DYNAMIKA DOPŁYWU ŚCIEKÓW DO OCZYSZCZALNI W GŁOGOWIE MAŁOPOLSKIM DYNAMICS FLOW TO SEWAGE TREATMENT PLANT IN GŁOGÓW MAŁOPOLSKI

Podobne dokumenty
NIEDOCIĄŻENIA HYDRAULICZNE PRZYDOMOWYCH OCZYSZCZALNI ŚCIEKÓW UNDERLOADING OF HYDRAULIC IN DOMESTIC SEWAGE TREATMENT PLANT

OCENA DZIAŁANIA OCZYSZCZALNI ŚCIEKÓW TYPU SBR W STERKOWCU-ZAJAZIE

BILANS ŚCIEKÓW DOPŁYWAJĄCYCH I DOWOŻONYCH DO OCZYSZCZALNI NA PRZYKŁADZIE WYBRANEGO OBIEKTU

ILOŚĆ DOPŁYWAJĄCYCH ŚCIEKÓW DO OCZYSZCZALNI SBR BIOVAC W KSIĄŻU WIELKIM W LATACH

ILOŚĆ ŚCIEKÓW ORAZ WIELKOŚĆ ZANIECZYSZCZEŃ ODPROWADZANYCH Z WYBRANYCH PODMIOTÓW GOSPODARCZYCH Z TERENU GMINY MIELEC

WPŁYW OPADÓW ATMOSFERYCZNYCH NA TEMPERATURĘ ORAZ OBJĘTOŚĆ ŚCIEKÓW W MAŁYM SYSTEMIE KANALIZACYJNYM

CHARAKTERYSTYKA ZUŻYCIA WODY W SYSTEMACH WODOCIĄGOWYCH WILKÓW I BOREK W GMINIE GŁOGÓW

Ocena pracy oczyszczalni ścieków w Bielsku-Białej w latach An evaluation of sewage treatment plant in Bielsko-Biała in the years

ŚREDNIE ZUŻYCIE ZIMNEJ I CIEPŁEJ WODY W BUDYNKACH WIELORODZINNYCH AVERAGE CONSUMPTION OF WATER COLD AND WARM IN THE MULTIFAMILY BUILDINGS

ANALIZA ZMIENNOŚCI DOPŁYWU ŚCIEKÓW DO OCZYSZCZALNI DLA AGLOMERACJI DĘBICA

EWA OGIOŁDA *, IRENEUSZ NOWOGOŃSKI *, RENATA KŁONOWSKA ** CHARAKTERYSTYKA ZUŻYCIA WODY W SYSTEMACH WODOCIĄGOWYCH TURÓW I SERBY W GMINIE GŁOGÓW

USUWANIE ZWIĄZKÓW BIOGENNYCH W PRZYDOMOWYCH OCZYSZCZALNIACH ŚCIEKÓW TYPU TURBOJET I BIOCOMPACT

POZYSKIWANIE OSADU NADMIERNEGO W STANDARDOWYM UKŁADZIE STEROWANIA OCZYSZCZALNIĄ ŚCIEKÓW

EFEKTYWNOŚĆ PRACY OCZYSZCZALNI ŚCIEKÓW W KOŁACZYCACH

Struktura zużycia wody w budynkach jednorodzinnych

Ekonometryczna analiza popytu na wodę

ŁADUNKI ZANIECZYSZCZEŃ CHARAKTERYZUJĄCE ŚCIEKI POCHODZĄCE Z BUDYNKÓW SZKOLNYCH NA TERENACH WIEJSKICH

UNIESZKODLIWIANIE ŚCIEKÓW Z OBIEKTÓW UŻYTECZNOŚCI PUBLICZNEJ NA TERENACH NIEZURBANIZOWANYCH

STAN INFRASTRUKTURY WODOCIĄGOWEJ W WYBRANYCH MIASTACH DOLINY SANU WATER INFRASTRUCTURE IN THE CHOSEN CITIES IN THE SAN VALLEY

OCENA PRACY OCZYSZCZALNI ŚCIEKÓW W WADOWICACH PRZED MODERNIZACJĄ THE ASSESSMENT OF WORKING SEWAGE TREATMENT PLANT AT WADOWICE BEFORE THE MODERNIZATION

