Dual Display Digital Multimeter D6 FEATURES * 50000 Counts Display * Multi-Function ACV, DCV, ACA, DCA, R, C, Hz, Continuity Beeper, Diode Test, Max/Min, REL, Hold, dbm * Dual Display Indicate ACV and Hz or DCV(ACV) and dbm * Manual or Autoranging * 0.03% DCV Accuracy * 20A High Current Range * 1200V High Voltage Range * AC True R.M.S. or AC+DC True R.M.S. GDM-8245 (50000 Counts) DC VOLTAGE Range 500mV, 5V, 50V, 500V, 1200V 5 ranges Accuracy (0.03% rdg + 4 digits) 1200V range (0.03% rdg + 9 digits) Input Impedance 10M AC VOLTAGE True RMS (AC or AC+DC True RMS) Range 500mV, 5V, 50V, 500V, 1000V 5ranges Accuracy 500mV~50V 3 ranges:20hz~45hz (1% rdg+15 digits) 45Hz ~ 2kHz (0.5% rdg + 15 digits) 2k~10kHz (1% rdg + 15 digits) 10kHz ~ 20kHz (2% rdg + 30 digits) 20kHz~50kHz (5% rdg + 30digits) 500V,1000V range:45hz~1khz (0.5% rdg+15 digits) Input Impedance 10M DC CURRENT Range Accuracy RESISTANCE Range Accuracy DIODE TEST The one range can check the forward voltage of diode. Maximum forward voltage 1.5V, Open voltage 2.8V CAPACITANCE Range Accuracy FREQUENCY Input Level (Sine Wave) SPECIFICATIONS 500 A, 5mA, 50mA, 500mA, 2A, 20A 6 ranges 500 A ~ 500mA 4 ranges : (0.2% rdg + 2 digits) 2A ~ 20A 2 ranges : (0.3% rdg +2 digits) AC CURRENT True RMS (AC or AC+DC True RMS) Range 500 A, 5mA, 50mA, 500mA, 2A, 20A 6 ranges Accuracy 500 A ~ 500mA 4 ranges : 45Hz ~ 2kHz (0.5% rdg + 15 digits) 2kHz ~ 10kHz (1% rdg + 15 digits);10khz ~ 20kHz (2% rdg + 15 digits) 2A~20A 2 ranges:45hz~2khz (0.5% rdg+15 digits) 500, 5k, 50k, 500k, 5M, 20M 6 ranges 500 range : (0.1% rdg + 4digits) 5k ~ 500k 3 ranges : (0.1% rdg + 2 digits) 5M range : (0.2% rdg + 2 digits) 20M range : (0.3% rdg + 2 digits) 5nF, 50nF, 500nF, 5 F, 50 F 5 ranges (2% rdg + 4 digits) mv range : >120mV (10Hz ~ 50kHz) >200mV (50k ~ 150kHz) 5V range : >1V (10Hz ~ 200kHz) 50V range : >1.2V (20Hz ~ 200kHz) 500V range : >12V (20Hz ~ 1kHz) CONTINUITY BEEPER NMRR <5 CMRR > 60dB OPERATING MODE > 90dB OTHERS AUTO RANGE / MANUAL MAX, MIN, dbm (63.8dBm ~ -97.7dBm), REL, HOLD DISPLAY Dual Display 0.4, 0.5, 7 segment LED display POWER SOURCE AC 100V/120V/230V 15%, 50/60Hz ACCESSORIES Instruction manual x 1, Power cord x 1, Test lead GTL-117 x 1 DIMENSIONS & WEIGHT 251(W) x 91(H) x 291(D) mm, Approx. 2.6 kg ORDERING INFORMATION GDM-8245 50000 Counts Dual Display Digital Multimeter
PC500a PC510a DIGITAL MULTIMETER INSTRUCTION MANUAL
OVERVOLTAGE CATEGORY Equipment of CAT is equipment for connection to circuits in which measures are taken to limit the transient overvoltages to an appropriate low level. Note: Examples include protected electronic circuits. Equipment of CAT is energy-consuming equipment to be supplied from the fixed installation. Note: Examples include household, office, and laboratory appliances. Equipment of CAT is equipment in fixed installations. Note: Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. Equipment of CAT is for use at the origin of the installation. Note: Examples include electricity meters and primary overcurrent protection equipment. 