MONITORING OF CAPILLARY RISE PHENOMENON IN CALCIUM SILICATE BOARD USING THE SURFACE TDR PROBES SET

Podobne dokumenty
EXAMINATION OF CAPILLARY RISE PHENOMENON IN AERATED CONCRETE BLOCK USING THE SURFACE TDR PROBE

Analiza przewodności cieplnej przegród z betonu komórkowego w zależności od zmian wilgotności

MODIFICATION OF THE MEASUREMENT METHOD OF RELATIVE MOISTURE DETERMINATION USING PELTIER PROBE

Spis publikacji. dr inż. Zbigniew Suchorab telefon:

WATER CONTENT MEASUREMENT IN BUILDING BARRIERS AND MATERIALS USING SURFACE TDR PROBE

WYZNACZANIE KRZYWEJ RETENCJI WODY MATERIAŁÓW POROWATYCH ZA POMOCĄ SOND PSYCHROMETRYCZNYCH I TDR

INSPECTION METHODS FOR QUALITY CONTROL OF FIBRE METAL LAMINATES IN AEROSPACE COMPONENTS

CAPILLARY RISE PHENOMENON IN AERATED CONCRETE. MONITORING AND SIMULATIONS

In-situ. Using. Introduction. Zbigniew Suchorab. us and may be caused by many. reasons. the. nal parts of the. to the material. skin irritations.

ROZPRAWA DOKTORSKA. Model obliczeniowy ogrzewań mikroprzewodowych

The analysis of the energy demand for heating and cooling of the house built on the basis of the traditional Canadian wood-frame construction

ZASTOSOWANIE METODY TDR DO POMIARU PODCIĄGANIA KAPILARNEGO W ŚCIANCE MODELOWEJ Z CEGŁY CERAMICZNEJ PEŁNEJ

TECHNICAL CATALOGUE WHITEHEART MALLEABLE CAST IRON FITTINGS EE

Ocena zjawiska podciągania kapilarnego w murze budynku o charakterze zabytkowym za pomocą powierzchniowej sondy TDR

PROCEEDINGS OF THE INSTITUTE OF VEHICLES 2(106)/2016 (12 pt)

BARIERA ANTYKONDENSACYJNA

Cracow University of Economics Poland. Overview. Sources of Real GDP per Capita Growth: Polish Regional-Macroeconomic Dimensions

Zakopane, plan miasta: Skala ok. 1: = City map (Polish Edition)

THE DETERIORATION OF STRENGTH AND THERMAL PROPERTIES OF AUTOCLAVED AERATED CONCRETE AS A RESULT OF CAPILLARY MOISTURE

Has the heat wave frequency or intensity changed in Poland since 1950?

AN EFFECT OF FLOW NON-UNIFORMITY IN EARTH-TO-AIR MULTI-PIPE HEAT EXCHANGERS (EAHEs) ON THEIR THERMAL PERFORMANCE

Fig 5 Spectrograms of the original signal (top) extracted shaft-related GAD components (middle) and

Cracow University of Economics Poland

Zastosowanie techniki pomiarowej TDR w badaniach terenowych przy wykorzystaniu sond powierzchniowych

DETECTION OF MATERIAL INTEGRATED CONDUCTORS FOR CONNECTIVE RIVETING OF FUNCTION-INTEGRATIVE TEXTILE-REINFORCED THERMOPLASTIC COMPOSITES

EXAMPLES OF CABRI GEOMETRE II APPLICATION IN GEOMETRIC SCIENTIFIC RESEARCH

DM-ML, DM-FL. Auxiliary Equipment and Accessories. Damper Drives. Dimensions. Descritpion

p ISSN TRIBOLOGIA 1/2018 Key words: Abstract

Zarządzanie sieciami telekomunikacyjnymi

WYKAZ DOROBKU NAUKOWEGO

BIOPHYSICS. Politechnika Łódzka, ul. Żeromskiego 116, Łódź, tel. (042)

SZKŁO PIANKOWE JAKO TERMOIZOLACJA PODŁOGI NA GRUNCIE USE OF FOAM GLASS AS A SLAB ON GRADE THERMAL INSULATION

A BUILDING MADE OF POLYSTYRENE PREFABRICATES FROM THE PERSPECTIVE OF NEW TECHNICAL CONDITIONS AND STANDARDS OF NF15 AND NF40


