LED PAR 64 COB 250W 5xWHITE P

Podobne dokumenty
LED WASHER 30x3W WHITE IP65 F

BLACKLIGHT SPOT 400W F

LED STROBE COB White 200W P

LED PAR 56 7x10 4in1 RGBW F

LED PAR 64 COB 250W 5xWHITE P

LED MAGIC BALL MP3 F

LED PAR 18x10W RGBW 4in1 Aluminum single cast II ver. F

LED PAR 64 7x10W RGBW 4in1 ABS Remote Control F

LED PAR 36 12x3W RGBW F

LED WASHER RGB IP34 F

LED PAR 18x10W RGBW 4in1 IP65 F

LED PAR 64 COB 300W RGBWA+UV P

LED MINI DERBY 4x3W RGBW F

LED PAR 64 18x10W 4in1 CLASSIC F

LED WALL WASHER 36x3W RGBW 3SC IP65 F

LED PAR 18x 10W RGBW 4in1 Aluminium single cast v.iii F B

LED PAR 64 SLIM 7x10W RGBW P

LED PAR 64 18x10W RGBW 4in1 IP64 PFC F

LED PAR 64 SLIM 7x10W RGBW PS0710

LED Spyder 8x10 CREE 4in1 F

LED PAR 56 Slim 18X3W RGB Aura F a

LED PAR Set 4x PAR 36 12x3W F

USER MANUAL / INSTRUKCJA OBSŁUGI. LED Double Derby 2x10W 4in1 F

LED PAR 64 18x12W RGBW 4in1 ZOOM IP65 F

LED PAR 64 COB 250W 5xWHITE Mk2 P

LED WALL WASHER 9x10W RGBW 4in1 DMX WIFI + ACU IP65 F a

LED PAR 64 COB RGBW PPC200

LED PAR 64 7x10W RGBW 4in1 ABS F

LED Spyder Mini 8x3W 4in1 RGBW F

LED MOVING HEAD STRONG 108x3W RGBW WASH III F c

LED MOVING HEAD 60W F

4 BEAM 4x10W LUMILUX LED RGBW 4in1 F

LED Głowica ruchoma 30W SPOT COLOR GOBO F

LED Double-sided WASH-BEAM Moving Head 4x10W + 1x10W F

LED MATRIX Moving Head 25x12W 4in1 NO LIMIT F

LED PAR 36 4x15W 4in1 ZOOM F

LED MH 7x10W RGBW 4in1 F

LED PAR 64 COB 200W RGBW Mk2 P

2x Moving Head 7R FL-233 BEAM+ Case F

LED MOVING HEAD MINI BEAM 18x3W RGB CREE F

2x Moving Head 15R BEAM FL Case F

LED PIXEL 30W RGBW 4in1 COB AutoDMX FastLOCK P

FOG MACHINE FLZ-2000 DMX + LED 3in1 RGB F

LED PAR 64 SLIM 7x10W RGBW Mk2 P

LED WASHER 18x10W RGBW 4in1 3 SECTIONS Mk2 25 /45 P /P

LED PAR 64 4x30W 4in1 COB RGBW 4 SECTIONS Mk2 P USER MANUAL / INSTRUKCJA OBSŁUGI

FOG MACHINE FLZ-1500 DMX+ RE F

FOG MACHINE FLM RE II ver. F

FOG MACHINE FLZ-1500 DMX LED+RE F

LED PAR 64 COB 300W RGBWA+UV P

LED PAR 64 COB 200W UV P

LED PAR 64 COB 300W UV P

15R MOVING HEAD "ALL IN ONE" F

Fog Machine FLZ-2000 RGB LED 3in1 F

Moving Head FL-232 BEAM 7R F

LED PAR 56 7*10W RGBW 4in1 SLIM

LED Moving Head 120W SPOT MK2 F

Wireless DMX 192CH controller F

LED PAR 64 COB 200W/300W UV Mk2 P /P

LED Mini Moving head light 60W LED,30W LED

INSTRUCTION MANUAL. Strona 1

LED PAR 64 COB 300W RGBWA+UV Mk2 P

GŁOWICA RUCHOMA LED 108x3W RGBW

LED SIX DERBY LIGHT Instrukcja obsługi

GŁOWICA RUCHOMA LED 144W. Instrukcja Obsługi. Strona 1


LED GŁOWICA RUCHOMA DOUBLE 72x3W RGB + WA INSTRUKCJA OBSŁUGI.

