 20 m) Number of tested vehicles Average speed (km/h) (standard deviation) Gdynia direction 70.8 6 9.1 (0.3) 1 Gdańsk direction 76.7 6 16.1 (1.1) Gdynia direction 69.0 6 41.4 (1.5) 2 Gdańsk direction 69.0 8 44.1 (2.0) Gdynia direction 74.7 5 51.2 (1.7) 3 Gdańsk direction 72.7 7 49.8 (1.9) Gdynia direction 76.6 7 33.6 (1.7) 4 Gdańsk direction 74.0 9 36.5 (1.8) Summary 54 Conclusions The measured noise levels at all test points were about from about 4 up to about 12 db above limits. It can be a nuisance for people living near the SKM tracks. This problem was partially solved by placing noise barriers in the area extensively exposed to noise. This was a necessary compromise between an efficient public transport, and its negative impact on the environment. Abstract High intensity traffic of SKM trains in Gdansk carries a significant level of noise emission. SKM line runs through the central part of the city and therefore in the vicinity of residential areas and recreational facilities. This research was planned and performed to find out what was the real noise emission of SKM trains and to determine whether the measurement noise values are within allowed limits. Individual acoustic events were measured using the sound level meter and the average of noise levels was calculated. The measured noise levels at all test points were about 4 12 db above the allowed noise limits. Keywords: Railway noise, railway transportation 4775

HAŁAS EMITOWANY PRZEZ POCIĄGI SKM W GDAŃSKU Streszczenie Wysokie natężenie ruchu pociągów SKM w Gdańsku wiąże się ze znacznym poziomem emisji hałasu. Linia SKM przebiega przez centralną część miasta, a więc w pobliżu obszarów mieszkalnych i rekreacyjnych. Badanie zostało zaplanowane i przeprowadzone tak, aby dowiedzieć się, jaki był prawdziwy poziom emisji hałasu pociągów SKM i określić, czy wartości zmierzonego hałasu mieszczą się w dozwolonych granicach. Poszczególne zdarzenia akustyczne zostały zmierzone za pomocą sonometru i został obliczony średni poziom hałasu. Zmierzone poziomy hałasu we wszystkich punktach pomiarowych były o około 4 12 db wyższe od dozwolonych limitów. Słowa kluczowe: pociągi SKM, poziom emisji hałasu, transport kolejowy References [1] Rocznik demograficzny, Główny Urząd Statystyczny, Warszawa, 2013 [2] Powierzchnia i ludność w przekroju terytorialnym w 2013 r., Główny Urząd Statystyczny, Warszawa, 2013 [3] http://www.rynekkolejowy.pl/50662/kolej_traci_pasazerow_ponad_16_mln_w_przewozach_regiona lnych_ponad_4_5_mln_w_pkp_intercity.htm [4] http://www.skm.pkp.pl/infrastruktura/parametry-techniczno-eksploatacyjne/ [5] http://www.skm.pkp.pl [6] Rozporządzenie Ministra Środowiska z dnia 16 czerwca 2011 r. w sprawie wymagań w zakresie prowadzenia pomiarów poziomów substancji lub energii w środowisku przez zarządzającego drogą, linią kolejową, linią tramwajową, lotniskiem lub portem 9Dz.U. 2011 nr 140 poz. 824) Dane zawarte w niniejszej publikacji zostały udostępnione nieodpłatnie i pozostają własnością Fundacji Agencja Regionalnego Monitoringu Atmosfery Aglomeracji Gdańskiej ARMAAG. 4776