Proposal of thesis topic for mgr in. (MSE) programme in Telecommunications and Computer Science

Typ VFR. Circular flow adjustment dampers for the adjustment of volume flow rates and pressures in supply air and extract air systems

MaPlan Sp. z O.O. Click here if your download doesn"t start automatically

Lecture 18 Review for Exam 1

TYRE PYROLYSIS. REDUXCO GENERAL DISTRIBUTOR :: ::


MOśLIWOŚĆ POMIARU ZASOLENIA W MATERIAŁACH BUDOWLANYCH ZA POMOCĄ METODY TDR

DUAL SIMILARITY OF VOLTAGE TO CURRENT AND CURRENT TO VOLTAGE TRANSFER FUNCTION OF HYBRID ACTIVE TWO- PORTS WITH CONVERSION

1. Podstawa opracowania recenzji

Installation of EuroCert software for qualified electronic signature

POMIARY ROZKŁADU WILGOTNOŚCI I PARAMETRÓW CIEPLNYCH BETONU KOMÓRKOWEGO KLAS 400 i 700 W TRAKCIE 6-MIESIĘCZNEGO WYSYCHANIA

Typ VFR. Circular flow adjustment dampers for the adjustment of volume flow rates and pressures in supply air and extract air systems

Domy inaczej pomyślane A different type of housing CEZARY SANKOWSKI

Typ TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

ROZPRAWY NR 128. Stanis³aw Mroziñski

Struktury proponowane dla unikalnych rozwiązań architektonicznych.

Zmiany techniczne wprowadzone w wersji Comarch ERP Altum

Analiza porównawcza zmian w rozbiorach wody z uwzględnieniem sposobu jej dostarczania do odbiorców

CATALOGUE CARD LEO S L XL / BMS KARTA KATALOGOWA LEO S L XL / BMS

KARTA KATALOGOWA RODZINY PRODUKTÓW PrevaLED Flat AC HF

INFRARED BUILDING HEATING BOARDS

Sargent Opens Sonairte Farmers' Market

Raport bieżący: 44/2018 Data: g. 21:03 Skrócona nazwa emitenta: SERINUS ENERGY plc

Uniwersytet Medyczny w Łodzi. Wydział Lekarski. Jarosław Woźniak. Rozprawa doktorska

BLACKLIGHT SPOT 400W F

DOI: / /32/37

HAPPY ANIMALS L01 HAPPY ANIMALS L03 HAPPY ANIMALS L05 HAPPY ANIMALS L07

HAPPY ANIMALS L02 HAPPY ANIMALS L04 HAPPY ANIMALS L06 HAPPY ANIMALS L08

Profil Czasopisma / The Scope of a Journal

Metodyki projektowania i modelowania systemów Cyganek & Kasperek & Rajda 2013 Katedra Elektroniki AGH

Patients price acceptance SELECTED FINDINGS

Stargard Szczecinski i okolice (Polish Edition)

SPITSBERGEN HORNSUND

099 Łóżko półpiętrowe 2080x1010(1109)x Bunk bed 2080x1010(1109)x1600 W15 INSTRUKCJA MONTAŻU ASSEMBLY INSTRUCTION

WENYLATORY PROMIENIOWE ROOF-MOUNTED CENTRIFUGAL DACHOWE WPD FAN WPD

DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE!


ANALYSIS OF VOLUME CHANGES OF SELECTED CEREAL GROUND GRAIN IN RESULT OF LOADING*

Medical electronics part 10 Physiological transducers

WENTYLATORY PROMIENIOWE SINGLE-INLET DRUM BĘBNOWE JEDNOSTRUMIENIOWE CENTRIFUGAL FAN

DELTIM Sp. z o.o. S.K.A ul. Rząsawska 30/38; Częstochowa. Bumper bar X-Lander X-Move

SHP / SHP-T Standard and Basic PLUS

SSW1.1, HFW Fry #20, Zeno #25 Benchmark: Qtr.1. Fry #65, Zeno #67. like

ELECTRIC AND MAGNETIC FIELDS NEAR NEW POWER TRANSMISSION LINES POLA ELEKTRYCZNE I MAGNETYCZNE WOKÓŁ NOWYCH LINII ELEKTROENERGETYCZNYCH