Instrukcja obsługi Głowica Ruchoma LED 15W


Owner s manual. English

Céliane TM Vac 50-60Hz. 1 x 2.5 mm 2 2 x 1.5 mm 2. Max. 400 W 400 W 400 VA 400 VA. 240 Vac. Min. 40 W 40 W 40 VA 40 VA

Camspot 4.4 Camspot 4.5

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

WYŁĄCZNIK CZASOWY OUTDOOR TIMER

Wersja polska PROLIGHT

Fixtures LED HEDRION

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

Tuber radio BT MA407. Instrukcja obsługi User s Manual

DC UPS. User Manual. Page 1

Rev Źródło:

LED Moving Head WASH 19x15W RGBW 4w1 ZOOM Osram F

LED Moving Head WASH 19x15W RGBW 4w1 ZOOM Osram MK2 F

FOLLOW SPOT FL-1200 DMX

LIGHT4ME IRON PAR RGBW

Volcano MC-GM4 OPTICAL MOUSE USER S MANUAL MODECOM

Hippo Boombox MM209N CD. Instrukcja obsługi User s Manual

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

MM210. Instrukcja obsługi User s Manual

Volcano MC-GMX4 OPTICAL MOUSE USER S MANUAL MODECOM

S-BAR INSTRUKCJA OBSŁUGI

LED Matrix 16X30W COB BLINDER

USB firmware changing guide. Zmiana oprogramowania za przy użyciu połączenia USB. Changelog / Lista Zmian

S-PAR INSTRUKCJA OBSŁUGI

LASER RED + VIOLET 300mW Instrukcja Obsługi

ONTEC C DYSKRETNA OCHRONA

Class B Radio Frequency. Statement Warning:

PLD48 PIXEL DMX LED Driver

PX 292. DMX/4-20mA interface INSTRUKCJA OBSŁUGI

KARTA KATALOGOWA RODZINY PRODUKTÓW PrevaLED Flat AC HF

4 Channel Video Server ACD Ver Quick Installation Guide

Transkrypt:

USER MANUAL / INSTRUKCJA OBSŁUGI LED PAR 64 COB 250W 5xWHITE P7100401

LED PAR 64 COB 250W 5xWHITE P7100401 Table of contents 1 Introduction... 2 2 Safety information... 2 3 Product information... 2 3.1 Features... 2 3.2 Specification... 2 4 Installation... 3 5 Connections... 3 5.1 Connecting DMX signal... 3 5.2 Voltage specification... 4 5.3 Connecting power supply... 4 6 Operation manual... 4 6.1 Control panel... 4 6.2 Menu... 4 6.3 DMX channel list... 6 Spis treści 1 Wprowadzenie... 7 2 Zasady bezpieczeństwa... 7 3 Informacje o produkcie... 7 3.1 Funkcje... 7 3.2 Specyfikacja... 7 4 Instalacja... 8 5 Połączenia... 8 5.1 Podłączenie sygnału DMX... 8 5.2 Specyfikacja zasilania... 9 5.3 Podłączanie zasilania... 9 6 Instrukcja użytkowania... 9 6.1 Panel sterowania... 9 6.2 Menu... 10 6.3 Lista kanałów DMX... 11 1 www.flash-butrym.pl