ANALIZA ILOŚCI ŚCIEKÓW ODPŁYWAJĄCYCH Z AGLOMERACJI KANALIZACYJNEJ W SANOKU

OCENA SKUTECZNOŚCI USUWANIA ZANIECZYSZCZEŃ W OCZYSZCZALNI ŚCIEKÓW W TARNOWIE

ANALIZA PRZEPŁYWÓW W INSTALACJACH WODOCIĄGOWYCH W OBIEKTACH HOTELOWYCH

ANALIZA NIEZAWODNOŚCI FUNKCJONOWANIA OCZYSZCZALNI BIOBLOK PS-50 Z ZASTOSOWANIEM METODY WEIBULLA

ACTA UNIVERSITATIS LODZIENSIS. WIELOLETNIA ZMIENNOŚĆ WYSTĘPOWANIA BURZ W SZCZECINIE, ŁODZI, KRAKOWIE I NA KASPROWYM WIERCHU W LATAm

WPŁYW ZANIECZYSZCZEŃ ODPROWADZANYCH Z UBOJNI TRZODY CHLEWNEJ ORAZ MASARNI NA JAKOŚĆ ŚCIEKÓW DOPŁYWAJĄCYCH DO OCZYSZCZALNI

ROZWÓJ WYPOSAŻENIA OBSZARÓW WIEJSKICH W WYBRANE URZĄDZENIA SIECIOWE DEVELOPMENT OF GRID FACILITIES IN RURAL AREAS SUMMARY

WIELKOŚĆ ZUŻYCIA WODY PRZEZ UŻYTKOWNIKÓW WODOCIĄGU W JORDANOWIE AMOUNT OF WATER CONSUMPTION BY WATERWORKS USERS IN JORDANÓW

ANALIZA ZMIENNOŚCI STĘŻENIA JONÓW CHROMU W ŚCIEKACH DOPŁYWAJĄCYCH DO ZBIORCZEJ OCZYSZCZALNI W NOWYM TARGU

ANALIZA ZMNIEJSZANIA WYBRANYCH ZANIECZYSZCZEŃ W ŚCIEKACH BYTOWYCH NA PRZYKŁADZIE OCZYSZCZALNI W NOWYM ŻMIGRODZIE

SPITSBERGEN HORNSUND

GOSPODAROWANIE NIECZYSTOŚCIAMI CIEKŁYMI W POLSCE

Włodzimierz MIERNIK Dariusz MŁYŃSKI

JEDNOSTKOWE ODPŁYWY ŚCIEKÓW Z KANALIZACJI WIEJSKIEJ W GMINIE KOSZYCE

FINANSOWANIE INWESTYCJI INFRASTRUKTURALNYCH W GMINACH WIEJSKICH NA PRZYKŁADZIE GMINY SPYTKOWICE

SPITSBERGEN HORNSUND

DZIAŁALNOŚĆ GOSPODARCZA W ASPEKCIE TYPÓW FUNKCJONALNYCH GMIN GÓRSKICH

SPITSBERGEN HORNSUND

SPITSBERGEN HORNSUND

22 MARZEC ŚWIATOWY DZIEŃ WODY. Przedsiębiorstwo Wodociągów i Kanalizacji Sp. z o.o. w Tarnowskich Górach

OCENA PRACY OCZYSZCZALNI ŚCIEKÓW W ŻYWCU PO WYKONANEJ ROZBUDOWIE I MODERNIZACJI

ZMIENNOŚĆ JEDNOSTKOWEGO ZUŻYCIA WODY PRZEZ MIESZKAŃCÓW OLKUSZA VARIABILITY OF THE UNITARY AVERAGE DAILY WATER CONSUMPTION BY OLKUSZNIAN MAN

JEDNOSTKOWE ZUŻYCIE WODY W GOSPODARSTWIE DOMOWYM W 8-LETNIM OKRESIE OBSERWACJI

Zmienność zużycia wody w gospodarstwach wiejskich w okresie wielolecia. Jan Pawełek, Tomasz Bergel, Olga Woyciechowska

WIELKOŚĆ I NIERÓWNOMIERNOŚĆ POBORU WODY PRZEZ POJEDYNCZE GOSPODARSTWA WIEJSKIE

Metryki wskaźników dla działania 3.6 Wsparcie rozwoju systemów oczyszczania ścieków

ANALIZA EKONOMICZNA ZASTOSOWANIA DUALNEJ INSTALACJI KANALIZACYJNEJ W PRZYDOMOWYCH OCZYSZCZALNIACH ŚCIEKÓW

Ankieta dotycząca gospodarki wodno-ściekowej w 2006 r.