European Crime Prevention Award (ECPA) Annex I - new version 2014

Helena Boguta, klasa 8W, rok szkolny 2018/2019

SPITSBERGEN HORNSUND

ETICS: Few words about the Polish market Dr. Jacek Michalak Stowarzyszenie na Rzecz Systemów Ociepleń (SSO), Warsaw, Poland

WSPÓŁCZYNNIK SORPCJI BETONU KOMÓRKOWEGO BADANY NA PRÓBKACH SUSZONYCH I NIESUSZONYCH

W trzech niezależnych testach frezy z powłoką X tremeblue typu V803 był w każdym przypadku prawie 2 razy bardziej wydajne niż wersja niepowlekana.

Typ VME FOR THE MEASUREMENT OF VOLUME FLOW RATES IN DUCTS

Few-fermion thermometry

HAPPY K04 INSTRUKCJA MONTAŻU ASSEMBLY INSTRUCTIONS DO MONTAŻU POTRZEBNE SĄ DWIE OSOBY! INSTALLATION REQUIRES TWO PEOPLE! W5 W6 G1 T2 U1 U2 TZ1

Formularz recenzji magazynu. Journal of Corporate Responsibility and Leadership Review Form

INVESTIGATION OF SCREWS FOUND IN WILHELM ORE MINE

Power cables with XLPE insulation

WPŁYW WILGOTNOŚCI SORPCYJNEJ NA PRZEWODNOŚĆ CIEPLNĄ BETONÓW KOMÓRKOWYCH

098 Łóżko piętrowe 2080x1010(1109)x Double bunk bed 2080x1010(1109)x1600 W15 MONTAGEANLEITUNG ASSEMBLY INSTRUCTION

WYŁĄCZNIK CZASOWY OUTDOOR TIMER

PROCEEDINGS OF THE INSTITUTE OF VEHICLES 5(109)/2016

Compression strength of pine wood (Pinus Sylvestris L.) from selected forest regions in Poland, part II

Microsystems in Medical Applications Liquid Flow Sensors

Politechnika Krakowska im. Tadeusza Kościuszki. Karta przedmiotu. obowiązuje studentów rozpoczynających studia w roku akademickim 2014/2015

WENTYLATORY PROMIENIOWE MEDIUM-PRESSURE CENTRIFUGAL

SPITSBERGEN HORNSUND

Installation screened cables with PVC insulation

Transkrypt:

Proceedings of ECOpole DOI: 10.2429/proc.2014.8(1)010 2014;8(1) Zbigniew SUCHORAB 1 MONITORING OF CAPILLARY RISE PHENOMENON IN CALCIUM SILICATE BOARD USING THE SURFACE TDR PROBES SET MONITORING PROCESU PODCIĄGANIA KAPILARNEGO W SILIKACIE WAPIENNYM ZA POMOCĄ POWIERZCHNIOWYCH SOND TDR Abstract: Capillary rise phenomenon is a process threatening many building objects. It is mainly caused by the capillary structure of most building materials. The described phenomenon relies on water flow against gravity forces and hydrostatic pressure. The problem of capillary uptake is especially visible in case of lack of horizontal or vertical water isolation layers, their damage or natural wear during long time exploitation. The sufficient condition for capillary rise phenomenon appearance is constant contact of the building barriers to the moist ground. Described phenomenon is dangerous because the range of its influence can reach even 2.5 m or more above ground level, depending on building material. Capillary uptake is a dangerous process, because it runs to barriers destruction and decrease of its strength and heat parameters. Excessive water is the reason of biological strokes of the buildings, mainly caused by mould. The article presents the experimental research of capillary rise phenomenon in a sample of autoclaved calcium silicate. For the experiment it is applied the setup of TDR sensors prototypes which enable constant monitoring of the described phenomenon in non-invasive way. Keywords: capillary rise, calcium silicate, surface probes TDR, monitoring Introduction This article is devoted to the capillary rise phenomenon and the possibility of its monitoring in autoclaved calcium silicate being an insulating material. Capillary rise is one of the most threatening problems observed in many buildings [1, 2]. It causes the damage of external barriers, funds and runs to many exploitation problems like biological corrosion [3, 4], decrease of indoor air parameters and the decrease of thermal parameters of the materials [5-8]. A very interesting building material is autoclaved calcium silicate sold in Polish market as Renovario/Calsitherm and distributed by Ecovario Ltd Company [9]. It was elaborated in Germany by Häupl [10] at the end of the previous Century. Autoclaved calcium silicate is produced in form of plates with the dimensions of 1250 1000 mm and 25, 30 or 50 mm thickness [9]. The plates are made of calcium silicate being the mineral based material. Crystals of calcium silicate form the microporous shell, which provides the great capillarity of the ready material [11]. The most important parameters of Calsitherm plates, influencing their application are bulk density, porosity, compression strength and heat conductivity coefficient. All of them are set together in the Table 1, following the distributor webpage [9]. 1 Faculty of Environmental Engineering, Lublin University of Technology, ul. Nadbystrzycka 40B, 20-618 Lublin, Poland, phone +48 81 538 43 22, email: Z.Suchorab@wis.pol.lublin.pl * Contribution was presented during ECOpole 12 Conference, Zakopane, 10-13.10.2012