8-2 Measurement Range and Accuracy Accuracy assurance range: 23 5, 75%RH MAX. No condensation. TRUE RMS ACV & ACA accuracies are specified from 5 % to 100 % of range or otherwise specified, crest factor <3:1 at full scale & <6:1 at half scale, and with frequency component within the specified frequency bandwidth DC Voltage RANGE Accuracy 50.00 mv 0.12% rdg + 2dgt 500.0 mv 0.06% rdg + 2dgt 5.000V, 50.00V, 500.0V, 1000V 0.08% rdg + 2dgt NMRR:>60dB @ 50/60Hz CMRR:>120dB @ DC, 50/60Hz, Rs=1kΩ Input Impedance: 10MΩ, 16pF nominal (44pF nominal for 50mV & 500mV ranges) 34
AC Voltage RANGE Accuracy 50Hz - 60Hz 50.00mV, 500.0mV, 5.000V, 0.5% rdg + 3dgt 50.00V, 500.0V, 1000V 40Hz - 500Hz 50.00mV, 500.0mV 0.8% rdg + 3dgt 5.000V, 50.00V, 500.0V 1.0% rdg + 4dgt 1000V 1.2% rdg + 4dgt Up to 20kHz 50.00mV, 500.0mV 0.5dB** 5.000V, 50.00V, 500.0V 3dB** 1000V Unspec'd CMRR:>60dB @ DC to 60Hz, Rs=1kΩ Input Impedance: 10MΩ, 16pF nominal (44pF nominal for 50mV & 500mV ranges) **Specified from 30% to 100% of range DC Current RANGE Accuracy Burden Voltage 500.0µA 0.15mV/µA 5000µA 0.15mV/µA 50.00mA 3.3mV/mA 0.2% rdg + 4dgt 500.0mA 3.3mV/mA 5.000A 0.03V/A 10.00A* 0.03V/A *10A continuous 35
AC Current RANGE Accuracy Burden Voltage 50Hz - 60Hz 500.0µA 0.15mV/µA 5000µA 0.6% rdg +3dgt 0.15mV/µA 50.00mA 3.3mV/mA 500.0mA 1.0% rdg +3dgt 3.3mV/mA 5.000A 0.03V/A 0.6% rdg +3dgt 10.00A* 0.03V/A 40Hz - 1kHz 500.0µA 0.15mV/µA 5000µA 0.8% rdg +4dgt 0.15mV/µA 50.00mA 3.3mV/mA 500.0mA 3.3mV/mA 5.000A 1.0% rdg +4dgt 0.03V/A 10.00A* 0.03V/A *10A continuous Ω Ohms RANGE Accuracy 50.00Ω 0.4% rdg+ 6dgt 500.0Ω 0.2% rdg+ 3dgt 5.000kΩ, 50.00kΩ, 500.0kΩ 0.2% rdg+ 2dgt 5.000MΩ 1.0% rdg+ 3dgt 50.00MΩ 1.5% rdg+ 5dgt Open Circuit Voltage : <1.3VDC (<3VDC for 50Ω & 500Ω ranges) Temp Temperature ( & ) RANGE Accuracy* -50 TO 1000 0.3% rdg + 3dgt *K type thermocouple range & accuracy not included 36
Hz Frequency Function Sensitivity (Sine RMS) Range mv 300mV 10Hz - 125kHz 5V 2V 10Hz - 125kHz 50V 20V 10Hz - 20kHz 500V 80V 10Hz - 1kHz 1000V 300V 10Hz - 1kHz µa 500µA 10Hz - 30kHz ma 50mA 10Hz - 30kHz A 5A 10Hz - 10kHz Accuracy: 0.01% rdg + 2dgt Capacitance RANGE Accuracy* 50.00nF 0.8% rdg + 3dgt 500.0nF 0.8% rdg + 3dgt 5.000µF 1.0% rdg + 3dgt 50.00µF 2.0% rdg + 3dgt 500.0µF 3.5% rdg + 5dgt 9999µF 5.0% rdg + 5dgt Measurement range of 500.0µF manual range :50.0 to 500.0µF. Measurement range of 9999µF manual range :500 to 9999µF. *Accuracies with film capacitor or better Diode Tester Test Current Open Circuit Range Accuracy (Typical) Voltage 2.000V 1% rdg+1dgt 0.4mA <3.5 VDC 37
Model UT371/372: OPERATING MANUAL Accurate Specifications Accuracy: (a% reading + b digits), guarantee for 1 year. Operating temperature: 23 o C 5 o C Operating humidity: 80%RH Temperature Coefficient: 0.1 x (accuracy) / o C A. RPM Range Resolution Accuracy 10~99.999 r/min 100~999.99 r/min 1000~9999.9 r/min 10000~99999 r/min B. Counts 0.001 r/min 0.01 r/min 0.1 r/min 1 r/min (0.04%+2) Range Resolution Maximum input frequency 0~ 99999 1 digits 10kHz, Pulse Width 5% 20
POZIOMICA STANLEY FATMAX 1. Dokładność pomiarowa elektroniczna przy pomiarze 0 i 90 : 0,1. 2. Dokładność pomiarowa elektroniczna przy pomiarze 1 i 0,89 : 0,2. 3. Dokładność wskazań libelli 1 mm/m (0,057 ).