KOSZTY UŻYTKOWANIA MASZYN W STRUKTURZE KOSZTÓW PRODUKCJI ROŚLINNEJ W WYBRANYM PRZEDSIĘBIORSTWIE ROLNICZYM

UCHWAŁA NR LVI/555/14 RADY MIEJSKIEJ W STASZOWIE. z dnia 30 października 2014 r.

WIELOKRYTERIALNY DOBÓR ROZTRZĄSACZY OBORNIKA

WPŁYW TECHNICZNEGO UZBROJENIA PROCESU PRACY NA NADWYŻKĘ BEZPOŚREDNIĄ W GOSPODARSTWACH RODZINNYCH

OKRESY UŻYTKOWANIA I WYKORZYSTANIE ŚRODKÓW ENERGETYCZNYCH W GOSPODARSTWACH RODZINNYCH

Ewa Rauba*, Krystyna Rauba**

STORMWATER 2018, Gdańsk

SPITSBERGEN HORNSUND

WPŁYW TEMPERATURY POWIETRZA NA TEMPERATURĘ ŚCIEKÓW W KANALIZACJI I REAKTORZE BIOLOGICZNYM

SPITSBERGEN HORNSUND

Zachowania odbiorców. Grupa taryfowa G

BADANIA ZRÓŻNICOWANIA RYZYKA WYPADKÓW PRZY PRACY NA PRZYKŁADZIE ANALIZY STATYSTYKI WYPADKÓW DLA BRANŻY GÓRNICTWA I POLSKI

ZMIENNOŚĆ TEMPERATURY ŚCIEKÓW W MAŁYCH SYSTEMACH KANALIZACYJNYCH THE VARIABILITY OF SEWAGE TEMPERATURE IN SMALL SEWER SYSTEMS

ANALIZA ISTNIEJĄCYCH DZIAŁEK SIEDLISKOWYCH NA TERENIE GMINY DOMANIÓW

Uwarunkowania prawne obejmujące zagadnienia dotyczące wprowadzania ścieków komunalnych do środowiska

OCENA NIEZAWODNOŚCI DZIAŁANIA OCZYSZCZALNI ŚCIEKÓW DLA GMINY TUCHÓW

yszczalni w Szebniach

Definicja i wzór wyliczenia efektów ekologicznych związanych z gospodarką ściekową. [na podstawie wytycznych NFOŚiGW]

Nakłady na środki trwałe służące ochronie środowiska i gospodarce wodnej w Polsce w 2012 r.

OCENA NIEZAWODNOŚCI USUWANIA ZWIĄZKÓW BIOGENNYCH W OCZYSZCZALNI ŚCIEKÓW METODĄ WEIBULLA

OCENA DZIAŁANIA OCZYSZCZALNI ŚCIEKÓW W HACZOWIE PRZED I PO MODERNIZACJI

WYZNACZANIE OBCIĄŻEŃ SZCZYTOWYCH W WIEJSKICH SIECIACH ELEKTROENERGETYCZNYCH

WPŁYW TEMPERATURY W POMIESZCZENIACH POMOCNICZYCH NA BILANS CIEPŁA W BUDYNKACH DLA BYDŁA

ANALIZA WYPOSAŻENIA GOSPODARSTW EKOLOGICZNYCH W CIĄGNIKI ROLNICZE

OCENA PARAMETRÓW JAKOŚCI ENERGII ELEKTRYCZNEJ DOSTARCZANEJ ODBIORCOM WIEJSKIM NA PODSTAWIE WYNIKÓW BADAŃ

Uporządkowanie gospodarki. wodno-ściekowej W Gminie Wadowice

Analiza popytu na wodę miejskich gospodarstw domowych w Polsce w latach

Część A: Wodociągi dr inż. Małgorzata Kutyłowska dr inż. Aleksandra Sambor

WYKORZYSTANIE MODELI TAKAGI SUGENO DO KRÓTKOTERMINOWEGO PROGNOZOWANIA ZAPOTRZEBOWANIA NA ENERGIĘ ELEKTRYCZNĄ ODBIORCÓW WIEJSKICH

