User s manual NVS-021VPSD-HD

Podobne dokumenty
User s manual NVS-021CB

User s manual NVS-021PS

User s manual NVS-021VPS-HD

user s manual NV-002MIC

u s e r s m a n u a l NVG-031TLIB

User s manual (short) NVPT-A151VR-HD

User s manual NVPT-A122VRH

user s manual NV-RCUTC-35HD

Instrukcja obsługi. Zasilacz PoE NV-100PS Zasilacz PoE NV-1000PS/P+

user s manual NVS-1601CB

instrukcja obsługi NVRS-004DD NVRS-016DD

instrukcja obsługi NVS-001CB NVS-003UR NVS-005VD

User s manual. PoE Injector NV-1001PS/P+

User s manual NV-01SFP

u s e r s m a n u a l NV-202VIP

BLACKLIGHT SPOT 400W F

instrukcja obsługi NVPT-111VT NVPT-111VTP NVPT-414V

User s manual NVS-3004SP

bracket mounting manual instrukcja instalacji uchwytu NVB-BEH24DB

LED WASHER 30x3W WHITE IP65 F

Bracket mounting manual NVB-5100VB

user s manual NVL-3MP2812D/IR

User s manual NVPT-A121VT NVPT-A122VR

user s manual instrukcja obsługi NVB-SD6PA

user s manual instrukcja obsługi NVB-SD6CB

User s manual Instrukcja obsługi NVPT-111VTS-II NVPT-111VTP-II NVPT-111VT-II

NVB-5000JB NVB-5010JB

user s manual instrukcja obsługi NVB-SD6CA

User s manual Instrukcja obsługi NVPT-414V-II

Bracket mounting manual NVB-2040VB

user s manual NVB-4010VB

User s manual NV-108S/P+

user s manual instrukcja obsługi NVB-3000WB

Bracket mounting manual NVB-5000WB

WYŁĄCZNIK CZASOWY OUTDOOR TIMER

LED MAGIC BALL MP3 F

User s manual NV-208S/P+

user s manual instrukcja obsługi NVIP-2C5005CZ-P/GO

V-10/4RB V-16/4RB V-5SB V-TS V-CS/15A V-THSC/60 V-THS

user s manual instrukcja obsługi NVB-SD3000CB

user s manual NVAHD-1DN3101H/IR-1

user s manual NVL-2812D/IR-II NVL-358D/IRA NVL-550D/IR

instrukcja obsługi NVPT-111AVDT

user s manual instrukcja obsługi NVB-3600CB

u s e r s m a n u a l NVC-201D

user s manual NVB-3000CA

user s manual NVB-3000PA

LED PAR 56 7x10 4in1 RGBW F

Przewody elektroenergetyczne z izolacją XLPE

Power cables with XLPE insulation

Przewody elektroenergetyczne z izolacją XLPE

LED WALL WASHER 36x3W RGBW 3SC IP65 F

user s manual NV-IR60/150LED

YKXS, YKXSżo 0,6/1 kv. Kable elektroenergetyczne z izolacją XLPE. Norma IEC :2004. Konstrukcja. Zastosowanie. Właściwości

YAKXS, YAKXSżo 0,6/1 kv. Kable elektroenergetyczne z izolacją XLPE. Norma IEC :2004. Konstrukcja. Zastosowanie.

user s manual NVC-CDN3113H/IR NVC-CDN3112H/IR NVC-CDN3111H/IR NVC-CDN3110H/IR

user s manual instrukcja obsługi NVB-SD70CB

User s manual NVB-SD71FMB

LED WASHER RGB IP34 F

LED PAR 64 18x10W 4in1 CLASSIC F

LED PAR 18x10W RGBW 4in1 Aluminum single cast II ver. F

user s manual instrukcja obsługi NVIP-2C2001D-P/GO

User s manual NV-116S/P+ NV-124S/P+

LED PAR 18x10W RGBW 4in1 IP65 F

Tłumaczenie oryginalnej deklaracji ( z języka angielskiego)

User s manual NVL-358D NVL-2810D NVL-550D NVL-308D/IR NVL-358D/IR NVL-416D/IR NVL-550D/IR NVL-2812D/IR-II

POWER BANK. Owner s manual Instrukcja obsługi EN PL

NVB-IR2KIT NVB-IR3KIT

user s manual instrukcja obsługi NVH-160H/230 NVH-160H/12/24

LED PAR 36 12x3W RGBW F

instrukcja obsługi user s manual NVB-40PA

1.1. Przeznaczenie. Transformator bezpieczeństwa AWT xxx przeznaczony jest do zasilania urządzeń wymagających napięcia AC: U1 lub U2.