82 Zbigniew Suchorab Technical data of autoclaved calcium silicate plates [9] Parameter Unit Value Bulk density [kg/m 3 ] 200-240 Porosity [%] over 90 Compression strength [MPa] 1 Heat conductivity coefficient (dry plate) [W/(m K)] 0.060 Heat conductivity coefficient (wet plate) [W/(m K)] 0.059 Table 1 From the technical data presented in the table above it is visible that Calsitherm plates can be considered as insulation material with average insulating parameters (significantly lower, comparing to the other common materials like mineral wool or polystyrene). On the other hand their great porosity, exceeding 90% and microporous structure (Fig. 1) causes that they can be applied for internal insulation of the walls which should not be insulated from the outside. This is especially applicable for the old historical objects. Fig. 1. SEM photography of autoclaved calcium silicate structure [12] Indoor insulation layer, comparing to the traditional external insulation techniques does not provide suitable temperature distribution inside the building envelopes. In most cases this runs to water vapor condensation inside of them. It must be underlined here, that great porosity and water absorptivity of calcium silicate forces the wall to transfer condensed water into the insulation material which can be safely removed to the indoor air during dry periods of the year [2]. Materials and methods As it was underlined in the above chapter, autoclaved calcium silicate is characterized by strong capillary forces and great water absorptivity. This paper presents research of water absorptivity of autoclaved calcium silicate. For the experiment, the autoclaved calcium silicate (Calsitherm plate) sample was put to the container with constant water level and exposed to water uptake process (Fig. 2). Dimensions of the sample (Fig. 3) were the following: 580 mm (height) 280 mm (width) 50 mm (thickness). Bottom 20 mm of the sample was submerged into water, and moisture sensors were placed at the following heights over water level: 100 mm (probe 00), 200 mm (probe 16), 300 mm (probe 32), 400 mm (probe 48), 500 mm (probe 64).

Monitoring of capillary rise phenomenon in calcium silicate board using the surface TDR probes set 83 For the experiment it was applied the TDR (Time Domain Reflectometry) methodology, previously applied by the author of this paper for moisture determination in soils [13] and building materials and envelopes [14-17]. The application of the TDR methodology was strongly limited to soils and light building materials due to its invasive character and the necessity to install the measuring elements into the structure of measured barrier. This ran to measured material destruction and readouts falsification because of the steel elements internal installation. To obtain the possibility of noninvasive, constant monitoring of the described phenomenon it was used an unique system of modified TDR probes (Figs. 2-4). The traditional TDR probes were reduced to measuring bars, which were separated with plastic dielectric material, that enabled to keep constant, parallel bars distribution and made it easier to attach the measuring elements to the sample. Measuring elements were made of brass angle-bars with the following dimensions: 200 mm (length), 10 mm (sides of the bars). Space between the bars was 40 mm and the total width of the probe was 60 mm. The terminations of the angle bars were connected to the concentric cable which distributed the electromagnetic signal from the described sensors to the TDR multimeter presented at Figure 2. Such prepared probes attached to the material sample and the whole measuring setup are presented at Figures 2 and 3. Fig. 2. Measuring setup during experiment To avoid any influence of the external conditions on the sample and uptake process, the sample, together with the probes was covered with insulating foil. Sensors were connected to the typical TDR multimeter (EasyTest/Lublin/Poland) which was controlled by PC computer. Measurement sequence was repeated every 15 minutes and the readouts were made at each attitude (every probe). Modified system of the TDR probes required to elaborate special software which enabled to control the device and interpret the obtained results. The redouts from the multimeter were obtained as the TDR reflectograms, that, after suitable postprocessing (location of signal peaks and calculation of time intervals) and