PROGNOZOWANIE CENY OGÓRKA SZKLARNIOWEGO ZA POMOCĄ SIECI NEURONOWYCH

STRUKTURA ZUŻYCIA ZIMNEJ I CIEPŁEJ WODY W GOSPODARSTWIE JEDNORODZINNYM

KOMPUTEROWE MODELOWANIE SIECI WODOCIĄGOWYCH JAKO NARZĘDZIE DO ANALIZY PRĘDKOŚCI PRZEPŁYWU WODY

PLAN ROZWOJU I MODERNIZACJI URZĄDZEŃ WODOCIĄGOWYCH I URZĄDZEŃ KANALIZACYJNYCH ORAZ POZOSTAŁE INWESTYCJE NA LATA

Tendencje zużycia energii elektrycznej wybranych obszarów zasilania

Uporządkowanie gospodarki ściekowej w miejscowościach Biała Niżna i Stróże

PODAŻ CIĄGNIKÓW I KOMBAJNÓW ZBOŻOWYCH W POLSCE W LATACH

SPITSBERGEN HORNSUND

Uchwała Nr IX/71/2015 Rady Miejskiej w Kalwarii Zebrzydowskiej z dnia 17 września 2015r.

Evolution of water meters selection on the background of water consumption in multidwelling buildings

ANALIZA EFEKTYWNOŚCI USUWANIA ZANIECZYSZCZEŃ ZE ŚCIEKÓW W OCZYSZCZALNI W WOLI DALSZEJ K/ŁAŃCUTA

OCENA FUNKCJONOWANIA OCZYSZCZALNI ŚCIEKÓW W DYNOWIE THE EVALUATION OF WASTEWATER TREATMENT PLANT IN DYNÓW

Projekt CCI 2007/PL/161/PR/007,,Modernizacja i rozbudowa systemu gospodarki wodno-ściekowej miasta Nowego Sącza z przyległymi terenami gmin sąsiednich

PONIEDZIAŁEK WTOREK

UCHWAŁA NR XXX/254/13 RADY MIEJSKIEJ W GRODKOWIE. z dnia 29 maja 2013 r.

SPITSBERGEN HORNSUND

SPITSBERGEN HORNSUND

Inżynier środowiska stale potrzebny

OCENA SKUTECZNOŚCI PRACY OCZYSZCZALNI ŚCIEKÓW W JAŚLE EVAULATION OF EFFICENCY OF SEWAGE TREATMENT PLANT IN JASŁO

OCENA SKUTECZNOŚCI ORAZ STABILNOŚCI PRACY OCZYSZCZALNI ŚCIEKÓW W ZABAJCE

UCHWAŁA Nr XXXIV/213/2009 Rady Miejskiej Pieszyc z dnia 28 sierpnia 2009 roku

OCENA SKUTECZNOŚCI OCZYSZCZANIA ŚCIEKÓW W OCZYSZCZALNI ŚCIEKÓW W NOWYM SĄCZU-WIELOPOLU

Transkrypt:

INFRASTRUKTURA I EKOLOGIA TERENÓW WIEJSKICH INFRASTRUCTURE AND EKOLOGY OF RURAL AREAS Nr 2/2007, POLSKA AKADEMIA NAUK, Oddział w Krakowie, s. 103 109 Komisja Technicznej Infrastruktury Wsi Dynamika dopływu ścieków Piotr Bugajski DYNAMIKA DOPŁYWU ŚCIEKÓW DO OCZYSZCZALNI W GŁOGOWIE MAŁOPOLSKIM DYNAMICS FLOW TO SEWAGE TREATMENT PLANT IN GŁOGÓW MAŁOPOLSKI Streszczenie W artykule przedstawiono ilość dopływających ścieków oraz częstość występowania charakterystycznych dopływów ścieków do oczyszczalni w Głogowie Małopolskim. Okres badań objął trzy lata 2003 2005. W okresie tym pomiarem objęto dzienne dopływy ścieków. Na podstawie zarejestrowanych dopływów określono ilość dopływających ścieków w poszczególnych dniach tygodnia. W roku 2003 dopływ ścieków w kolejnych dniach tygodnia był równomierny, to znaczy w żadnym z dni tygodnia dopływ ścieków był na wyraźnie wyższym lub niższym poziomie. W analizowanym roku dopływy wahały się od 626,9 m 3 d -1 do 703,1 m 3 d -1. Dopływ średni wyniósł 657,3 m 3 d -1. W kolejnym roku 2004 odnotowano znaczy wzrost dopływających ścieków o ponad 100% w stosunku do roku 2003. Wzrost ten spowodowany był rozbudową sieci kanalizacyjnej oraz podłączeniem kolejnych gospodarstw do kolektorów kanalizacyjnych. W roku 2004 również nie odnotowano dużych wahań dopływu ścieków w poszczególnych dniach tygodnia. Średni dopływ wyniósł w tym okresie 1317,2 m 3 d -1. Większą nierównomierność dopływu ścieków odnotowano w roku 2005. Najmniej ścieków dopływało w środy 1348,3 m 3 d -1, natomiast największy w niedziele 1548,6 m 3 d -1. Średni dopływ był wyższy w roku 2005 w porównaniu z rokiem poprzednim o blisko 13% i wyniósł 1485,4 m 3 d -1. Kolejnym etapem analizy wyników było określenie częstości występowania określonych dopływów ścieków i prawdopodobieństwa ich pojawiania się. Z przedstawionej analizy częstości dopływów wynika, że najczęściej pojawiające się dopływy ścieków mieszczą się w przedziałach 1100 m 3 d -1 a 1200 m 3 d -1 oraz pomiędzy 1200 m 3 d -1 a 1300 m 3 d -1. Prawdopodobieństwo odczytane z dystrybuanty empirycznej pojawienia się dopływu w tych 103