1 INTRODUCTION Thank you for purchasing LED PAR 64 COB 250W 5xWHITE. For safety reasons and to ensure the troublefree operation, carefully read the instructions. 2 SAFETY INFORMATION 1. Installation should be done by qualified personnel in order to minimize the risk of accidental electric shock 2. Disconnect the power supply before installation. 3. Before connecting the unit to the mains, make sure it is not damaged mechanically. If you notice any signs of damage you should contact your dealer immediately. Do not connect the device to the mains. 4. Do not use the device in high humidity conditions and at temperatures above 40 C 5. The device must be installed on stable structures 3 PRODUCT INFORMATION The device is equipped with high-quality, bright COB LED which consists of 5 rows of independently controlled LED chips with color temperatures of: 1. 1900-2100K 2. 3000-3200K 3. 4000-4300K 4. 5000-5500K 5. 9000-10000K Unique design, high quality and high durability make this device a great tool for both power users and those, who value simplicity and reliability. The ergonomic double bracket (included) facilitates the use of the device in any condition. In order to expand the range of mounting options, the holder has an additional mounting holes. The electronics is made of high quality components and offers several features such as: 3.1 Features Full DMX signal regeneration Electronic protection against overheating THEATRE or DISCO cooling volume modes. Permanent color correction Native support for optional wireless DMX module (optional) 3.2 Specification Power consumption: 250W Power supply voltage: 100-245V Voltage frequency: 50/60Hz Diode type: COB 6in1 Number of diodes: 1 Diode power: 250W Display: LCD Matrix Color: White: 2000K, 3000K, 4000K, 5000K, 9000K (smooth adjustment in the range of 2000-9000K) Color rendering index (CRI): 98 www.flash-butrym.pl 2

LED PAR 64 COB 250W 5xWHITE P7100401 Beam angle (min): 37 Beam angle (max): 37 Dimming: Linear: 0-100% Number of DMX channels: 7 / 8 DMX standard: DMX 512 Control interface: 4 buttons Operating modes: DMX512, Auto, Sound-controlled, Master / Slave, Manual color Features: DMX Signal regeneration, Electronic protection against overheating AC IN: powercon AC OUT: powercon DMX IN: XLR - 3 pin DMX OUT: XLR - 3 pin IP Rating: IP20 Housing made: ABS Cooling: Active Height [cm]: 30 Width [cm]: 27 Depth [cm]: 20 Weight [kg]: 3,8 Weight with packaging [kg]: 4,8 Set includes: Power cord, Double bracket, Barn Doors 4 INSTALLATION After removing the packaging, check if the device was not damaged during transport. Before connecting to the mains, make sure that the device is securely mounted. The manufacturer is not responsible for damage caused by unstable mounting. Ensure proper connection to the mains and proper grounding. Make sure that the electrical parameters are consistent with device requirements. All activities, including connecting the device to the mains must be performed by qualified personnel. 5 CONNECTIONS The device is equipped with the following interfaces: 1. DMX (in/out): XLR 3-pin socket 2. Power (in/out): powercon socket 5.1 Connecting DMX signal The connection is performed using cable with XLR-female -> XLR-Male plugs. 3 www.flash-butrym.pl

5.2 Voltage specification Input Voltage Total Power Frequency 100~245V 250W 50/60Hz 5.3 Connecting power supply The connection is performed using power cable with PowerCon connector (included). The device must be operated by qualified personnel. Make sure that the power grid supply parameters are consistent with device parameters and limitations are not exceeded. CAUTION! In the case of cable damage do not attempt to repair. Replacement or repair can be made only on the manufacturer or by a person with appropriate permissions. 6 OPERATION MANUAL 6.1 Control panel The control panel is equipped with LCD display and 4 control buttons with the following functions: 1. MENU enter to main menu, go back from the selected options, cancel changes 2. DOWN choose option, edit parameter 3. UP choose option, edit parameter 4. ENTER edit selected option, confirm changes 6.2 Menu Menu diagram: Change DMX Address Address (1-511) edit address ENTER change value UP/DOWN exit save value ENTER cancel MENU Set manual color and dimmer settings Manual settings (DIMMER, WHITE 1, WHITE 2, WHITE 3, WHITE 4, WHITE 5) edit settings ENTER change value UP/DOWN exit apply settings to device DISCONNECT DMX SIGNAL, WAIT 3 SEC save and go to next param. cancel current param. edit/back ENTER Turn on Sound Mode Sound (ON, OFF) turn on ENTER turn off ENTER/MENU www.flash-butrym.pl 4

