AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 2 of (Stron) 9 Following requirements should be taken into account in the case of making use of Test Report and giving information about the tests performed by TEST LABORATORY : - The test results presented in this report relate only to the item(s) tested. - This report shall not be reproduced except in full. It should not be used for advertising and promotion purposes in a manner or form which can lead to misunderstanding. - The Test Report issued by TEST LABORATORY in no way constitues or implies the product approval by any certification body or any other body. - Any information about tests performed by TEST LABORATORY and about its accreditation by (PCA) should be agreed with LABORATORY management to avoid erroneous qualification of accreditation range Warunki wykorzystania sprawozdania z badań oraz informowania o fakcie przeprowadzenia badań w Laboratorium Badawczym : - Wynik badania dotyczy obiektów poddanych badaniu - Sprawozdanie z badań moŝe być powielone przez Zleceniodawcę tylko w całości. Nie moŝe być wykorzystane w celech reklamowych lub promocyjnych w sposób i w formie mogącej wprowadzić kogokolwiek w błąd. - Sprawozdanie z badań wykonywanych przez Laboratorium Badawcze nie oznacza ani nie sugeruje aprobaty wyrobu przez jednostkę certyfikujacą wyroby bądź jakąkolwiek inną jednostkę organizacyjną. - W przypadku informowania o korzystaniu z usług Laboratorium Badawczego i potrzeby podkreślenia, Ŝe Laboratorium jest akredytowane przez Polskie Centrum Akredytacji (PCA) treść takiej informacji powinna być uzgadniana z Laboratorium w celu naleŝytego określenia zakresu akredytacji udzielonej Laboratorium przez PCA.
AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 3 of (Stron) 9 Copy of marking plate Napisy i oznaczenia na obiekcie badań
AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 4 of (Stron) 9 Mains interference voltage Niesymetryczne napięcie zakłóceń na przewodach wejściowych zasilania Quasi-peak value 70 60 50 40 30 0,1 1 10 100 f [MHz] QP limit (poziom dop. quasi-szczytowy) AVG limit (poziom dop. średni) measured QP value (zakłócenia QP) Test instruments used:interference Meter Miernik zakłóceń : SMV 11, nr 1-316 UŜyta aparatura Artificial Mains Network [AMN, LISN] Sieć sztuczna: MN2050B, nr 1-234 Remarks: Uwagi Uncertainty of the method Niepewność metody 3 db. Recording level (offset) Poziom rejestracji 30 db. Measured value - below the limit. Zmierzone wartości nie przekraczają poziomu dopuszczalnego. Mains Voltage in Test Napięcie zasilania podczas próby: 230 VAC. Load: resistive ObciąŜenie: rezystancyjne: 0-15 W.
AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 5 of (Stron) 9 Mains interference voltage at the Power Input - quasi peak value Niesymetryczne napięcie zakłóceń na przewodach wejściowych zasilania - wartości quasi-szczytowe freq. [MHz] Measured Value; X1 X2 X3 X4 X5 Xsr Sn-1 Xsr+k Sn-1 Limit (Norma) Margin (Margines) 0,150 66,0 66,0 0,160 38,0 65,5 27,5 0,170 31,0 65,0 34,0 0,180 33,0 64,5 31,5 0,190 42,0 64,0 22,0 0,200 44,0 63,6 19,6 0,220 34,0 62,8 28,8 0,250 34,0 61,8 27,8 0,270 49,0 61,1 12,1 0,300 41,0 60,2 19,2 0,320 41,0 59,7 18,7 0,350 32,0 59,0 27,0 0,400 53,0 57,9 4,9 0,450 35,0 56,9 21,9 0,500 42,0 56,0 14,0 0,570 52,0 56,0 4,0 0,600 43,0 56,0 13,0 0,660 48,0 56,0 8,0 0,720 43,0 56,0 13,0 0,750 38,0 56,0 18,0 0,800 45,0 56,0 11,0 0,850 41,0 56,0 15,0 0,960 39,0 56,0 17,0 1,020 40,0 56,0 16,0 1,220 44,0 56,0 12,0 1,500 40,0 56,0 16,0 1,700 43,0 56,0 13,0 2,000 42,0 56,0 14,0 2,180 45,0 56,0 11,0 2,500 44,0 56,0 12,0 3,000 46,0 56,0 10,0 3,850 51,0 56,0 5,0 4,000 48,0 56,0 8,0 4,500 40,0 56,0 16,0 5,000 37,0 56,0 19,0 6,000 34,0 60,0 26,0 7,000 34,0 60,0 26,0 8,000 33,0 60,0 27,0 9,000 32,0 60,0 28,0 10,000 32,0 60,0 28,0 11,000 30,0 60,0 30,0 12,000 30,0 60,0 30,0 13,000 60,0 60,0 14,000 60,0 60,0 15,000 60,0 60,0 16,000 60,0 60,0 17,000 60,0 60,0 18,000 60,0 60,0 19,000 60,0 60,0 20,000 60,0 60,0 21,000 60,0 60,0 22,000 60,0 60,0 23,000 60,0 60,0 24,000 60,0 60,0 25,000 60,0 60,0 26,000 60,0 60,0 27,000 60,0 60,0 28,000 60,0 60,0 29,000 60,0 60,0 30,000 60,0 60,0 (Measured value = Wartość zmierzona)
AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 6 of (Stron) 9 Mains interference voltage at the Power Input - average value Niesymetryczne napięcie zakłóceń na przewodach wejściowych zasilania - wartości średnie freq. [MHz] Measured value; X1 X2 X3 X4 X5 Xsr Sn-1 Xsr+k Sn-1 Limit (Norma) Margin (Margines) 0,400 41,0 47,9 6,9 0,570 39,0 46,0 7,0 0,660 36,0 46,0 10,0 3,000 36,0 46,0 10,0 3,850 41,0 46,0 5,0 4,000 39,0 46,0 7,0 (Measured value = Wartość zmierzona)
AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 7 of (Stron) 9 Interference voltage at the Output (LOAD) Niesymetryczne napięcie zakłóceń na przewodach obciąŝenia Quasi-peak value 90 80 70 60 50 40 30 0,1 1 10 100 f [MHz] QP limit (poziom dop. quasi-szczytowy) AVG limit (poziom dop. średni) measured QP value (zakłócenia QP) Test instruments used: Interference Meter Miernik zakłóceń : SMV 11, nr 1-316 UŜyta aparatura Artificial Mains Network [AMN, LISN] Sieć sztuczna: MN2050B, nr 1-234 Remarks: Uwagi Probe sonda SLMZ-150/50, nr 2-316 Uncertainty of the method Niepewność metody 3 db. Recording level (offset) Poziom rejestracji 30 db. Measured value - below the limit. Zmierzone wartości nie przekraczają poziomu dopuszczalnego. Mains Voltage in Test Napięcie zasilania podczas próby: 230 VAC. Load: resistive ObciąŜenie: rezystancyjne: 0-15 W.
AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 8 of (Stron) 9 Interference voltage at the Output (LOAD) - quasi peak value Niesymetryczne napięcie zakłóceń na przewodach obciąŝenia - wartości quasi-szczytowe freq. [MHz] Measured Value; X1 X2 X3 X4 X5 Xsr Sn-1 Xsr+k Sn-1 Limit (Norma) Margin (Margines) 0,150 51,0 80,0 29,0 0,160 52,0 80,0 28,0 0,170 63,0 80,0 17,0 0,180 66,0 80,0 14,0 0,190 58,0 80,0 22,0 0,200 55,0 80,0 25,0 0,220 60,0 80,0 20,0 0,260 71,0 80,0 9,0 0,280 56,0 80,0 24,0 0,310 66,0 80,0 14,0 0,320 67,0 80,0 13,0 0,350 55,0 80,0 25,0 0,400 68,0 80,0 12,0 0,450 56,0 80,0 24,0 0,500 67,0 74,0 7,0 0,550 72,0 74,0 2,0 0,600 64,0 74,0 10,0 0,650 65,0 74,0 9,0 0,700 66,0 74,0 8,0 0,750 61,0 74,0 13,0 0,800 65,0 74,0 9,0 0,830 66,0 74,0 8,0 0,900 63,0 74,0 11,0 1,000 61,0 74,0 13,0 1,260 65,0 74,0 9,0 1,500 58,0 74,0 16,0 1,800 64,0 74,0 10,0 2,000 63,0 74,0 11,0 2,250 64,0 74,0 10,0 2,470 66,0 74,0 8,0 2,930 68,0 74,0 6,0 3,500 73,0 74,0 1,0 4,000 65,0 74,0 9,0 4,500 61,0 74,0 13,0 5,000 59,0 74,0 15,0 6,000 57,0 74,0 17,0 7,000 59,0 74,0 15,0 8,000 56,0 74,0 18,0 9,000 57,0 74,0 17,0 10,000 56,0 74,0 18,0 11,000 57,0 74,0 17,0 12,000 56,0 74,0 18,0 13,000 51,0 74,0 23,0 14,000 50,0 74,0 24,0 15,000 46,0 74,0 28,0 16,000 45,0 74,0 29,0 17,000 49,0 74,0 25,0 18,000 43,0 74,0 31,0 19,000 46,0 74,0 28,0 20,000 47,0 74,0 27,0 21,000 42,0 74,0 32,0 22,000 44,0 74,0 30,0 23,000 42,0 74,0 32,0 24,000 40,0 74,0 34,0 25,000 40,0 74,0 34,0 26,000 41,0 74,0 33,0 27,000 42,0 74,0 32,0 28,000 35,0 74,0 39,0 29,000 37,0 74,0 37,0 30,000 38,0 74,0 36,0 (Measured value = Wartość zmierzona)
AKREDYTOWANE LABORATORIUM BADAWCZE Page (Strona) 9 of (Stron) 9 Interference voltage at the Output (LOAD) - average value Niesymetryczne napięcie zakłóceń na przewodach obciąŝenia - wartości średnie freq. [MHz] Measured value; X1 X2 X3 X4 X5 Xsr Sn-1 Xsr+k Sn-1 Limit (Norma) Margin (Margines) 0,260 65,0 70,0 5,0 0,310 58,0 70,0 12,0 0,320 55,0 70,0 15,0 0,400 59,0 70,0 11,0 0,500 59,0 64,0 5,0 0,550 63,0 64,0 1,0 0,600 55,0 64,0 9,0 0,650 52,0 64,0 12,0 0,700 55,0 64,0 9,0 0,800 55,0 64,0 9,0 0,830 55,0 64,0 9,0 1,260 53,0 64,0 11,0 1,800 53,0 64,0 11,0 2,250 53,0 64,0 11,0 2,470 54,0 64,0 10,0 2,930 57,0 64,0 7,0 3,500 64,0 64,0 0,0 4,000 54,0 64,0 10,0 (Measured value = Wartość zmierzona)