Piotr Bugajski granicach wraz z wyższymi wynosi około 50%. W przedmiotowej oczyszczalni ścieków zdarzały się incydentalnie dopływy ścieków znacznie przekraczające dopływy średnie. Wynosiły one ponad 2700 m 3 d -1. Jednak prawdopodobieństwo pojawienia się tak wysokich dopływów jest minimalne (0,1%). Słowa kluczowe: ilość ścieków, nierównomierność dopływu ścieków Summary In a article presented amount in flow sewage and frequency occur of characteristic in flow sewage to sewage treatment plant in Głogow Malopolski. The period of research took there years 2003 2005. In this time was measure days in flow sewage. On the basis of register in flow described amount in flow sewage in selected days of week. In 2003 supply sewage in days week was even, this is non of days in flow of sewage was bigger or lower content. In analysis year in flow was from 626,9 m 3 d -1 to 703,1 m 3 d -1. Middle in flow was 657,3 m 3 d -1. In next year 2004 keep a recorded considerable growth in flow sewage on over 100% with relation to year 2003. This growth cause was extending sewage system and connected next households to sewage system. In 2004 year also non of big of difference in flow sewage in selected days of week. Middle in flow in this time was 1317,2 m 3 d -1. Bigger unevenness in flow wrote down in 2005 year. The smaller sewage in flow in wednesdays 1348,3 m 3 d -1, however the biggest in sundays 1548,6 m 3 d -1. Middle in flow was bigger in 2005 year them previous year almost 13% and was 1485,4 m 3 d -1. For need exploitation and if need be modernization sewage-system very important is indicate frequency of appearance specific flow to sewer and probability of appear. Analysis of frequency of appearance is very useful statistic of estimate for interpretation measurement of result. Especially as measure is irregular. In article so that frequency of appearance specific flow to sewer and foresee probability of appear drew up histogram (Fig. 2). On histogram can be read frequency of appearance concrete flow to and probability of appear with higher values. The number class arrange on 29 and class span-range arrange on 100. Next stage analysis was qualification of frequency occur specifics in flows and probability theirs appear. From present analysis of frequency is result that the most often appears in flow are between 1100 m 3 d -1 1200 m 3 d -1 and between 1200 m 3 d -1 1300 m 3 d -1. Probability of result from empirical curve occur in flow in this limit is about 50%. In sewage treatment plant happened incident in flow of sewage of crossing middle in flows. Take was over 2700 m 3 d -1. However probability occur this big in flows is minimal. Key words: amount sewage, irregular flow to sewage 104