LED MINI DERBY 4x3W RGBW F

LED PAR 64 18x10W RGBW 4in1 IP64 PFC F

Przełączniki typu desktop seria DSP1 Desktop type switches DSP1 series

LED PAR 18x 10W RGBW 4in1 Aluminium single cast v.iii F B

POWER BANK KM0209-KM0211

instrukcja obsługi NVB-SD40W NVB-SD40CB

DM-ML, DM-FL. Auxiliary Equipment and Accessories. Damper Drives. Dimensions. Descritpion

YKXS, YKXSżo 0,6/1 kv. Kable elektroenergetyczne z izolacją XLPE. Norma IEC :2004. Konstrukcja. Zastosowanie. Właściwości

SkillGuide. Podręcznik użytkownika. Polski

YAKXS, YAKXSżo 0,6/1 kv. Kable elektroenergetyczne z izolacją XLPE. Norma IEC :2004. Konstrukcja. Zastosowanie.

Installation of EuroCert software for qualified electronic signature

USER MANUAL / INSTRUKCJA OBSŁUGI. LED Double Derby 2x10W 4in1 F

LED WALL WASHER 9x10W RGBW 4in1 DMX WIFI + ACU IP65 F a

Mouse Tracer Fiorano RF

LED PAR 64 7x10W RGBW 4in1 ABS Remote Control F

Power cables with XLPE insulation

Power cables with XLPE insulation

DEKLARACJA ZGODNOŚCI 19/10/2017, Łódź

HAPPY ANIMALS L01 HAPPY ANIMALS L03 HAPPY ANIMALS L05 HAPPY ANIMALS L07

HAPPY ANIMALS L02 HAPPY ANIMALS L04 HAPPY ANIMALS L06 HAPPY ANIMALS L08

LED PAR 56 Slim 18X3W RGB Aura F a

YKY, YKYżo 0,6/1 kv. Kable elektroenergetyczne z izolacją PVC. Norma. 10 mm² PN-HD 603 S1:3G >10 mm² IEC :2004. Konstrukcja.

short user s manual skrócona instrukcja obsługi NVIP-2DN3001H/IRH-2P/GO

LED PAR 56 7*10W RGBW 4in1 SLIM

Deklaracja zgodności

1.1. Przeznaczenie. Transformator AWT xxx przeznaczony jest do zasilania urządzeń wymagających napięcia AC: U1, U2 lub U3.

INSTRUCTION MANUAL. Strona 1

Transkrypt:

User s manual NVS-021VPSD-HD

NVS-021VPSD-HD user's manual, ver. 1.0 IMPORTANT INFORMACJE SAFEGUARDS AND WARNINGS EMC (2004/108/EC) and LVD (2006/95/EC ) Directives CE Marking Our products are manufactured to comply with the requirements of the following directives and national regulations implementing the directives: Electromagnetic compatibility EMC 2004/108/EC. Low voltage LVD 2006/95/EC with further amendment. The Directive applies to electrical equipment designed for use with a voltage rating of between 50VAC and 1000VAC as well as 75VDC and 1500VDC. WEEE 2012/19/EU Information on Disposal for Users of Waste Electrical and Electronic Equipment This appliance is marked according to the European Directive on Waste Electrical and Electronic Equipment (2012/19/EU) and further amendments. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The symbol on the product, or the documents accompanying the product, indicates that this appliance may not be treated as household waste. It shall be handed over to the applicable collection point for used up electrical and electronic equipment for recycling purpose. For more information about recycling of this product, please contact your local authorities, your household waste disposal service or the shop where you purchased the product. RoHS Directive 2011/65/EU Out of concern for human health protection and friendly environment, we assure that our products falling under RoHS Directive regulations, regarding the restriction of the use of hazardous substances in electrical and electronic equipment, have been designed and manufactured in compliance with the above mentioned regulations. Simultaneously, we claim that our products have been tested and do not contain hazardous substances whose exceeding limits could have negative impact on human health or natural environment. Information The device, as a part of professional CCTV system used for surveillance and control, is not designed for self installation in households by individuals without technical knowledge. The manufacturer is not responsible for defects and damages that result from improper or inconsistent with user s manual installation of the device in the system. All rights reserved AAT Holding S.A. 2