LED PAR 64 COB 250W 5xWHITE P7100401 exit Turn On Manual (ON, OFF) turn on ENTER turn off HOLD ENTER/MENU exit Turn on Demo Mode Demo (ON, OFF) turn on ENTER turn off ENTER/MENU/UP/ DOWN exit Set DMX Channel Mode Channels (7, 8) edit ENTER change mode UP/DOWN exit save and exit ENTER cancel Device reaction after DMX signal disconnection DMX Off (BLACK, COLOR, DEMO, SOUND) edit ENTER change mode UP/DOWN exit save and exit ENTER cancel MENU Reset device Reset reset device ENTER Set fan noise level Fan Mode (DISCO, THEATRE) edit ENTER change mode UP/DOWN exit save and exit ENTER/MENU/ WAIT 5 SEC Set master or slave mode Mode (MASTER, SLAVE) edit ENTER change mode UP/DOWN exit save and exit ENTER/MENU/ WAIT 5 SEC Check device lifetime and actual temperature Lifetime (LIFETIME, TEMPERATURE) check temperature/ lifetime ENTER exit Adjust permanent color correction Color correction (WHITE 1, WHITE 2, WHITE 3, WHITE 4, WHITE 5) edit settings ENTER change value UP/DOWN exit save and go to next param. cancel current param. edit/back ENTER To achieve the desired effect after making changes in Manual settings, Demo or Sound mode, you should: 1. Disconnect DMX signal 2. Set the appropriate device response in Menu -> DMX off 3. Set and save the parameters in the selected mode (Manual settings, Demo, Sound) 4. Wait about 1s in order to the device detected the DMX signal status 5 www.flash-butrym.pl

6.3 DMX channel list 7CH mode Channel Function Effect CH 1 Dimmer 0-255: 0-100% CH 2 0-11: No Function 11-255: 1-20Hz CH 3 White 1 (1900-2100K warm) 0-255: 0-100% CH 4 White 2 (3000-3200K medium-warm 1) 0-255: 0-100% CH 5 White 3 (4000-4300K medium-warm 2) 0-255: 0-100% CH 6 White 4 (5000-5200K neutral) 0-255: 0-100% CH 7 White 5 (1900-2000K cold) 0-255: 0-100% 8CH mode Channel Function Effect CH 1 Dimmer 0-255: 0-100% CH 2 0-11: No Function 11-255: 1-20Hz CH 3 White 1 (1900-2100K warm) 0-255: 0-100% CH 4 White 2 (3000-3200K medium-warm 1) 0-255: 0-100% CH 5 White 3 (4000-4300K medium-warm 2) 0-255: 0-100% CH 6 White 4 (5000-5200K neutral) 0-255: 0-100% CH 7 White 5 (1900-2000K cold) 0-255: 0-100% CH 8 Color change 0-19: No Function 20-39: Color 1 40-59: Color 2 60-79: Color 3 80-99: Color 4 100-119: Color 5 120-139: Color 6 140-159: Color 7 160-179: Color 8 180-199: Color 9 200-219: Color 10 220-239: Color 11 240-255: Color 12 www.flash-butrym.pl 6