Dynamika dopływu ścieków WSTĘP Obecnie w Polsce projektując lub modernizując sieć kanalizacyjną przyjmuje się ilość odpływających ścieków z gospodarstw domowych na podstawie ilości zużywanej wody przez mieszkańców. Niestety, często zamiast przyjmować faktyczną ilość zużywanej wody projektanci w większości przypadków przyjmują ilość wody zakładaną w projekcie. Przyjmowanie najczęściej 150 dm 3 zużywanej wody przez mieszkańca w ciągu doby jest ilością zbyt dużą, co wskazują doniesienia autorów zajmujących się gospodarką wodno-ściekową [Bugajski, Kaczor 2005; Chotkowski, Lis 2006; Kluba 2006]. Szczególnie duże różnice pomiędzy wartością projektowaną a ilością wody faktycznie zużywaną odnosi się do terenów wiejskich, gdzie ludność nie jest przyzwyczajona do rozrzutnego korzystania z wody. Nawyki związane z oszczędnością, braki pełnego wyposażenia budynków w instalację wodno-kanalizacyjną są głównymi przyczynami niskiego poboru wody przez mieszkańców. Dodatkowymi czynnikami wpływającymi na zmniejszenie ilości zużywanej wody w Polsce w ostatnich latach to jej stale rosnąca cena, montaż wodomierzy oraz instalacja urządzeń wodooszczędnych w mieszkaniach (pralki, zmywarki do naczyń, toalety). Przewymiarowanie sieci kanalizacyjnych skutkuje przede wszystkim zbyt małą ilością ścieków dopływających na oczyszczalnię. W ten sposób wiele oczyszczalni ścieków na terenach wiejskich jest niedociążona hydraulicznie. Eksploatatorzy tych obiektów często wyrażają opinię o braku ścieków dopływających do oczyszczalni. Brak odpowiedniej ilości ścieków może wpływać na zakłócenia pracy oczyszczalni. Procesy zachodzące w oczyszczalniach ścieków, aby były skuteczne, muszą zachodzić przy odpowiedniej dawce ścieków oraz odpowiedniej ilości zanieczyszczeń w nich zawartych. CEL PRACY ORAZ ZAKRES BADAŃ Celem badań było określenie objętości oraz nierównomierności dopływających ścieków w okresie 2003 do 2005 roku. Obiektem, do którego dopływają ścieki to zbiorcza oczyszczalnia ścieków w Głogowie Małopolskim odbierająca ścieki z 1985 gospodarstw domowych. W artykule przeanalizowano dopływy w poszczególnych dniach tygodnia w ciągu trzech lat. W roku 2004 ilość dopływających ścieków znacznie się zwiększyła z powodu rozbudowy i podłączenia kolejnych mieszkańców do sieci kanalizacyjnej. Na bazie wyników badań przeprowadzono obliczenia statystyczne, pozwalające na określenie częstości występowania określonych dopływów ścieków oraz prawdopodobieństwa ich wystąpienia. 105

Piotr Bugajski ANALIZA WYNIKÓW BADAŃ Na rysunku 1 przedstawiono dopływy ścieków w poszczególnych dniach tygodnia w latach 2003 2005. Średni dopływ do oczyszczalni w roku 2003 wyniósł 657,3 m 3 d -1. Nie odnotowano dużych wahań dopływów ścieków w poszczególnych dniach tygodnia do oczyszczalni w 2003. Dopływy w tym okresie wahały się od 626,9 m 3 d -1 w niedziele do 703,1 m 3 d -1 w soboty. Średni dopływ ścieków do przedmiotowej oczyszczalni ścieków w analizowanym roku wyniósł 657,3 m 3 d -1. W kolejnym roku 2004 odnotowano znaczny wzrost dopływających ścieków, który wyniósł ponad 100% w stosunku do roku 2003. Wzrost ten Q śr.d. [m 3 d -1 ] 1600 1400 1200 1000 800 600 400 200 0 poniedziałek wtorek środa czwartek piątek Średni dobowy dopływ ścieków sobota niedziela 2003rok 2004rok 2005rok Rysunek 1. Ilość dopływających ścieków w poszczególnych dniach tygodnia w wieloleciu 2003-2005 Figure 1. Volume of sewage flowing in individuals week days in 2003-2005 years spowodowany jest podłączeniem do sieci kanalizacyjnej kolejnych gospodarstw domowych. Również w tym okresie nie odnotowano znaczących wahań dopływów średnio-dobowych w poszczególnych dniach tygodnia. Ilości dopływających ścieków do oczyszczalni mieściły się w granicach od 1269,1 m 3 d -1 we wtorki do 1347,3 m 3 d -1 w środy. Średni dopływ ścieków w roku 2004 wyniósł 1317,2 m 3 d -1. Kolejny rok 2005 przyniósł ponownie wzrost dopływających ścieków w porównaniu do roku 2004 o około 13%. Był to niewielki przyrost dopływających ścieków w porównaniu z okresem poprzednim. Obecnie dopływ 106