NVS-021VPSD-HD user's manual, ver. 1.0 SAFETY REQUIREMENTS WARNING! THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A PROPER DEVICE OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE YOURSELF WITH THE MANUAL PRIOR TO INSTALLATION AND FURTHER DEVICE OPERATION. WARNING! USER IS NOT ALLOWED TO DISASSEMBLE THE CASING AS THERE ARE NO USER- SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL MAY OPEN THE UNIT INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE PERSONNEL AND SHOULD CONFORM TO ALL LOCAL REGULATIONS WARNING! PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN PRODUCT IN USER S MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF THE PRODUCT, MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF EXCLUDING THE MANUFACTURER S RESPONSIBILITY FOR THE RESULTS OF SUCH AN ACTION. 1. Prior to undertaking any action please consult the following manual and read all the safety and operating instructions before starting the device. 2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary; 3. All the safety precautions referred to in this manual should be strictly followed, as they have a direct influence on user s safety and durability and reliability of the device; 4. All actions conducted by the servicemen and users must be accomplished in accordance with the user s manual; 5. The device should be disconnected from the system during maintenance procedures; 6. Usage of additional devices and components neither provided nor recommended by the producer is forbidden; 7. Usage of this device in an environment with high humidity (such as near swimming pools, bathtubs, in damp cellars) is forbidden; 8. Mounting the device on unstable surface or using not recommended mounts is forbidden. The device must be mounted by qualified personnel with proper authorization, in accordance with this user s manual. All rights reserved AAT Holding S.A. 3

NVS-021VPSD-HD user's manual, ver. 1.0 FEATURES 1. Features Power, Video and Data 3 in 1 Surge Protector; Protection: Baseband composite video signal (Bandwidth more than 100MHz) 12-24V ACDC power; Support analog and AHD cameras. Multifunction multilevel overvoltage protection, large max discharge current; low limiting voltage, quick reacting time, low insertion loss. 2. Typical Application Protected PTZ Camera Surge Protector NVS-021VPSD-HD Grounding Coaxial Cable UTP Cable Power Cable Surge Protector Grounding Keybord Power Supply 3. Panel Diagram of NVS-021VPSD-HD Video Input (Line) Data Input Video Output (Camera) Data Output Power Input Grounding Power Output Power LED Grounding Caution! Please make sure the connection direction is correct (IN - Line; OUT - Camera), otherwise it will cause the damage of the surge protector. Caution! For full protection of cameras, monitors and DVRs it is nessesary to use surge protector to each device. They should be installed on the both sides of line where surge could happen. All rights reserved AAT Holding S.A. 4

NVS-021VPSD-HD user's manual, ver. 1.0 SPECIFICATION 4. Specification Video Protection Power Protection Item Nominal Operational Voltage Max Continuous Operational Voltage Nominal Discharge Current(8/20us) Max Discharge Current (8/20us) Voltage Protection(10/700us) Reacting Time Inserting Loss Inserting Impedence Bandwidth Nominal Voltage Max Continuous Operational Voltage Nominal Discharge Current(8/20us) Max Discharge Current(8/20us) Limiting Voltage(8/20us) Rated Overload Current Leak Current Reacting Time Rated Operational Voltage Max Continuous Operational Voltage Nominal Discharge Current(8/20us) Description 5V 6V 5kA 10kA <20 V 1ns 0.2 db 1Ω 100MHz 24V 36V 5kA 10kA <200 V 10A 5uA 25ns 5V 6V 5kA Control Signal Protection Max Discharge Current(8/20us) Impulse Limiting Voltage(10/700us) Insulation resistance Inserting Loss Transmission Rate Reacting Time 10kA <20 V 0.4MΩ 0.5 db <2Mbps Environment Working Temperature -20-50 C Physical Properties Size(LWH) Weight Outer Shell 1ns 112mm x 64mm x 38mm 178g Aluminium, color: black All rights reserved AAT Holding S.A. 5