LED PAR 64 COB 250W 5xWHITE P7100401 1 WPROWADZENIE Dziękujemy za zakup urządzenia LED PAR 64 COB 250W 5xWHITE. Ze względów bezpieczeństwa oraz w celu zapewnienia bezawaryjnej pracy urządzenia należy dokładnie zapoznać się z instrukcją. 2 ZASADY BEZPIECZEŃSTWA 1. Instalacja powinna być przeprowadzana przez wykwalifikowany personel, aby zminimalizować ryzyko przypadkowego porażenia prądem 2. Przed instalacją należy odłączyć urządzenie od sieci 3. Przed podłączeniem urządzenia do sieci energetycznej należy sprawdzić, czy nie jest ono uszkodzone mechanicznie. Jeżeli widoczne są jakiekolwiek ślady uszkodzenia należy niezwłocznie skontaktować się z dystrybutorem. Nie podłączać urządzenia do sieci elektrycznej. 4. Nie należy korzystać z urządzenia w warunkach dużej wilgotności powietrza oraz w temperaturze powyżej 40 C 5. Urządzenie należy instalować na stabilnych konstrukcjach 3 INFORMACJE O PRODUKCIE Urządzenie wyposażone jest w wysokiej jakości, jasną diodę LED COB na którą składa się 5 rzędów niezależnie sterowanych chipów LED w kolorze białym o temperaturach: 1. 1900-2100K 2. 3000-3200K 3. 4000-4300K 4. 5000-5500K 5. 9000-10000K Wyjątkowe wzornictwo, wysoka jakość wykonania oraz materiały zapewniające dużą trwałość czynią to urządzenie doskonałym narzędziem zarówno dla wymagających użytkowników jak i osób ceniących prostotę i niezawodność. Znajdujący się w komplecie ergonomiczny uchwyt ułatwia korzystanie z urządzenia w każdych warunkach. W celu poszerzenia zakresu możliwości montażu urządzenia na konstrukcjach stalowych zastosowano w uchwycie dodatkowe otwory montażowe. Moduł elektroniczny wykonany z wysokiej jakości komponentów oferuje szereg funkcji takich jak: 3.1 Funkcje Pełna regeneracja sygnału DMX Elektroniczne zabezpieczenie przed przegrzaniem Możliwość wyboru spośród dwóch trybów głośności chłodzenia: THEATRE lub DISCO Możliwość stałej korekcji barwy Natywna obsługa opcjonalnego bezprzewodowego modułu DMX 3.2 Specyfikacja Pobór mocy: 250W Napięcie zasilania: 100-245V Częstotliwość napięcia: 50/60Hz Typ diody: COB 5w1 Ilość diod: 1 7 www.flash-butrym.pl

Moc diody: 250W Wyświetlacz: LCD Matrycowy Barwa: BIała: 2000K, 3000K, 4000K, 5000K, 9000K (płynna regulacja w zakresie 2000-9000K) Współczynnik oddawania barw (CRI): 98 Kąt świecenia (min): 37 Kąt świecenia (max): 37 Ściemnianie: Płynne: 0-100% Ilość kanałów DMX: 7 / 8 Standard DMX: DMX 512 Sterowanie: 4 przyciski Tryby pracy: DMX512, Auto, Sterowanie dźwiękiem, Master / Slave, Ręczne ustawienie kolorów Funkcje: Regeneracja sygnału DMX, Elektroniczne zabezpieczenie przed przegrzaniem AC IN: powercon AC OUT: powercon DMX IN: XLR - 3 pin DMX OUT: XLR - 3 pin Stopień ochrony IP: IP20 Rodzaj obudowy: ABS Chłodzenie: Aktywne Wysokość [cm]: 30 Szerokość [cm]: 27 Głębokość [cm]: 20 Waga [kg]: 3,8 Waga z opakowaniem [kg]: 4,8 W zestawie: Kabel zasilający, Podwójny pałąk, Zestaw przyslon zewnętrzynych (Barn Door) 4 INSTALACJA Po wyjęciu urządzenia z opakowania należy sprawdzić czy nie zostało ono uszkodzone podczas transportu. Przed podłączeniem do sieci elektrycznej należy upewnić się, że urządzenie zamocowane jest stabilnie. Producent nie ponosi odpowiedzialności za uszkodzenia spowodowane niestabilnym zamocowaniem urządzenia. Podczas korzystania z urządzenia należy zadbać o poprawne podłączenie go do sieci elektrycznej oraz prawidłowe uziemienie. Należy upewnić się, że parametry sieci elektrycznej są zgodne z wymaganiami urządzenia. Wszelkie czynności obejmujące obsługę w zakresie podłączania urządzenia do sieci elektrycznej powinny być wykonywane przez wykwalifikowany personel. 5 POŁĄCZENIA Urządzenie wyposażone jest w następujące interfejsy: 1. DMX (wejście/wyjście) złącza: XLR 3-pin 2. Zasilanie (wejście/wyjście) - złącza: powercon 5.1 Podłączenie sygnału DMX Połączenie odbywa się przy użyciu przewodu z wtyczkami XLR-Żeński -> XLR-Męski www.flash-butrym.pl 8