Dynamika dopływu ścieków do oczyszczalni kształtuje się na średnim poziomie, tak jak w roku 2005, czyli dopływa około 14500 m 3 d -1. W roku 2005 odnotowano nierównomierność dopływających ścieków do oczyszczalni w porównaniu z latami 2003 i 2004. Najmniejszy średni dopływ był w środy i wyniósł 1348,3 m 3 d -1, natomiast największy w niedziele i wyniósł 1548,6 m 3 d -1. Różnica pomiędzy dopływami minimalnymi a maksymalnymi w poszczególnych dniach tygodnia wyniosła ponad 200 m 3 d -1. Dla potrzeb eksploatacji, a także ewentualnej modernizacji systemów odprowadzania i oczyszczania ścieków, istotne jest określenie częstości występowania określonych dopływów ścieków i prawdopodobieństwa ich pojawiania się [Henze et. al. 2000; Poradnik eksploatatora... 1997]. Analiza częstości występowania jest bardzo przydatnym narzędziem statystycznym dla interpretacji wyników pomiarowych, wykonywanych zarówno regularnie jak i nieregularnie [Kaczor 2000]. Aby określić częstość pojawienia się danego dopływu oraz przewidzieć prawdopodobieństwo jego pojawienia się sporządzono histogram (rys. 2). Na histogramie można odczytać częstość pojawienia się konkretnego częstość względna [%] 10,00 9,00 8,00 7,00 6,00 5,00 4,00 3,00 2,00 1,00 0,00 Histogram częstości w zględnej empiryczna funkcja praw dopodobieństwa 200<x<=300 300<x<=400 400<x<=500 500<x<=600 600<x<=700 700<x<=800 800<x<=900 900<x<=1000 1000<x<=1100 1100<x<=1200 1200<x<=1300 1300<x<=1400 1400<x<=1500 1500<x<=1600 1600<x<=1700 1700<x<=1800 1800<x<=1900 1900<x<=2000 2000<x<=2100 2100<x<=2200 2200<x<=2300 2300<x<=2400 2400<x<=2500 2500<x<=2600 2600<x<=2700 2700<x<=2800 2800<x<=2900 2900<x<=3000 3000<x<=3100 100 90 80 70 60 50 40 30 20 10 0 prawdopodobieństwo [%] Ilość dopływających ścieków [m 3 d -1 ] Rysunek 2. Histogram częstości względnej występowania ilości dopływających ścieków w poszczególnych przedziałach wraz z empiryczną funkcją prawdopodobieństwa przewyższenia Figure 2. Histogram relative frequency to occur amount of sewage in individuals ranges with empirical function probability outstrip 107