NVS-021VPSD-HD user's manual, ver. 1.0 INSTALLATION 5. Installation Please follow the next application steps: 1. Before inserting the protector into the system, please make sure the grounding grid reaches the specification; 2. Connect cables according to Typical Application diagram: input ports to Line, output ports to protected device using cables as short as possible; 3. Make sure the connection is correct, otherwise it will cause the damage of the surge protector; 4. Make sure the grounding cable of the surge protector is as short as possible. Notice: Manufacturer reserves the right for updating technical parameters and documentation All rights reserved AAT Holding S.A. 6

NVS-021VPSD-HD user's manual, ver. 1.0 NOTES All rights reserved AAT Holding S.A. 7

2015-11-04 JM, MK AAT Holding S.A., ul. Puławska 431, 02-801 Warsaw, Poland tel.: +48 22 546 07 00, fax: +48 22 546 07 59 www.novuscctv.com

Instrukcja obsługi NVS-021VPSD-HD

NVS-021VPSD-HD Instrukcja obsługi 1.0 UWAGI INFORMACJE I OSTRZEŻENIA Dyrektywy EMC (2004/108/EC) i LVD (2006/95/EC) Oznakowanie CE Nasze produkty spełniają wymagania zawarte w dyrektywach oraz przepisach krajowych wprowadzających dyrektywy: Kompatybilność elektromagnetyczna EMC 2004/108/EC. Niskonapięciowa LVD 2006/95/EC. Dyrektywa ma zastosowanie do sprzętu elektrycznego przeznaczonego do użytkowania przy napięciu nominalnym od 50VAC do 1000VAC oraz od 75VDC do 1500VDC. Dyrektywa WEEE 2012/19/UE Informacja dla użytkowników o pozbywaniu się urządzeń elektrycznych i elektronicznych. Niniejszy produkt został oznakowany zgodnie z Dyrektywą WEEE (2012/19/UE) oraz późniejszymi zmianami, dotyczącą zużytego sprzętu elektrycznego i elektronicznego. Zapewniając prawidłowe złomowanie przyczyniają się Państwo do ograniczenia ryzyka wystąpienia negatywnego wpływu produktu na środowisko i zdrowie ludzi, które mogłoby zaistnieć w przypadku niewłaściwej utylizacji urządzenia. Symbol umieszczony na produkcie lub dołączonych do niego dokumentach oznacza, że nasz produkt nie jest klasyfikowany jako odpad z gospodarstwa domowego. Urządzenie należy oddać do odpowiedniego punktu utylizacji odpadów w celu recyklingu. Aby uzyskać dodatkowe informacje dotyczące recyklingu niniejszego produktu należy skontaktować się z przedstawicielem władz lokalnych, dostawcą usług utylizacji odpadów lub sklepem, gdzie nabyto produkt. Dyrektywa RoHS 2011/65/UE Informacja dla użytkowników dotycząca ograniczenia użycia substancji niebezpiecznych w sprzęcie elektrycznym i elektronicznym. W trosce o ochronę zdrowia ludzi oraz przyjazne środowisko zapewniamy, że nasze produkty podlegające przepisom dyrektywy RoHS, dotyczącej użycia substancji niebezpiecznych w sprzęcie elektrycznym i elektronicznym, zostały zaprojektowane i wyprodukowane zgodnie z wymaganiami tej dyrektywy. Jednocześnie zapewniamy, że nasze produkty zostały przetestowane i nie zawierają substancji niebezpiecznych w ilościach mogących niekorzystnie wpływać na zdrowie człowieka lub środowisko naturalne. Wszelkie prawa zastrzeżone AAT Holding S.A. 2