84 Zbigniew Suchorab empirical calibration (Fig. 2) enabled to monitor moisture changes at each level of the examined sample. Fig. 3. Probes attached to the examined material Results Before the experiment started all probes were calibrated for moisture. Probe during calibration procedure is presented at Figure 4. Fig. 4. Surface probe calibration for autoclaved calcium silicate Calibration experiment of surface TDR probes is presented in the following paper [18]. After calibration procedure was conducted, the equation (1) was elaborated, which was then applied to recalculate moisture from the TDR readouts: Ɵ = 0.0023 t 2 + 1.4227 t 127.74 (1) where: t - signal travel time along the angle bar of the sensor [ps], Ɵ - volumetric water content [% vol.]. The diagram presented at Figure 5 represents the progress of the water uptake phenomenon in Calsitherm sample. It is clearly visible that water quickly appears at Probe 00 placed 100 mm above water level. Rate of the moisture increase is very high and after 2 hours a state near maximum water content is reached. Moisture increase read by the above probes is postponed for average period of 5 hours but still is very rapid and quickly after water appears, maximum moisture is reached. Moisture increases appear after 4 hours at Probe 16, after 9 hours at Probe 32, after 13 hours at Probe 48 and finally after 20 hours at Probe 64.

Monitoring of capillary rise phenomenon in calcium silicate board using the surface TDR probes set 85 Fig. 5. Water uptake process determined in calcium silicate Presented research confirms high water absorptivity of autoclaved calcium silicate (Calsitherm plates) declared by the producers and distributors. Modified TDR sensors confirmed that maximum water content for the described material exceeds 90% and maximum moisture states are achieved quickly after water appears. This confirms high capillary forces and unique capillary structure of the discussed material. Conclusions Basing on the conducted experiment the following conclusions may be drawn: described experiment proved high potential of the TDR method for monitoring of moisture changes phenomena in building materials, setup applied for the described experiment is unique and its application required modification of applied probes construction and special software, conducted research confirmed high water absorptivity of autoclaved calcium silicate, uniform porous structure causes a predictive water uptake process which runs rapidly and quickly after water appears, maximum water content is reached. References [1] [2] [3] [4] [5] [6] [7] Rokiel M. Hydroizolacje w budownictwie. Warszawa: Wyd Medium; 2006. Klemm P, editor. Budownictwo ogólne. Tom 2. Fizyka budowli. Warszawa: Wyd Arkady; 2005. Zyska B. Zagrożenia biologiczne w budynku. Warszawa: Wyd Arkady; 1999. Ważny J, Karyś J, editors. Ochrona budynków przed korozją biologiczną. Warszawa: Wyd Arkady; 2001. Williams R. Overview of the project to determine the thermal resistance of masonry walls in dry and moist states and a conversion procedure to determine the appropriate design value. Building Phys. 2002-6th Nordic Symposium; 539-546. Gawin D, Kosny J, Desjarlais A. Effect of Moisture on Thermal Performance and Energy Efficiency of Buildings with Lightweight Concrete Walls. Proc. of 2000 Summer Study on Energy Efficiency in Buildings Efficiency & Sustainability, 2000, Pacific Grove, California (USA), 3.149-3.160. Suchorab Z, Sobczuk H, Skwarczyński M. Determination of red brick conductivity coefficient depending on moisture. Thermophysics 2010, Conference Proc. Czech Republic, 283-289.