Piotr Bugajski przepływu oraz prawdopodobieństwo jego wystąpienia wraz w wartościami wyższymi. Liczbę klas ustalono na 29, a rozpiętość przedziału klasowego ustalono na 100Q śr.d. Po ustaleniu granic klas zliczono poszczególne wartości znajdujące się w przedziałach poszczególnych klas. W wyniku otrzymano szereg, w którym do danego przedziału przypisano ilość obserwacji, zwaną liczebnością klasy. Z przedstawionego rysunku 2 wynika, że najczęściej pojawiające się dopływy ścieków mieszczą się w przedziałach 1100 m 3 d -1 a 1200 m 3 d -1 oraz pomiędzy 1200 m 3 d -1 a 1300 m 3 d -1. Prawdopodobieństwo odczytane z empirycznej funkcji prawdopodobieństwa pojawienia się dopływu w tych granicach wynosi około 50%. Na podobnym poziomie (blisko 8%) występowały dopływy w przedziałach od 500 m 3 d -1 do 600 m 3 d -1 oraz od 700 m 3 d -1 do 800 m 3 d -1. Przedstawiony histogram jest wykonany dla dopływów, które wystąpiły w okresie badawczym 2003 2005, natomiast przyjmując inny okres badawczy, należy wraz ze zmieniającymi się dopływami ścieków histogram zmodyfikować w odniesieniu do nowych ilości dopływających ścieków. 108 WNIOSKI Na podstawie przeprowadzonej analizy dynamiki dopływających ścieków do oczyszczalni w Głogowie Małopolskim latach 2003 2005 sformułowano następujące wnioski i spostrzeżenia: 1. Średni dopływ ścieków do oczyszczalni w roku 2003 wyniósł 657,3 m 3 d -1, w roku 2004 dopływało średnio 1317,2 m 3 d -1, a w roku 2005 1485,4 m 3 d -1. W roku 2004 odnotowano ponad 100% większy dopływ w porównaniu do roku 2003, natomiast w roku 2005 wzrost ten wyniósł około 13%. Wzrost ilości dopływających ścieków związany jest z rozbudową sieci kanalizacyjnej oraz podłączaniem kolejnych gospodarstw. 2. W roku 2003 i 2004 nie odnotowano dużej nierównomierności dopływu ścieków w poszczególnych dniach tygodnia. W roku 2003 wahania dopływów ścieków były nieznaczne i wyniosły od 626,9 m 3 d -1 do 703,1 m 3 d -1. W roku 2004 dopływ ścieków wahał się w granicach od 1269,1 m 3 d -1 do 1347,3 m 3 d -1. W roku 2005 odnotowano zwiększoną nierównomierność dopływu na poziomie blisko 200 m 3 pomiędzy dopływem w 1348,3 m 3 d -1 (środy) i 1548,6 m 3 d -1 (niedziele). 3. Najczęściej pojawiające się dopływy ścieków mieszczą się w przedziałach 1100 m 3 d -1 a 1200 m 3 d -1 oraz pomiędzy 1200 m 3 d -1 a 1300 m 3 d -1. Prawdopodobieństwo odczytane z dystrybuanty empirycznej pojawienia się dopływu w tych granicach wynosi około 50%. 4. W przedmiotowej oczyszczalni ścieków zdarzały się incydentalnie dopływy ścieków znacznie przekraczające dopływy średnie. Wynosiły one ponad 2700 m 3 d -1. Prawdopodobnie były one wynikiem dopływu wód infiltracyjnych

Dynamika dopływu ścieków i przypadkowych w okresie dużych opadów atmosferycznych oraz roztopów wiosennych. Jednak tak wysokie dopływy zdarzyły się w około 0,8% przypadków. BIBLIOGRAFIA Bugajski P., Kaczor G. Struktura zużycia zimnej i ciepłej wody w gospodarstwie jednorodzinnym. Infrastruktura i Ekologia Terenów Wiejskich 2/2005. PAN o/kraków, Komisja Technicznej Infrastruktury Wsi, 2005, s. 17 26. Chotkowski W., Lis G. Krótkoterminowe prognozowanie dopływu ścieków do oczyszczalni na podstawie ilości zużywanej wody. Gaz, Woda i Technika Sanitarna 5/2006. Warszawa 2006, s. 13 18. Henze M., Harremoës P., Jansen J., Arvin E. Wastewater Treatment. Biological and Chemical Processes. Springer Verlag. London Paris Tokyo 2000. Kaczor G. Analiza dynamiki dopływu ścieków z wiejskich systemów kanalizacyjnych. Rozprawa doktorska opracowana w Katedrze Zaopatrzenia Osiedli w Wodę i Kanalizacji Akademii Rolniczej w Krakowie 2000, maszynopis. Kluba P. Analiza zużycia wody w wodociągu grupowym w gminie Drwinia. Praca Inżynierska wykonana w Katedrze Zaopatrzenia Osiedli w Wodę i Kanalizacji, 2006, maszynopis. Pawełek J., Kaczor G., Bergel T. Zagadnienia ilościowo-jakościowe ścieków bytowych odprowadzanych wiejskimi systemami kanalizacyjnymi. Ogólnopolska konferencja Naukowo-Techniczna pt. Kanalizacja wsi stan obecny, perspektywy rozwoju. Poznań Puszczykowo, luty 2004 r., s 1 24. Poradnik eksploatatora oczyszczalni ścieków. Praca zbiorowa. Polskie Zrzeszenie Inżynierów i Techników Sanitarnych Odział w Poznaniu, 1997. Dr inż. Piotr Bugajski Katedra Zaopatrzenia Osiedli w Wodę i Kanalizacji Wydział Inżynierii Środowiska i Geodezji Akademia Rolnicza w Krakowie Al. Mickiewicza 24/28 30-059 Kraków tel. (012) 632-57-88 pbugajsk@ar.krakow.pl Recenzent: Prof. dr hab. Stanisław Węglarczyk 109