NVS-021VPSD-HD Instrukcja obsługi 1.0 WARUNKI BEZPIECZEŃSTWA Informacja Urządzenie, jako element profesjonalnego systemu telewizji dozorowej służącego do nadzoru i kontroli, nie jest przeznaczone do samodzielnego montażu w gospodarstwach domowych przez osoby nie posiadające specjalistycznej wiedzy. Producent urządzenia nie ponosi odpowiedzialności za wady i uszkodzenia wynikające z niewłaściwej lub niezgodnej z instrukcją obsługi instalacji urządzenia w systemie. UWAGA! ZNAJOMOŚĆ NINIEJSZEJ INSTRUKCJI JEST NIEZBĘDNYM WARUNKIEM PRAWIDŁOWEJ EKSPLOATACJI URZĄDZENIA. PROSIMY O ZAPOZNANIE SIĘ Z NIMĄ PRZED PRZYSTĄPIENIEM DO INSTALACJI I OBSŁUGI URZĄDZENIA. UWAGA! NIE WOLNO DOKONYWAĆ ŻADNYCH SAMODZIELNYCH NAPRAW. WSZYSTKIE NAPRAWY MOGĄ BYĆ REALIZOWANE JEDYNIE PRZEZ WYKWALIFIKOWANYCH PRACOWNIKÓW SERWISU. 1. Przed zainstalowaniem i rozpoczęciem eksploatacji należy dokładnie zapoznać się z niniejszą instrukcją obsługi i zawartymi w niej wymogami bezpieczeństwa; 2. Uprasza się o zachowanie instrukcji na czas eksploatacji urządzenia na wypadek konieczności odniesienia się do zawartych w niej treści; 3. Należy skrupulatnie przestrzegać wymogów bezpieczeństwa opisanych w instrukcji, gdyż mają one bezpośredni wpływ na bezpieczeństwo użytkowników i trwałość oraz niezawodność urządzenia; 4. Wszystkie czynności wykonywane przez instalatorów i użytkowników muszą być realizowane zgodnie z opisem zawartym w instrukcji; 5. W czasie czynności konserwatorskich urządzenie musi być odłączone od systemu; 6. Nie wolno stosować żadnych dodatkowych urządzeń lub podzespołów nie przewidzianych i nie zalecanych przez producenta; 7. Nie wolno używać urządzeń w środowisku o dużej wilgotności (np. w pobliżu basenów, wanien, w wilgotnych piwnicach); 8. Nie wolno umieszczać urządzeń na niestabilnych powierzchniach. Urządzenia muszą być instalowane przez wykwalifikowany personel o odpowiednich uprawnieniach według zaleceń podanych w niniejszej instrukcji; Przed wykonaniem czynności, która nie jest przewidziana dla danego Produktu w instrukcji obsługi, innych dokumentach dołączonych do Produktu lub nie wynika ze zwykłego przeznaczenia Produktu, należy, pod rygorem wyłączenia odpowiedzialności Producenta za następstwa takiej czynności, skontaktować się z Producentem. Wszelkie prawa zastrzeżone AAT Holding S.A. 3