LED PAR 64 COB 250W 5xWHITE P7100401 5.2 Specyfikacja zasilania Napięcie zasilania Pobór mocy Częstotliwość zasilania 100~245V 250W 50/60Hz 5.3 Podłączanie zasilania Połączenie odbywa się przy użyciu przewodu zakończonego z jednej strony wtyczką sieci elektrycznej i wtyczką typu powercon z drugiej strony (w zestawie). Urządzenie musi być obsługiwane przez wykwalifikowany personel. Należy upewnić się, że parametry zasilania sieci energetycznej są zgodne z parametrami urządzenia i nie zostają przekroczone ograniczenia dotyczące poboru energii elektrycznej z sieci. UWAGA! W przypadku uszkodzenia przewodu nie należy dokonywać samodzielnej naprawy. Wymiana lub naprawa może być wykonana jedynie w serwisie producenta lub przez osobę z odpowiednimi uprawnieniami. 6 INSTRUKCJA UŻYTKOWANIA 6.1 Panel sterowania Panel sterowania wyposażony jest w wyświetlacz LCD oraz w 4 przyciski sterujące o następujących funkcjach: 1. MENU wejście do menu głównego, wyjście do menu z poziomu wybranej opcji, anulowanie zmian 2. DOWN wybór opcji, edycja parametru 3. UP wybór opcji, edycja parametru 4. ENTER edycja wybranej opcji, zatwierdzenie zmian 9 www.flash-butrym.pl

6.2 Menu Schemat menu urządzenia: Zmiana adresu DMX Address (1-511) edycja adresu ENTER zmiana wartości UP/DOWN wyjście MENU/CZEKAJ 5 S. zapisanie wartości ENTER anulowanie MENU Ręczna zmiana ustawień koloru i jasności Manual settings (DIMMER, WHITE 1, WHITE 2, WHITE 3, WHITE 4, WHITE 5) edycja parametrów wyjście MENU/CZEKAJ 5 S. zastosowanie ustawień ENTER zmiana wartości UP/DOWN ODŁĄCZ SYGNAŁ DMX, CZEKAK 3 S. zapisanie i przejście do nast. param. anulowanie zmian akt. param./wstecz ENTER MENU/CZEKAJ 5 S. Włączanie trybu sterowania dźwiękiem Sound (ON, OFF) włączanie ENTER wyłączanie ENTER/MENU wyjście MENU/CZEKAJ 5 S. Włączanie ręcznego trybu (ON, OFF) włączanie ENTER wyłączanie PRZYTRZYMAJ ENTER/MENU wyjście MENU/CZEKAJ 5 S. Włączanie trybu Demo Demo (ON, OFF) włączanie ENTER wyłączanie ENTER/MENU/UP/ DOWN wyjście MENU/CZEKAJ 5 S. Wybór trybu ilości kanałów DMX Channels (7, 8) edycja ENTER zmiana trybu UP/DOWN wyjście MENU/CZEKAJ 5 S. zapisanie i wyjście ENTER anulowanie MENU/CZEKAJ 5 S. Ustawienie reakcji na brak sygnału DMX DMX Off (BLACK, COLOR, DEMO, SOUND) edycja ENTER zmiana trybu UP/DOWN wyjście MENU/CZEKAJ 5 S. zapisanie i wyjście ENTER anulowanie MENU Reset urządzenia Reset reset urządzenia ENTER Wybór trybu głośności wentylatora Fan Mode (DISCO, THEATRE) edycja ENTER zmiana trybu UP/DOWN wyjście MENU/CZEKAJ 5 S. zapisanie i wyjście ENTER/MENU/ CZEKAJ 5 S. Wybór trybu współpracy z innymi urządzeniami Mode (MASTER, SLAVE) edycja ENTER zmiana trybu UP/DOWN wyjście MENU/CZEKAJ 5 S. zapisanie i wyjście ENTER/MENU/ CZEKAJ 5 S. www.flash-butrym.pl 10