OBJ_DOKU-39859-001.fm Page 103 Thursday, August 14, 2014 9:32 AM Polski 103 W razie, gdy promień lasera natrafi na oko, należy natychmiast zamknąć oczy i usunąć głowę z zasięgu padania wiązki. Nie wolno dokonywać żadnych zmian ani modyfikacji urządzenia laserowego. Nie należy używać okularów do pracy z laserem jako okularów ochronnych. Okulary do pracy z laserem służą do lepszej identyfikacji plamki lub linii lasera, a nie do o- chrony przed promieniowaniem laserowym. Nie należy stosować okularów do pracy z laserem jako okularów słonecznych, ani używać ich w ruchu drogowym. Okulary do pracy z laserem nie zapewniają całkowitej ochrony przed promieniowaniem UV i utrudniają rozróżnianie kolorów. Napraw urządzenia pomiarowego powinien dokonywać jedynie wykwalifikowany personel, przy użyciu oryginalnych części zamiennych. Tylko w ten sposób można zapewnić bezpieczną eksploatację przyrządu. Nie wolno udostępniać laserowego urządzenia pomiarowego do użytkowania dzieciom. Mogą one nieumyślnie oślepić siebie lub inne osoby. Nie należy stosować tego urządzenia pomiarowego w otoczeniu zagrożonym wybuchem, w którym znajdują się łatwopalne ciecze, gazy lub pyły. W urządzeniu pomiarowym może dojść do utworzenia iskier, które mogą spowodować zapłon pyłów lub oparów. Końcówkę 15 należy trzymać z dala od przewodów lub części, znajdujących się pod napięciem. Istnieje ryzyko porażenia prądem. Opis urządzenia i jego zastosowania Proszę rozłożyć stronę z graficznym przedstawieniem urządzenia pomiarowego i pozostawić ją rozłożoną podczas czytania instrukcji obsługi. Użycie zgodne z przeznaczeniem Urządzenie pomiarowe przeznaczone jest do pomiaru odległości, długości, wysokości, odstępów, a także do obliczania powierzchni i kubatury. Urządzenie pomiarowe nadaje się do zastosowania wewnątrz pomieszczeń i na zewnątrz. Dane techniczne Cyfrowy dalmierz laserowy DLE 70 Professional Numer katalogowy 3 601 K16 60. Zakres pomiaru 0,05 70 m A) Dokładność pomiaru (typowa) ±1,5 mm B) Najmniejsze wskazanie 1mm Temperatura pracy 10 C...+50 C C) Temperatura przechowywania 20 C...+70 C Relatywna wilgotność powietrza maks. 90 % Klasa lasera 2 Typ lasera 635 nm, <1 mw Średnica plamki lasera (przy 25 C) ok. w odległości 10 m w odległości 70 m Baterie Akumulatory Żywotność baterii, ok. Pomiary pojedyncze Pomiary ciągłe (funkcja minimum/maksimum) Automatyczne wyłączanie po ok. Laser Urządzenie pomiarowe (bez pomiaru) 6mm 42 mm 4x1,5VLR03(AAA) 4 x 1,2 V HR03 (AAA) 30000 D) 5h D) 20 s 5min A) Zasięg maksymalny zależy od refleksu świetlnego obiektu pomiaru (odbicie rozproszone, nie lustrzane) i od stopnia widoczności plamki lasera (we wnętrzach, o zmroku). Przy niekorzystnych warunkach (np. pomiar w terenie odkrytym, przy silnym nasłonecznieniu), należy używać tarczy celowniczej. B) Przy niekorzystnych warunkach, jak np. silne nasłonecznienie lub słabo odbijająca powierzchnia, pomiary dokonywane są z odchyleniem do (maks.) ±10 mm na 70 m. Przy korzystnych warunkach, należy liczyć się z odchyleniem, wynoszącym ±0,05 mm/m. C) W przypadku pomiarów ciągłych (funkcja minimum/maksimum) maks. temperatura robocza wynosi +40 C. D) Z akumulatorami 1,2 V można dokonać mniejszą ilość pomiarów niż przy zastosowaniu baterii 1,5 V. Do jednoznacznej identyfikacji narzędzia pomiarowego służy numer serii 20, znajdujący się na tabliczce znamionowej. Bosch Power Tools 1 609 92A 0L8 (14.8.14)