NVS-021VPSD-HD Instrukcja obsługi 1.0 CHARAKTERYSTYKA OGÓLNA 1. Charakterystyka ogólna Ogranicznik przepięć w torze wizyjnym, danych i zasilania; Zabezpieczenia: Pasmo sygnału wizyjnego 100 MHz, Zasilanie 12-24 VAC/DC Dedykowany do kamer analogowych jak i AHD. 2. Typowa aplikacja Zabezpieczana Kamera PTZ Ogranicznik przepięć NVS-021VPSD-HD Uziom Przewód Koncentryczny Przewód Danych - Skrętka Przewód Zasilania Ogranicznik przepięć Uziom Klawiatura Zasilacz 3. Opis złącz Ogranicznika napięć NVS-021VPSD-HD Wejście wideo (Linia) Wejście danych Wyjście wideo (Kamera) Wyjście danych Wejście zasilania Uziom Wyjście zasilania Dioda LED zasilania Uziom Uwaga! Proszę zwrócić szczególną uwagę, na poprawne podpięcie przewodów wejściowych (biegnących od linii, w której może nastąpić przepięcie) i wyjściowych (biegnących do zabezpieczanego urządzenia). Zamienienie kierunku podpięcia (wejścia z wyjściem) spowodowuje uszkodzenie urządzenia. Uwaga! W celu pełnej ochrony przeciwprzepięciowej zarówno kamer jak i rejestratorów lub monitorów, wymagane jest użycie ogranicznika przepięć do każdego urządzenia. Ograniczniki należy zainstalować po obu stronach linii, w której może dojść do przepięcia. Wszelkie prawa zastrzeżone AAT Holding S.A. 4

NVS-021VPSD-HD Instrukcja obsługi 1.0 DANE TECHNICZNE 4. Dane techniczne Zabezpieczenie toru wideo Zabezpieczenie toru zasilania Zabezpieczenie toru danych Funkcja Napięcie nominalne Maksymalne ciągłe napięcie Nominalny prąd wyładowczy (8/20us) Maksymalny prąd wyładowczy (8/20us) Napięcie protekcji (10/700us) Czas reakcji Tłumienność wtrąceniowa Impedancja wtrąceniowa Pasmo przenoszenia Napięcie nominalne Maksymalne ciągłe napięcie Nominalny prąd wyładowczy (8/20us) Maksymalny prąd wyładowczy (8/20us) Napięcie protekcji (8/20us) Prąd przeciążenia Prąd upływu Czas reakcji Napięcie nominalne Maksymalne ciągłe napięcie Nominalny prąd wyładowczy (8/20us) Maksymalny prąd wyładowczy (8/20us) Napięcie protekcji (10/700us) Rezystancja Tłumienność wtrąceniowa Prędkość transmisji Czas reakcji Opis 5V 6V 5kA 10kA <20 V 1ns 0.2 db 1Ω 100MHz 24V 36V 5kA 10kA <200 V 10A 5uA 25ns 5V 6V 5kA 10kA <20 V 0.4MΩ 0.5 db <2Mbps Środowisko Temperatura Pracy -20 ~ 50 C Wymiary Rozmiar Masa Obudowa 1ns 112mm x 64mm x 38mm 178g Aluminium, kolor czarny Wszelkie prawa zastrzeżone AAT Holding S.A. 5

NVS-021VPSD-HD Instrukcja obsługi 1.0 INSTALACJA 5. Instalacja Proszę postępować zgodnie z poniższymi krokami: 1. Przed instalacją ogranicznika przepięć, należy upewnić się, że uziom jest zgodny ze specyfikacją; 2. Podłączyć przewody, mając na uwadze poprawne podłączenie przedstawione na schemacie typowej aplikacji. Do złącz wejściowych należy podpiąć przewody biegnące od linii, w której może nastąpić przepięcie. Do złącz wyjściowych należy podpiąć zabezpieczane urządzenie, mając na uwadze by przewody łączące były możliwie krótkie. 3. Proszę sprawdzić połączenia. Odwrotne podpięcie przewodów spowoduje uszkodzenie urządzenia. 4. Proszę upewnić się, że przewód uziemiający jest krótki jak to możliwe. Uwaga! Producent zastrzega sobie możliwość wystąpienia błędów w druku oraz zmian parametrów technicznych bez uprzedniego powiadomienia. Wszelkie prawa zastrzeżone AAT Holding S.A. 6

NVS-021VPSD-HD Instrukcja obsługi 1.0 NOTATKI Wszelkie prawa zastrzeżone AAT Holding S.A. 7

2015-11-04 JM, MK AAT Holding S.A., ul. Puławska 431, 02-801 Warszawa, Polska tel.: 22 546 07 00, faks: 22 546 07 59 www.novuscctv.com