LED PAR 64 COB 250W 5xWHITE P7100401 Wyświetlenie czasu pracy i aktualnej temperatury Lifetime (LIFETIME, TEMPERATURE) sprawdzenie temp./czasu pracy ENTER wyjście MENU/CZEKAJ 5 S. Ustawienie stałej korekcji barw Color correction (WHITE 1, WHITE 2, WHITE 3, WHITE 4, WHITE 5) edycja parametrów wyjście MENU/CZEKAJ 5 S. ENTER zmiana wartości UP/DOWN zapisanie i przejście do nast. param. anulowanie zmian akt. param./wstecz ENTER MENU/CZEKAJ 5 S. Aby uzyskać wybrany efekt po zmianie ustawień trybów: Manual settings, Demo, Sound należy: 1. Odłączyć sygnał DMX 2. Ustawić odpowiednią reakcję urządzenia w Menu -> DMX off 3. Ustawić parametry w wybranym trybie (Manual settings, Demo, Sound) 4. Odczekać około 1s aby urządzenie wykryło stan sygnału DMX 6.3 Lista kanałów DMX Tryb 7CH Kanał Funkcja Działanie CH 1 Ściemnianie 0-255: 0-100% CH 2 0-11: Brak działania 11-255: 1-20Hz CH 3 Biały 1 (1900-2100K ciepły) 0-255: 0-100% CH 4 Biały 2 (3000-3200K średnio-ciepły 1) 0-255: 0-100% CH 5 Biały 3 (4000-4300K średnio-ciepły 2) 0-255: 0-100% CH 6 Biały 4 (5000-5200K naturalny) 0-255: 0-100% CH 7 Biały 5 (1900-2000K zimny) 0-255: 0-100% Tryb 8CH Kanał Funkcja Działanie CH 1 Ściemnianie 0-255: 0-100% CH 2 0-11: Brak działania 11-255: 1-20Hz CH 3 Biały 1 (1900-2100K ciepły) 0-255: 0-100% CH 4 Biały 2 (3000-3200K średnio-ciepły 1) 0-255: 0-100% CH 5 Biały 3 (4000-4300K średnio-ciepły 2) 0-255: 0-100% CH 6 Biały 4 (5000-5200K naturalny) 0-255: 0-100% CH 7 Biały 5 (1900-2000K zimny) 0-255: 0-100% CH 8 Zmiana koloru 0-19: Brak działania 20-39: Kolor 1 40-59: Kolor 2 60-79: Kolor 3 80-99: Kolor 4 100-119: Kolor 5 120-139: Kolor 6 140-159: Kolor 7 160-179: Kolor 8 180-199: Kolor 9 200-219: Kolor 10 220-239: Kolor 11 240-255: Kolor 12 11 www.flash-butrym.pl