86 Zbigniew Suchorab [8] Suchorab Z, Barnat-Hunek D, Sobczuk H. Influence of moisture on heat conductivity of aerated concrete. Ecol Chem Eng S. 2011;18(1):111-120. [9] www.ecovario.pl. [10] Häupl P, Grunewald J, Fechner H. Moisture behaviour of a Gründerzeit - house by meansof a capillary active calciumsilicate inside insulation. Proc of the Building Phys in the Nordic Countries. Göteborg: 1999, 225-232. [11] Barnat-Hunek D, Karwacka A, Stankiewicz K, Kowalczyk A. Analiza cieplno-wilgotnościowa przegród zewnętrznych docieplonych od strony wewnętrznej. Energy-saving and ecological materials, installations and technology in construction. Biała Podlaska: 2012;9-18. [12] Hamilton A, Hall C. Physicochemical characterization of a hydrated calcium silicate board material. J Building Phys. 2005;29:9-19. DOI: 10.1177/1744259105053280. [13] Suchorab Z, Sobczuk H, Rożej A, Łagód G. Comparison of reflectometric and gravimetric method for examination of sewage sludge additions influence on water properties of reclamated soils. Proc ECOpole'05, Jamrozowa Polana - Hradec Kralove, 20-22 X 2005;281-286. [14] Sobczuk H, Suchorab Z. Calibration of TDR instruments for moisture measurement of aerated concrete. Monitoring and modelling the properties of soil as porous medium. Lublin: Institute of Agrophysics Polish Academy of Sciences; 2005;158-165. [15] Suchorab Z, Barnat-Hunek D, Sobczuk H. Technika reflektometryczna w badaniach wilgotnościowych murów. Builder. 2007;(2):84-86. [16] Suchorab Z, Widomski M, Łagód G, Sobczuk H. Capillary rise phenomenon in aerated concrete. Monitoring and simulations. Proc ECOpole. 2010;4(2):285-290. [17] Guz Ł, Suchorab Z, Alcobia B, Sobczuk H. Wyznaczanie krzywej retencji wody materiałów porowatych za pomocą sond psychrometrycznych i TDR. Proc ECOpole. 2010;4(2):371-375. [18] Suchorab Z, Jedut A, Sobczuk H. Water content measurement in building barriers and materials using surface TDR probe. Proc ECOpole. 2008;2(1):123-127. MONITORING PROCESU PODCIĄGANIA KAPILARNEGO W SILIKACIE WAPIENNYM ZA POMOCĄ POWIERZCHNIOWYCH SOND TDR Wydział Inżynierii Środowiska, Politechnika Lubelska Abstrakt: Podciąganie kapilarne jest procesem dotykającym wiele obiektów budowlanych. Przyczyną jego występowania jest kapilarna struktura większości materiałów budowlanych. Zjawisko to polega na przepływie wody w kierunku niezgodnym z siłami grawitacji, wbrew ciśnieniu hydrostatycznemu. Omawiany problem podciągania kapilarnego jest szczególnie widoczny w przypadku braku poziomych i pionowych izolacji przeciwwilgociowych, ich uszkodzenia lub przy naturalnym ich zużyciu w czasie wieloletniej eksploatacji. Warunkiem wystarczającym do rozpoczęcia procesu podciągania kapilarnego wody do wyższych partii ścian jest styczność przegród budowlanych z gruntem o naturalnej wilgotności. Zjawisko to jest niezwykle niebezpieczne, ponieważ zasięg jego oddziaływania może osiągać nawet wysokość do 2,5 m od poziomu gruntu lub więcej w zależności od materiału budowlanego. Podciąganie kapilarne jest procesem szkodliwym, ponieważ prowadzi do degradacji przegrody, obniża jej właściwości konstrukcyjne oraz cieplne. Nadmierna ilość wody w przegrodzie jest przyczyną porażeń biologicznych budynków, z których najczęściej spotykanym problemem jest zagrzybienie. W artykule przedstawiono badania eksperymentalne procesu podciągania kapilarnego w próbce z autoklawizowanego silikatu wapiennego. Do badań zastosowano zestaw prototypowych czujników TDR, dzięki którym możliwy jest ciągły monitoring zjawiska w sposób bezinwazyjny. Słowa kluczowe: podciąganie kapilarne, autoklawizowany silikat wapienny, powierzchniowe sondy TDR, monitoring